Wei Te Wu

Prof. Wei Te Wu


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2010 in Sensors
Verified
Journal Article
Open access
PDF file
CCChien-Hsing Chen
Chien-Hsing Chen
TTTzu-Chein Tsao
Tzu-Chein Tsao
JTJaw-Luen Tang
Jaw-Luen Tang
WWWei Te Wu
Wei Te Wu
A novel class of multi-D-shaped optical fiber suited for refractive index measurements is presented. The multi-D-shaped optical fiber was constructed by forming several D-sections in a multimode optical fiber at localized regions with femtosecond laser pulses. The total number of D-shaped zones fabricated could range from three to seven. Each D-shaped zone covered a sensor volume of 100 μm depth, 250 μm width, and 1 mm length. The mean roughness of the core surface obtained by the AFM images was 231.7 nm, which is relatively smooth. Results of the tensile test indicated that the fibers have sufficient mechanical strength to resist damage from further processing. The multi-D-shaped optical fiber as a high sensitive refractive-index sensor to detect changes in the surrounding refractive index was studied. The results for different concentrations of sucrose solution show that a resolution of 1.27 × 10−3–3.13 × 10−4 RIU is achieved for refractive indices in the range of 1.333 to 1.403, suggesting that the multi-D-shaped fibers are attractive for chemical, biological, and biochemical sensing with aqueous solutions.

23 December 2009 in Microsystem Technologies
Verified
Journal Article
Closed access
PDF file
CCChien-Hsing Chen
Chien-Hsing Chen
TTTzu-Chien Tsao
Tzu-Chien Tsao
WLWan-Yun Li
Wan-Yun Li
WSWei-Chih Shen
Wei-Chih Shen
CCChung-Wei Cheng
Chung-Wei Cheng
WWWei Te Wu
Wei Te Wu

28 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
KKKuei-Pin Kuo
Kuei-Pin Kuo
HTHsun-Heng Tsai
Hsun-Heng Tsai
CLChing-Yi Lin
Ching-Yi Lin
WWWei Te Wu
Wei Te Wu
The two aims of this study were (1) designing and developing an affordable visual reaction system for badminton training that monitors and provides instant feedback on agility; and (2) to measure and improve the footwork and movement of badminton players and output useful reference data. Ten junior high school badminton players were invited to serve as the subjects of this study. They participated in a three-week (nine sessions) training program. Training was primarily in the form of fixed or random footwork drills. Timed tests were performed before and after each session to measure the players’ agility in performing six-point and four-point footwork drills. The results were compared to the training effects calculated using dependent-sample t-tests. In addition, the long-term durability and functionality of the training system were tested. The training system was able to maintain stable and reliable training and evaluation operations for extended periods. Results showed significant improvements in the visual reaction time (p = 0.003) and agility (p = 0.001) of players. The proposed training system is an affordable option for training and monitoring, evaluating, and recording training performance. It can accurately record movement and response times and simulate competitive environments.

20 August 2009 in Sensors
Verified
Journal Article
Open access
PDF file
CHChing-Te Huang
Ching-Te Huang
Chun-Ping JenChun-Ping Jen
Chun-Ping Jen
TCTzu-Chien Chao
Tzu-Chien Chao
WWWei Te Wu
Wei Te Wu
WLWan-Yun Li
Wan-Yun Li
Lai-Kwan ChauLai-Kwan Chau
Lai-Kwan Chau
Bio-molecular recognition is detected by the unique optical properties of self-assembled gold nanoparticles on the unclad portions of an optical fiber whose surfaces have been modified with a receptor. To enhance the performance of the sensing platform, the sensing element is integrated with a microfluidic chip to reduce sample and reagent volume, to shorten response time and analysis time, as well as to increase sensitivity. The main purpose of the present study is to design grooves on the optical fiber for the FO-LPR microfluidic chip and investigate the effect of the groove geometry on the biochemical binding kinetics through simulations. The optical fiber is designed and termed as U-type or D-type based on the shape of the grooves. The numerical results indicate that the design of the D-type fiber exhibits efficient performance on biochemical binding. The grooves designed on the optical fiber also induce chaotic advection to enhance the mixing in the microchannel. The mixing patterns indicate that D-type grooves enhance the mixing more effectively than U-type grooves. D-type fiber with six grooves is the optimum design according to the numerical results. The experimental results show that the D-type fiber could sustain larger elongation than the U-type fiber. Furthermore, this study successfully demonstrates the feasibility of fabricating the grooved optical fibers by the femtosecond laser, and making a transmission-based FO-LPR probe for chemical sensing. The sensor resolution of the sensor implementing the D-type fiber modified by gold nanoparticles was 4.1 × 10-7 RIU, which is much more sensitive than that of U-type optical fiber (1.8 × 10-3 RIU).

20 January 2011 in Microsystem Technologies
Verified
Journal Article
Closed access
PDF file
WWWei Te Wu
Wei Te Wu
WSWei-Hung Shih
Wei-Hung Shih
CWChih-To Wang
Chih-To Wang

26 March 2013 in Sensors
Verified
Journal Article
Open access
PDF file
CCChien-Hsing Chen
Chien-Hsing Chen
BYBo-Kuan Yeh
Bo-Kuan Yeh
JTJaw-Luen Tang
Jaw-Luen Tang
WWWei Te Wu
Wei Te Wu
This study investigates the CO2 laser-stripped partial cladding of silica-based optic fibers with a core diameter of 400 μm, which enables them to sense the refractive index of the surrounding environment. However, inappropriate treatments during the machining process can generate a number of defects in the optic fiber sensors. Therefore, the quality of optic fiber sensors fabricated using CO2 laser machining must be analyzed. The results show that analysis of the fiber core size after machining can provide preliminary defect detection, and qualitative analysis of the optical transmission defects can be used to identify imperfections that are difficult to observe through size analysis. To more precisely and quantitatively detect fabrication defects, we included a tensile test and numerical aperture measurements in this study. After a series of quality inspections, we proposed improvements to the existing CO2 laser machining parameters, namely, a vertical scanning pathway, 4 W of power, and a feed rate of 9.45 cm/s. Using these improved parameters, we created optical fiber sensors with a core diameter of approximately 400 μm, no obvious optical transmission defects, a numerical aperture of 0.52 ± 0.019, a 0.886 Weibull modulus, and a 1.186 Weibull-shaped parameter. Finally, we used the optical fiber sensor fabricated using the improved parameters to measure the refractive indices of various solutions. The results show that a refractive-index resolution of 1.8 × 10−4 RIU (linear fitting R2 = 0.954) was achieved for sucrose solutions with refractive indices ranging between 1.333 and 1.383. We also adopted the particle plasmon resonance sensing scheme using the fabricated optical fibers. The results provided additional information, specifically, a superior sensor resolution of 5.73 × 10−5 RIU, and greater linearity at R2 = 0.999.