Ivan Cruz-Aceves

Dr. Ivan Cruz-Aceves

CONACYT-Centro de Investigación en Matemáticas (CIMAT), A.C., Jalisco S/N, Col. Valenciana, Guanajuato 36000, Mexico
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FCFernando Cervantes-Sanchez
Fernando Cervantes-Sanchez
ICIvan Cruz-Aceves
Ivan Cruz-Aceves
AAArturo Hernández Aguirre
Arturo Hernández Aguirre
MHMartha A. Hernández-González
Martha A. Hernández-González
SSSergio Solorio
Sergio Solorio
This paper presents a novel method for the automatic segmentation of coronary arteries in X-ray angiograms, based on multiscale analysis and neural networks. The multiscale analysis is performed by using Gaussian filters in the spatial domain and Gabor filters in the frequency domain, which are used as inputs by a multilayer perceptron (MLP) for the enhancement of vessel-like structures. The optimal design of the MLP is selected following a statistical comparative analysis, using a training set of 100 angiograms, and the area under the ROC curve ( A z ) for assessment of the detection performance. The detection results of the proposed method are compared with eleven state-of-the-art blood vessel enhancement methods, obtaining the highest performance of A z = 0.9775 , with a test set of 30 angiograms. The database of 130 X-ray coronary angiograms has been outlined by a specialist and approved by a medical ethics committee. On the other hand, the vessel extraction technique was selected from fourteen binary classification algorithms applied to the multiscale filter response. Finally, the proposed segmentation method is compared with twelve state-of-the-art vessel segmentation methods in terms of six binary evaluation metrics, where the proposed method provided the most accurate coronary arteries segmentation with a classification rate of 0.9698 and Dice coefficient of 0.6857 , using the test set of angiograms. In addition to the experimental results, the performance in the detection and segmentation steps of the proposed method have also shown that it can be highly suitable for systems that perform computer-aided diagnosis in X-ray imaging.

1 March 2016 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
ICIvan Cruz-Aceves
Ivan Cruz-Aceves
FOFaraz Oloumi
Faraz Oloumi
RRRangaraj M. Rangayyan
Rangaraj M. Rangayyan
Juan Gabriel Avina-CervantesJuan Gabriel Avina-Cervantes
Juan Gabriel Avina-Cervantes
AHArturo Hernandez-Aguirre
Arturo Hernandez-Aguirre

4 September 2020 in Mathematics
Verified
Journal Article
Open access
PDF file
EOEmmanuel Ovalle-Magallanes
Emmanuel Ovalle-Magallanes
Juan Gabriel Avina-CervantesJuan Gabriel Avina-Cervantes
Juan Gabriel Avina-Cervantes
ICIvan Cruz-Aceves
Ivan Cruz-Aceves
JRJose Ruiz-Pinales
Jose Ruiz-Pinales
Coronary artery disease is the most frequent type of heart disease caused by an abnormal narrowing of coronary arteries, also called stenosis or atherosclerosis. It is also the leading cause of death globally. Currently, X-ray Coronary Angiography (XCA) remains the gold-standard imaging technique for medical diagnosis of stenosis and other related conditions. This paper presents a new method for the automatic detection of coronary artery stenosis in XCA images, employing a pre-trained (VGG16, ResNet50, and Inception-v3) Convolutional Neural Network (CNN) via Transfer Learning. The method is based on a network-cut and fine-tuning approach. The optimal cut and fine-tuned layers were selected following 20 different configurations for each network. The three networks were fine-tuned using three strategies: only real data, only artificial data, and artificial with real data. The synthetic dataset consists of 10,000 images (80% for training, 20% for validation) produced by a generative model. These different configurations were analyzed and compared using a real dataset of 250 real XCA images (125 for testing and 125 for fine-tuning), regarding their randomly initiated CNNs and a fourth custom CNN, trained as well with artificial and real data. The results showed that pre-trained VGG16, ResNet50, and Inception-v3 cut on an early layer and fine-tuned, overcame the referencing CNNs performance. Specifically, Inception-v3 provided the best stenosis detection with an accuracy of 0.95, a precision of 0.93, sensitivity, specificity, and F1 score of 0.98, 0.92, and 0.95, respectively. Moreover, a class activation map is applied to identify the high attention regions for stenosis detection.

23 March 2022 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
EOEmmanuel Ovalle-Magallanes
Emmanuel Ovalle-Magallanes
Juan Gabriel Avina-CervantesJuan Gabriel Avina-Cervantes
Juan Gabriel Avina-Cervantes
ICIvan Cruz-Aceves
Ivan Cruz-Aceves
JRJose Ruiz-Pinales
Jose Ruiz-Pinales

18 April 2018 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
ICIvan Cruz-Aceves
Ivan Cruz-Aceves
FCFernando Cervantes-Sanchez
Fernando Cervantes-Sanchez
MGMaria Susana Avila Garcia
Maria Susana Avila Garcia
The accurate and efficient segmentation of coronary arteries in X-ray angiograms represents an essential task for computer-aided diagnosis. This paper presents a new multiscale Gaussian-matched filter (MGMF) based on artificial neural networks. The proposed method consists of two different stages. In the first stage, MGMF is used for detecting vessel-like structures while reducing image noise. The results of MGMF are compared with those obtained using six GMF-based detection methods in terms of the area (Az) under the receiver operating characteristic (ROC) curve. In the second stage, ten thresholding methods of the state of the art are compared in order to classify the magnitude of the multiscale Gaussian response into vessel and nonvessel pixels, respectively. The accuracy measure is used to analyze the segmentation methods, by comparing the results with a set of 100 X-ray coronary angiograms, which were outlined by a specialist to form the ground truth. Finally, the proposed method is compared with seven state-of-the-art vessel segmentation methods. The vessel detection results using the proposed MGMF method achieved an Az=0.9357 with a training set of 50 angiograms and Az=0.9362 with the test set of 50 images. In addition, the segmentation results using the intraclass variance thresholding method provided a segmentation accuracy of 0.9568 with the test set of coronary angiograms.

1 September 2016 in Applied Soft Computing
Verified
Journal Article
Closed access
ICIvan Cruz-Aceves
Ivan Cruz-Aceves
AHArturo Hernandez-Aguirre
Arturo Hernandez-Aguirre
SVS. Ivvan Valdez
S. Ivvan Valdez