The area of left ventricular (LV) pressure–strain loop (PSL) is used as an index of regional myocardial work. The purpose of the present work is to compare the main segmental PSL markers and the derived global work indices, when they are calculated using an estimated pressure signal or an observed pressure signal. In nine patients implanted with a bi-ventricular pace-maker (CRT), LV pressure was invasively measured in five conditions: CRT-off, LV-pacing, right ventricular-pacing and two different CRT-pacing. For each condition, systolic blood pressure was measured by brachial artery cuff-pressure and transthoracic echocardiography loops were recorded simultaneously. The error and relative root mean square error (rRMSE) between measured and estimated pressure were calculated for each patient and each configuration. Correlation coefficient (R2) and Bland–Altman (BA) analysis were performed for PSL area and work indices. A total of 43 different haemodynamic conditions were compared (774 segmental PSL). The global rRMSE between estimated and measured LV-pressure was 12.3 mmHg. The estimated and measured segmental LV-PSL were strongly correlated, with an R2 of 0.98. BA analysis shows that the mean bias for the estimation of segmental LV-PSL area is 86.0 mmHg.%. A significant bias effect with linearly increasing error with pressure values is observed. R2 ≥ 0.88 and a mean bias in BA analysis ≤41.4 mmHg.% was observed for the estimation of global myocardial work indices. The non-invasive estimation for LV pressure–strain loop area and the global myocardial work indices obtained from LV-PSL strongly correlates with invasive measurements.
Objective. Neural signals along the vagus nerve (VN) drive many somatic and autonomic functions. The clinical interest of VN stimulation (VNS) is thus potentially huge and has already been demonstrated in epilepsy. However, side effects are often elicited, in addition to the targeted neuromodulation. Approach. This review examines the state of the art of VNS applied to two emerging modulations of autonomic function: heart failure and obesity, especially morbid obesity. Main results. We report that VNS may benefit from improved stimulation delivery using very advanced technologies. However, most of the results from fundamental animal studies still need to be demonstrated in humans.
9 November 2015 in IEEE Transactions on Biomedical Engineering
Goal: The goal of this paper is to propose a model-based control design framework, adapted to the development of control modules for medical devices. A particular example is presented in which instantaneous heart rate is regulated in real-time, by modulating, in an adaptive manner, the current delivered to the vagus nerve by a neuromodulator. Methods: The proposed framework couples a control module, based on a classical PI controller, a mathematical model of the medical device, and a physiological model representing the cardiovascular responses to vagus nerve stimulation (VNS). In order to analyze and evaluate the behavior of the device, different control parameters are tested on a “virtual population,” generated with the model, according to the Latin Hypercube sampling method. In particular, sensitivity analyses are applied for the identification of a domain of interest in the space of the control parameters. The obtained control parameter domain has been validated in an experimental evaluation on six sheep. Results: A range of control parameters leading to accurate results was successfully estimated by the proposed model-based design method. Experimental evaluation of the control parameters inside such a domain led to the best compromise between accuracy and time response of the VNS control. Conclusion: The feasibility and usefulness of the proposed model-based design method were shown, leading to a functional, real-time closed-loop control of the VNS for the regulation of heart rate.
The role of modelling and simulation in the systemic analysis of living systems is now clearly established. Emerging disciplines, such as systems biology, and worldwide research actions, such as the Physiome Project or the Virtual Physiological Human, are based on an intensive use of modelling and simulation methodologies and tools. One of the key aspects in this context is to perform an efficient integration of various models representing different biological or physiological functions, at different resolutions, spanning through different scales. This paper presents a multiformalism modelling and simulation environment (M2SL) that has been conceived to ease model integration. A given model is represented as a set of coupled and atomic model components that may be based on different mathematical formalisms with heterogeneous structural and dynamical properties. A co-simulation approach is used to solve these hybrid systems. The pioneering model of the overall regulation of the cardiovascular system proposed by Guyton and co-workers in 1972 has been implemented under M2SL and a pulsatile ventricular model based on a time-varying elastance has been integrated in a multi-resolution approach. Simulations reproducing physiological conditions and using different coupling methods show the benefits of the proposed environment.