Mammalian cell analysis is essential in the context of both fundamental studies and clinical applications. Among the various techniques available for cell analysis, electrochemiluminescence (ECL) has attracted significant attention due to its integration of both electrochemical and spectroscopic methods. In this review, we summarize recent advances in the ECL-based systems developed for mammalian cell analysis. The review begins with a summary of the developments in luminophores that opened the door to ECL applications for biological samples. Secondly, ECL-based imaging systems are introduced as an emerging technique to visualize single-cell morphologies and intracellular molecules. In the subsequent section, the ECL sensors developed in the past decade are summarized, the use of which made the highly sensitive detection of cell-derived molecules possible. Although ECL immunoassays are well developed in terms of commercial use, the sensing of biomolecules at a single-cell level remains a challenge. Emphasis is therefore placed on ECL sensors that directly detect cellular molecules from small portions of cells or even single cells. Finally, the development of bipolar electrode devices for ECL cell assays is introduced. To conclude, the direction of research in this field and its application prospects are described.
We have developed an LSI-based amperometric sensor called “Bio-LSI” with 400 measurement points as a platform for electrochemical bio-imaging and multi-point biosensing. The system is comprised of a 10.4 mm × 10.4 mm CMOS sensor chip with 20 × 20 unit cells, an external circuit box, a control unit for data acquisition, and a DC power box. Each unit cell of the chip contains an operational amplifier with a switched-capacitor type I–V converter for in-pixel signal amplification. We successfully realized a wide dynamic range from ±1 pA to ±100 nA with a well-organized circuit design and operating software. In particular, in-pixel signal amplification and an original program to control the signal read-out contribute to the lower detection limit and wide detection range of Bio-LSI. The spacial resolution is 250 μm and the temporal resolution is 18–125 ms/400 points, which depends on the desired current detection range. The coefficient of variance of the current for 400 points is within 5%. We also demonstrated the real-time imaging of a biological molecule using Bio-LSI. The LSI coated with an Os–HRP film was successfully applied to the monitoring of the changes of hydrogen peroxide concentration in a flow. The Os–HRP-coated LSI was spotted with glucose oxidase and used for bioelectrochemical imaging of the glucose oxidase (GOx)-catalyzed oxidation of glucose. Bio-LSI is a promising platform for a wide range of analytical fields, including diagnostics, environmental measurements and basic biochemistry.
In this study, we developed bipolar electrochemical microscopy (BEM) using a closed bipolar electrode (cBPE) array with an electrochemiluminescence (ECL) detecting system. Because cBPEs are not directly connected to a detector, high spatio-temporal resolution imaging can be achieved by fabricating a microelectrode array in which each electrode point is arranged in a short interval. A cBPE array with individual cBPEs arranged in 41 μm intervals was successfully fabricated by depositing gold in the pores of a track-etched membrane using electroless plating. Using BEM with the cBPE array, which has a higher density of electrode points than the conventional multi-electrode array, we effectively demonstrated the imaging of [Fe(CN)6]3− diffusion and the respiratory activity of MCF-7 spheroids with high spatio-temporal resolution.
Here, we report the development of an electrochemical detection method for endotoxin based on the Limulus amebocyte lysate (LAL) assay. A mixture of LAL reagent and endotoxin sample solution was incubated for 1 h. The endotoxin activated a cascade reaction of zymogens contained in the LAL to generate p-nitroaniline (pNA) which was then electrochemically detected by differential pulse voltammetry (DPV). The generated pNA gave a clear peak at –0.75 V vs. silver/silver chloride (Ag/AgCl), which increased with the concentration of endotoxin in the LAL assay solution. This DPV detection was performed using an electrode chip device fabricated from a diamond-like carbon-coated glass substrate. This chip device could detect as low as 10 endotoxin units l−1 at room temperature within 1 h. This novel electrochemical method for the detection of endotoxin appears promising for the development of compact, low-cost and easy-to-use sensors for on-site monitoring of potentially contaminated medical supplies, including dialysis fluid, transplanted tissue and culture medium for assisted reproduction.
We have developed a large-scale integrated (LSI) complementary metal-oxide semiconductor (CMOS)-based amperometric sensor array system called “Bio-LSI” as a platform for electrochemical bio-imaging and multi-point biosensing with 400 measurement points. In this study, we newly developed a Bio-LSI chip with a light-shield structure and a mode-selectable function with the aim of extending the application range of Bio-LSI. The light shield created by the top metal layer of the LSI chip significantly reduces the noise generated by the photocurrent, whose value is less than 1% of the previous Bio-LSI without the light shield. The mode-selectable function enables the individual operation of 400 electrodes in off, electrometer, V1, and V2 mode. The off-mode cuts the electrode from the electric circuit. The electrometer-mode reads out the electrode potential. The V1-mode and the V2-mode set the selected sensor electrode at two different independent voltages and read out the current. We demonstrated the usefulness of the mode-selectable function. First, we displayed a dot picture based on the redox reactions of 2.0 mM ferrocenemethanol at 400 electrodes by applying two different independent voltages using the V1 and V2 modes. Second, we carried out a simultaneous detection of O2 and H2O2 using the V1 and V2 modes. Third, we used the off and V1 modes for the modification of the osmium-polyvinylpyridine gel polymer containing horseradish peroxidase (Os-HRP) at the selected electrodes, which act as sensors for H2O2. These results confirm that the advanced version of Bio-LSI is a promising tool that can be applied to a wide range of analytical fields.