Agnieszka Skoczylas

Dr. Agnieszka Skoczylas


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
Natalia BudaNatalia Buda
Natalia Buda
WKWojciech Kosiak
Wojciech Kosiak
MWMarcin Wełnicki
Marcin Wełnicki
ASAgnieszka Skoczylas
Agnieszka Skoczylas
RORobert Olszewski
Robert Olszewski
TTTudor P. Toma
Tudor P. Toma
A growing amount of evidence prompts us to update the first version of recommendations for lung ultrasound in internal medicine (POLLUS-IM) that was published in 2018. The recommendations were established in several stages, consisting of: literature review, assessment of literature data quality (with the application of QUADAS, QUADAS-2 and GRADE criteria) and expert evaluation carried out consistently with the modified Delphi method (three rounds of on-line discussions, followed by a secret ballot by the panel of experts after each completed discussion). Publications to be analyzed were selected from the following databases: Pubmed, Medline, OVID, and Embase. New reports published as of October 2019 were added to the existing POLLUS-IM database used for the original publication of 2018. Altogether, 528 publications were systematically reviewed, including 253 new reports published between September 2017 and October 2019. The new recommendations concern the following conditions and issues: pneumonia, heart failure, monitoring dialyzed patients’ hydration status, assessment of pleural effusion, pulmonary embolism and diaphragm function assessment. POLLUS-IM 2020 recommendations were established primarily for clinicians who utilize lung ultrasound in their everyday clinical work.

26 February 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Natalia BudaNatalia Buda
Natalia Buda
ASAgnieszka Skoczylas
Agnieszka Skoczylas
Marcello DemiMarcello Demi
Marcello Demi
AWAnna Wojteczek
Anna Wojteczek
Jolanta CylwikJolanta Cylwik
Jolanta Cylwik
Gino SoldatiGino Soldati
Gino Soldati
Background: This study concerns the application of lung ultrasound (LUS) for the evaluation of the significance of vertical artifact changes with frequency and pleural line abnormalities in differentiating pulmonary edema from pulmonary fibrosis. Study Design and Methods: The study was designed as a diagnostic test. Having qualified patients for the study, an ultrasound examination was performed, consistent with a predetermined protocol, and employing convex and linear transducers. We investigated the possibility of B-line artifact conversion depending on the set frequency (2 MHz and 6 MHz), and examined pleural line abnormalities. Results: The study group comprised 32 patients with interstitial lung disease (ILD) (and fibrosis) and 30 patients with pulmonary edema. In total, 1941 cineloops were obtained from both groups and analyzed. The employment of both types of transducers (linear and convex) was most effective (specificity 91%, specificity 97%, positive predictive value (PPV) 97%, negative predictive value (NPV) 91%, LR(+) 27,19, LR(−) 0.097, area under curve (AUC) = 0.936, p = 7 × 10−6). Interpretation: The best accuracy in differentiating the etiology of B-line artifacts was obtained with the use of both types of transducers (linear and convex), complemented with the observation of the conversion of B-line artifacts to Z-line.