Julian Kirchner

Dr. Julian Kirchner


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2018 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
JKJulian Kirchner
Julian Kirchner
LSLino M. Sawicki
Lino M. Sawicki
FNFelix Nensa
Felix Nensa
BSBenedikt Schaarschmidt
Benedikt Schaarschmidt
Henning ReisHenning Reis
Henning Reis
PHPhilipp Heusch
Philipp Heusch

11 June 2021 in Cancers
Verified
Journal Article
Open access
PDF file
LULale Umutlu
Lale Umutlu
JKJulian Kirchner
Julian Kirchner
NBNils Martin Bruckmann
Nils Martin Bruckmann
JMJanna Morawitz
Janna Morawitz
GAGerald Antoch
Gerald Antoch
Katja Pinker-DomenigKatja Pinker-Domenig
Katja Pinker-Domenig
Background: This study investigated the performance of simultaneous 18F-FDG PET/MRI of the breast as a platform for comprehensive radiomics analysis for breast cancer subtype analysis, hormone receptor status, proliferation rate and lymphonodular and distant metastatic spread. Methods: One hundred and twenty-four patients underwent simultaneous 18F-FDG PET/MRI. Breast tumors were segmented and radiomic features were extracted utilizing CERR software following the IBSI guidelines. LASSO regression was employed to select the most important radiomics features prior to model development. Five-fold cross validation was then utilized alongside support vector machines, resulting in predictive models for various combinations of imaging data series. Results: The highest AUC and accuracy for differentiation between luminal A and B was achieved by all MR sequences (AUC 0.98; accuracy 97.3). The best results in AUC for prediction of hormone receptor status and proliferation rate were found based on all MR and PET data (ER AUC 0.87, PR AUC 0.88, Ki-67 AUC 0.997). PET provided the best determination of grading (AUC 0.71), while all MR and PET analyses yielded the best results for lymphonodular and distant metastatic spread (0.81 and 0.99, respectively). Conclusion: 18F-FDG PET/MRI enables comprehensive high-quality radiomics analysis for breast cancer phenotyping and tumor decoding, utilizing the perks of simultaneously acquired morphologic, functional and metabolic data.

29 March 2022 in Cancers
Verified
Journal Article
Open access
PDF file
LULale Umutlu
Lale Umutlu
JKJulian Kirchner
Julian Kirchner
NBNils-Martin Bruckmann
Nils-Martin Bruckmann
JMJanna Morawitz
Janna Morawitz
GAGerald Antoch
Gerald Antoch
Katja Pinker-DomenigKatja Pinker-Domenig
Katja Pinker-Domenig
Background: The aim of this study was to assess whether multiparametric 18F-FDG PET/MRI-based radiomics analysis is able to predict pathological complete response in breast cancer patients and hence potentially enhance pretherapeutic patient stratification. Methods: A total of 73 female patients (mean age 49 years; range 27–77 years) with newly diagnosed, therapy-naive breast cancer underwent simultaneous 18F-FDG PET/MRI and were included in this retrospective study. All PET/MRI datasets were imported to dedicated software (ITK-SNAP v. 3.6.0) for lesion annotation using a semi-automated method. Pretreatment biopsy specimens were used to determine tumor histology, tumor and nuclear grades, and immunohistochemical status. Histopathological results from surgical tumor specimens were used as the reference standard to distinguish between complete pathological response (pCR) and noncomplete pathological response. An elastic net was employed to select the most important radiomic features prior to model development. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated for each model. Results: The best results in terms of AUCs and NPV for predicting complete pathological response in the entire cohort were obtained by the combination of all MR sequences and PET (0.8 and 79.5%, respectively), and no significant differences from the other models were observed. In further subgroup analyses, combining all MR and PET data, the best AUC (0.94) for predicting complete pathologic response was obtained in the HR+/HER2− group. No difference between results with/without the inclusion of PET characteristics was observed in the TN/HER2+ group, each leading to an AUC of 0.92 for all MR and all MR + PET datasets. Conclusion: 18F-FDG PET/MRI enables comprehensive high-quality radiomics analysis for the prediction of pCR in breast cancer patients, especially in those with HR+/HER2− receptor status.

22 February 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JKJulian Kirchner
Julian Kirchner
LSLino Morris Sawicki
Lino Morris Sawicki
SSSaravanabavaan Suntharalingam
Saravanabavaan Suntharalingam
JGJohannes Grueneisen
Johannes Grueneisen
VRVerena Ruhlmann
Verena Ruhlmann
LULale Umutlu
Lale Umutlu
To evaluate the diagnostic feasibility of an ultra-fast 18F-FDG PET/MRI protocol, including T2-w and contrast-enhanced T1-w imaging as well as metabolic assessment (PET) in comparison to 18F-FDG PET/CT and CT for whole-body staging of female patients with suspected recurrence of pelvic malignancies. 43 female patients with suspected tumor recurrence were included in this study. Suspicion was based on clinical follow-up and abnormal findings on imaging follow-up. All patients underwent a PET/CT and a subsequent PET/MRI examination. Two readers were asked to evaluate ultra-fast PET/MRI, PET/CT as well as CT datasets of PET/CT separately for suspect lesions regarding lesion count, lesion localization and lesion characterization. Statistical analyses were performed both, on a per-patient and a per-lesion basis. Tumor relapse was present in 38 of the 43 patients. Based on CT readings 25/38 tumor relapses were correctly identified. PET/CT enabled correct identification of 37/38 patients, PET/MRI correctly identified 36 of the 38 patients with recurrent cancer. On a lesion-based analysis PET/MRI enabled the correct detection of more lesions, comprising a lesion-based sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of 50%, 58%, 76%, 31%, and 53% for CT, 97%, 83%, 93%, 94%, and 92% for PET/CT and 98%, 83%, 94%, 94%, and 94% for PET/MRI, respectively. Mean scan duration of ultra-fast PET/MRI, PET/CT and whole-body CT amounted to 18.5 ± 1 minutes, 18.2 ± 1 minutes and 3.5 minutes, respectively. Ultra-fast PET/MRI provides equivalent diagnostic performance and examination time when compared to PET/CT and superior diagnostic performance to CT in restaging female patients suspected to have recurrent pelvic cancer.

6 July 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JKJulian Kirchner
Julian Kirchner
LSLino M. Sawicki
Lino M. Sawicki
CDCornelius Deuschl
Cornelius Deuschl
JGJohannes Grüneisen
Johannes Grüneisen
KBKarsten Beiderwellen
Karsten Beiderwellen
LULale Umutlu
Lale Umutlu
To evaluate the added value of the application of the liver-specific contrast phase of Gadobenate dimeglumine (Gd-BOPTA) for detection and characterization of liver lesions in 18F-FDG PET/MRI. 41 patients with histologically confirmed solid tumors and known / suspected liver metastases or not classifiable lesions in 18F-FDG PET/CT were included in this study. All patients underwent a subsequent Gd-BOPTA enhanced 18F-FDG PET/MRI examination. MRI without liver-specific contrast phase (MRI1), MRI with liver-specific contrast phase (MRI2), 18F-FDG PET/MRI without liver-specific contrast phase (PET/MRI1) and with liver-specific contrast phase (PET/MRI2) were separately evaluated for suspect lesions regarding lesion dignity, characterization, conspicuity and confidence. PET/MRI datasets enabled correct identification of 18/18 patients with malignant lesions; MRI datasets correctly identified 17/18 patients. On a lesion-based analysis PET/MRI2 provided highest accuracy for differentiation of lesions into malignant and benign lesions of 98% and 100%. Respective values were 95% and 100% for PET/MRI1, 93% and 96% for MRI2 and 91% and 93% for MRI1. Statistically significant higher diagnostic confidence was found for PET/MRI2 and MRI2 datasets compared to PET/MRI1 and MRI1, respectively (p < 0.001). The application of the liver-specific contrast phase in 18F-FDG PET/MRI further increases the diagnostic accuracy and diagnostic confidence for correct assessment of benign and malignant liver lesions.

1 March 2021 in European Journal of Radiology
Verified
Journal Article
Closed access
JMJanna Morawitz
Janna Morawitz
JKJulian Kirchner
Julian Kirchner
JLJ. Lakes
J. Lakes
NBN.M. Bruckmann
N.M. Bruckmann
EME. Mamlins
E. Mamlins
LSL.M. Sawicki
L.M. Sawicki