Albert Chong

Albert Chong

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2021 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
PDF file
ACAlbert Chong
Albert Chong
HMHadi Mirgolbabaee
Hadi Mirgolbabaee
Zhonghua SunZhonghua Sun
Zhonghua Sun
LVLennart van de Velde
Lennart van de Velde
SJShirley Jansen
Shirley Jansen
EJErik Groot Jebbink
Erik Groot Jebbink
Purpose: To compare the flow patterns and hemodynamics of the AFX stent-graft and the covered endovascular reconstruction of aortic bifurcation (CERAB) configuration using laser particle image velocimetry (PIV) experiments. Materials and Methods: Two anatomically realistic aortoiliac phantoms were constructed using polydimethylsiloxane polymer. An AFX stent-graft with a transparent cover made with a new method was inserted into one phantom. A CERAB configuration using Atrium’s Avanta V12 with transparent covers made with a previously established method was inserted into the other phantom, both modified stent-grafts were suitable for laser PIV, enabling visualization of the flow fields and quantification of time average wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT). Results: Disturbed flow was observed at the bifurcation region of the AFX, especially at the end systolic velocity (ESV) time-point where recirculation was noticeable due to vortical flow. In contrast, predominantly unidirectional flow was observed at the CERAB bifurcation. These observations were confirmed by the quantified hemodynamic results from PIV analysis where mean TAWSS of 0.078 Pa (range: 0.009–0.242 Pa) was significantly lower in AFX as compared with 0.229 Pa (range: 0.013–0.906 Pa) for CERAB (p<0.001). Mean OSI of 0.318 (range: 0.123–0.496) in AFX was significantly higher than 0.252 (range: 0.055–0.472) in CERAB (p<0.001). Likewise, mean RRT of 180 Pa−1 (range: 9–3603 Pa−1) in AFX was also significantly higher than 88 Pa−1 (range: 2–840 Pa−1) in CERAB (p=0.0086). Conclusion: In this in vitro study, the flow pattern of a modified AFX stent-graft was found to be more disturbed especially at the end systolic phase, its hemodynamic outcomes less desirable than CERAB configuration. Clinical Relevance: While the AFX stent-graft has an advantage over the CERAB configuration in eliminating radial mismatch, and maintaining the anatomical bifurcation for future endovascular intervention, this in vitro study revealed that the associated lower TAWSS, higher OSI and RRT may predispose to thrombosis and are, thus, less desirable as compared to a CERAB configuration. Further investigation is warranted to confirm whether these findings translate into the clinical setting.

1 May 2017 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
ACAlbert Chong
Albert Chong
BDBarry J. Doyle
Barry J. Doyle
SJShirley Jansen
Shirley Jansen
SPStefan Ponosh
Stefan Ponosh
JCJulien Cisonni
Julien Cisonni
Zhonghua SunZhonghua Sun
Zhonghua Sun

17 February 2020 in Artificial Organs
Verified
Journal Article
Open access
PDF file
ACAlbert Chong
Albert Chong
Zhonghua SunZhonghua Sun
Zhonghua Sun
LVLennart van de Velde
Lennart van de Velde
SJShirley Jansen
Shirley Jansen
MVMichel Versluis
Michel Versluis
EJErik Groot Jebbink
Erik Groot Jebbink
Having physiological correct flow waveforms is a key feature for experimental studies of blood flow, especially in the process of developing and testing a new medical device such as stent, mechanical heart valve, or any implantable medical device that involves circulation of blood through the device. It is also a critical part of a perfusion system for cardiopulmonary bypass and extracorporeal membrane oxygenation procedures. This study investigated the feasibility of a novel roller pump for use in experimental flow phantoms. Flow rates of carotid flow profile measured directly with the ultrasonic flow meter matched well with the reference flow rates programmed into the machine with similarity index of 0.97 and measured versus programmed flow rates at specific time‐points of peak systolic velocity (PSV): 0.894 vs 0.880, end systolic velocity (ESV): 0.333 vs 0.319, and peak diastolic velocity (PDV): 0.514 vs 0.520 L/min. Flow rates derived from video analysis of the pump motion for carotid, suprarenal, and infrarenal flows also matched well with references with similarity indices of 0.99, 0.99, and 0.96, respectively. Measured flow rates (mean/standard deviation) at PSV, ESV, and PDV time‐points for carotid: 0.883/0.016 vs 0.880, 0.342/0.007 vs 0.319, and 0.485/0.009 vs 0.520; suprarenal: 3.497/0.014 vs 3.500, 0.004/0.003 vs 0, and 1.656/0.073 vs 1.453; infrarenal: 4.179/0.024 vs 4.250, −1.147/0.015 vs −1.213, and 0.339/0.017 vs 0.391 L/min, respectively. The novel roller pump is suitable for benchtop testing of physiological flow.

24 September 2025 in Research Square
Verified
Preprint
Open access
PDF file
Hwa Liang LeoHwa Liang Leo
Hwa Liang Leo
ACAlbert Chong
Albert Chong
DKDhayananth Kanagarajan
Dhayananth Kanagarajan
Pneumatic compression devices are used across therapeutic, diagnostic, surgical, and sports medicine applications to improve vascular function, lymphatic drainage, and circulation. However, there is a lack of consolidated guidance on safe and effective cuff pressures and inflation durations, which are critical parameters for both clinical safety and device design. This systematic review aims to identify and summarize the pressure levels and inflation cycles employed in peer-reviewed studies, providing valuable insights for biomedical engineers and clinicians developing and using such technologies. A comprehensive literature search was conducted in PubMed, Scopus, and ScienceDirect for articles published between 2000 and March 2025. Of 12,375 articles identified, 120 studies met the eligibility criteria. Data were extracted on device type, anatomical location, pressure settings, inflation/deflation durations, and clinical context. Findings revealed a wide variability in pressure settings across applications, with therapeutic devices employing pressures ranging from 30 to 120 mmHg, while surgical tourniquets exceeded 200 mmHg. Inflation durations ranged from a few seconds to 45 minutes depending on the context. Despite widespread use, few studies referenced standardized safety thresholds. This review highlights the urgent need for harmonized pressure-duration guidelines and serves as a reference point for engineers designing next-generation pneumatic compression systems.