Background: One of the rare complications of primary total knee arthroplasty is intra-operative fracture. Intra-operative fracture during revision knee arthroplasty has been well-documented but there is limited literature on fractures occurring during primary knee arthroplasty. We conducted a systematic review of the literature to compare and contrast the various studies to clearly define the predisposing factors, incidence, and characteristics of the fracture itself and to arrive at a consensus on the management and prevention of intra-operative fractures during primary knee arthroplasty. Methods: The PubMed/Medline, Cochrane, Scopus and Embase databases were searched using keywords “intra-operative fracture”, “distal femoral fracture”, “tibial fracture”, “patella fracture” and “primary total knee arthroplasty”. A total of 158 articles were retrieved and after further filtration and exclusion processing, 10 articles that evaluated intra-operative fractures in primary total knee arthroplasty were included for the review. Results: The reported incidence of intra-operative fractures varied from 0.2% to 4.4%. A higher incidence in female patients with a male to female ratio of 0.4 was reported. Posterior stabilized (PS) total knee arthroplasty was associated with higher risk of intra-operative femoral fractures by many authors in this review. Timing of occurrence and location of the intra-operative fractures can vary widely, with femoral fractures occurring more commonly during bone preparation, trialing and impaction of the final implant and tibial fractures occurring during preparation for the tibial keel and impaction of the tibial component. Conclusions: Intra-operative fractures during primary total knee arthroplasty are rare with higher risk associated with osteoporosis, rheumatoid arthritis, advanced age, female gender, chronic steroid use, metabolic bone disorders, PS type of femoral implant and difficult surgical exposure of the knee joint due to severe deformities. A plethora of management options have been utilized according to surgeon preference. Standard principles of fracture fixation and arthroplasty principles should be followed to achieve stable internal fixation and any unstable fracture site should be bypassed with the utilization of stemmed components. Satisfactory radiographic and functional outcome can be expected with appropriate treatment.
Purpose: To systematically evaluate the clinical outcomes of superior capsular reconstruction (SCR) using the long head of the biceps tendon for irreparable massive rotator cuff tears. Methods: Multiple electronic databases were searched for studies treating massive and/or irreparable rotator cuff tears with SCR using the biceps tendon while retaining its proximal attachment to the superior glenoid. A PRISMA (Preferred Reporting Items for Systematic Reviews and Meta‐analyses) flowchart was created. All the included studies were assessed for quality with the Modified Coleman Methodology Score. Multiple variables including patient demographic characteristics, functional scores, visual analog scale (VAS) scores, and complications were extracted and analyzed. Results: Seven studies were included in this review, with a total of 133 patients. The age range of patients was 39 to 82 years, and the duration of follow‐up ranged from 6 to 40.7 months. Various validated scoring systems were used for functional outcome evaluation in all studies; all of them showed postoperative improvement greater than the minimal clinically important difference. The VAS score improvement ranged from 3.8 to 7.1. Five studies reported improvement in shoulder forward elevation, with a range of 22° to 95°. Three studies reported retear rates of 21%, 37%, and 66% on postoperative magnetic resonance imaging scans. Two studies reported complications, with the first study reporting revision surgery in 4 of 35 patients and the second study reporting 1 infection and 1 case of deltoid detachment (open procedure) among 17 patients. Conclusions: SCR using the long head of the biceps tendon is a safe and effective procedure. VAS and patient‐reported outcome scores showed significant improvement with minimal short‐term complications. Level of Evidence: Level IV, systematic review of Level III and IV studies.
1 November 2020 in Journal of Clinical Orthopaedics and Trauma