Jaeseok Heo

Mr. Jaeseok Heo


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Min-kyoeng KimMin-kyoeng Kim
Min-kyoeng Kim
Duckshin ParkDuckshin Park
Duckshin Park
MKMinjeong Kim
Minjeong Kim
JHJaeseok Heo
Jaeseok Heo
SPSechan Park
Sechan Park
HCHwansoo Chong
Hwansoo Chong
Use of diesel locomotives in transport is gradually decreasing due to electrification and the introduction of high-speed electric rail. However, in Korea, up to 30% of the transportation of passengers and cargo still uses diesel locomotives and diesel vehicles. Many studies have shown that exhaust gas from diesel locomotives poses a threat to human health. This study examined the characteristics of particulate matter (PM), nitrogen oxides (NOx), carbon monoxide (CO), and hydrocarbons in diesel locomotive engine exhaust. Emission concentrations were evaluated and compared with the existing regulations. In the case of PM and NOx, emission concentrations increased as engine output increased. High concentrations of CO were detected at engine start and acceleration, while hydrocarbons showed weakly increased concentrations regardless of engine power. Based on fuel consumption and engine power, the emission patterns of PM and gaseous substances observed in this study were slightly higher than the U.S. Environmental Protection Agency Tier standard and the Korean emission standard. Continuous monitoring and management of emissions from diesel locomotives are required to comply with emission standards. The findings of this study revealed that emission factors varied based on fuel consumption, engine power, and actual driving patterns. For the first time, a portable emission measurement system (PEMS), normally used to measure exhaust gas from diesel vehicles, was used to measure exhaust gas from diesel locomotives, and the data acquired were compared with previous results. This study is meaningful as the first example of measuring the exhaust gas concentration by connecting a PEMS to a diesel locomotive, and in the future, a study to measure driving characteristics and exhaust gas using a PEMS should be conducted.

5 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Min-kyoeng KimMin-kyoeng Kim
Min-kyoeng Kim
YJYelim Jang
Yelim Jang
JHJaeseok Heo
Jaeseok Heo
Duckshin ParkDuckshin Park
Duckshin Park
Gravel is used in railway infrastructure to reduce environmental impacts and noise, but gravel on tracks must be replaced continuously because it deforms due to wear and weathering. It is therefore necessary to review the entire railroad life cycle. In this study, an unmanned aerial vehicle (UAV) was used to measure resuspended dust over a wide area. The dust was generated from transport movements in relation to the operation of a quarry, which represents the first stage of the railway life cycle. The dust was measured at Gangwon-do quarry using a Sniffer4D module, which can provide measurements at 1 s intervals through a light scattering method and has high reliability (R2 = 0.95 for PM2.5, R2 = 0.88 for PM10). The hourly generation of fugitive dust was calculated as 2937.5 g/h for PM2.5 and 4293.2 g/h for PM10. The social cost of dust generation was calculated as KRW 36.59 billion. The amount of dust generated per hour at the quarry was ~12 times greater than that generated by the operation of a regulator as a maintenance vehicle, with the largest amount of fugitive dust generated by the washing-type vehicle. This is the first study to measure the amount of fugitive dust generated in real time at 1 s intervals by monitoring the first stage of the railroad life cycle over a wide area using a Sniffer4D module attached to a UAV. This method can be replicated for use in various studies.

5 January 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
Min-kyoeng KimMin-kyoeng Kim
Min-kyoeng Kim
Duckshin ParkDuckshin Park
Duckshin Park
MKMinjeong Kim
Minjeong Kim
JHJaeseok Heo
Jaeseok Heo
SPSechan Park
Sechan Park
HCHwansoo Chong
Hwansoo Chong
The use of diesel locomotives in transport is gradually decreasing due to electrification and the introduction of high-speed electric rails. However, in Korea, up to 30% of passenger and cargo transport still relies on diesel locomotives and vehicles. Many studies have shown that the exhaust gas from diesel locomotives poses a threat to human health. This study examined the characteristics of particulate matter (PM) in diesel locomotive engine exhaust. In a previous study, PM emissions were found to increase as the throttle was moved to a higher notch. The use of a portable emission measurement system (PEMS) in this study did not detect the highest emissions at notch 5, as is commonly found in gravimetric analyses. When comparing the mass concentrations, the notch 1 and 5 results were similar. However, at notch 8, there was a large difference between the mass concentrations collected on the filters. Further, to reduce the fine PM emitted from diesel locomotives, the ionic components, which account for the largest proportion of the total materials in fine PM, should be clearly identified. Therefore, in this study, an analysis of the weight, ionic composition, and metal components of fine PM discharged from a diesel locomotive was performed. Based on the results, Na+ (31%), Ca2+ (27%), NO3− (24%), and SO42− (13%), were the main ionic components, and the most abundant metal components being Ca (45%) and S (20%). In this study, the chemical components generated in diesel engines of other sources were compared, and as a result, different results were shown depending on the engine load and material ingredients. For the first time, a PEMS was used to measure PM from diesel vehicles, and a comparison was made with the results obtained by a gravimetric method. This is the first report of measuring PM concentrations by connecting a PEMS to a diesel locomotive, and of the distribution and characteristics of ions and heavy metals contained in the particles collected in the filter analyzed. The results indicate the importance of identifying the characteristics of fine PM emitted from a diesel locomotive and establishing an effective reduction measurement.

31 July 2025 in Toxics
Verified
Journal Article
Open access
PDF file
DLDong keun Lee
Dong keun Lee
JPJung-min Park
Jung-min Park
JJJong-Hee Jang
Jong-Hee Jang
JJJoon-sig Jung
Joon-sig Jung
Min-kyoeng KimMin-kyoeng Kim
Min-kyoeng Kim
Duckshin ParkDuckshin Park
Duckshin Park
Petrochemical complexes are spatially expansive and host diverse emission sources, making accurate monitoring of volatile organic compounds (VOCs) challenging using conventional two-dimensional methods. This study introduces Mobile-extraction Differential Optical Absorption Spectroscopy (Me-DOAS), a real-time, three-dimensional remote sensing technique for assessing benzene emissions in the Ulsan petrochemical complex, South Korea. A vehicle-mounted Me-DOAS system conducted monthly measurements throughout 2024, capturing data during four daily intervals to evaluate diurnal variation. Routes included perimeter loops and grid-based transects within core industrial zones. The highest benzene concentrations were observed in February (mean: 64.28 ± 194.69 µg/m3; geometric mean: 5.13 µg/m3), with exceedances of the national annual standard (5 µg/m3) in several months. Notably, nighttime and early morning sessions showed elevated levels, suggesting contributions from nocturnal operations and meteorological conditions such as atmospheric inversion. A total of 179 exceedances (≥30 µg/m3) were identified, predominantly in zones with benzene-handling activities. Correlation analysis revealed a significant relationship between high concentrations and specific emission sources. These results demonstrate the utility of Me-DOAS in capturing spatiotemporal emission dynamics and support its application in exposure risk assessment and industrial emission control. The findings provide a robust framework for targeted management strategies and call for integration with source apportionment and dispersion modeling tools.

JHJaeseok Heo
Jaeseok Heo
YJYelim Jang
Yelim Jang
MVMichael Versoza
Michael Versoza
GKGihwan Kim
Gihwan Kim
Duckshin ParkDuckshin Park
Duckshin Park
Many studies have found that the concentration of fine particulates in the atmosphere has increased. In particular, when using the bus, the situation in which people are exposed to relatively high concentrations of fine particulates is increasing. The purpose of this study is to reduce exposure to these potentially harmful particulates by introducing open shelters at outdoor bus stops. In order to use it as an outdoor fine particulates reduction device, a brush filter using electrostatic force (EF) was used on an experimental scale and the generation of electrostatic force, according to the material, was examined. As electrostatic force was generated, the fine particulates collection performance was about 90% efficiency. In addition, it was confirmed that the efficiency of each particle size was improved by 57% through structural improvement. Finally, through experimentation, it was confirmed that the brush module can be used for about 70 days.

MVMichael Versoza
Michael Versoza
JHJaeseok Heo
Jaeseok Heo
SKSangwon Ko
Sangwon Ko
MKMinjeong Kim
Minjeong Kim
Duckshin ParkDuckshin Park
Duckshin Park
Normal heating, ventilation, and air conditioning (HVAC) systems typically use high-efficiency particulate air (HEPA) filters, which can filter dust, various pollutants, and even bacteria and viruses from indoor air. However, since HEPA filters cannot not clean themselves and due to the nature of these microbes which can survive for long periods of time, changing these filters improperly could transmit pathogenic bacteria or viruses, and could even lead to new infections. This study indicated that these manufactured Solid Oxygen-purifying (SOP) filters have the potential to self-disinfect, filter, and inactivate aerosolized viruses. MS2 bacteriophage was used as a model virus in two different experiments. The first experiment involved aerosolization of the virus, while the second were a higher viral load using a soaking method. The SOP filters inactivated up to 99.8% of the virus particles in both experiments, provided that the density of the SOP filter was high. Thus, SOP filters could self-clean, which led to protection against airborne and aerosolized viruses by inactivating them on contact. Furthermore, SOP filters could be potentially use or addition in HVAC systems and face masks to prevent the transmission of airborne and aerosolized viruses.