Hemangioma is a common benign vascular neoplasm that closely resembles normal vessels and can be found in all organs of the human body. Vascular lesions can be classified as infantile hemangiomas or vascular malformations on the basis of their natural history, location, cellular turnover, and histologic characteristics. The magnetic resonance (MR) imaging features of vascular malformations of the central nervous system depend on the pathologic subtype. Soft-tissue vascular malformations can be categorized with combined MR imaging and MR angiography as either high- or low-flow. Osseous vascular malformations commonly demonstrate a high-signal-intensity trabecular pattern at both T1- and T2-weighted MR imaging. A group of more aggressive vascular neoplasms, including hemangioendothelioma, hemangiopericytoma, and glomus tumor, have a nonspecific appearance at MR imaging. In the liver and spleen, hemangiomas are typically hyperintense at T2-weighted MR imaging, with a centripetal filling pattern after administration of gadopentetate dimeglumine. Vascular lesions can involve several organs or systems in angiomatous syndromes. MR imaging allows characterization of a hemangioma with typical features, which vary depending on anatomic location. Familiarity with these features facilitates diagnosis and management of these anomalies.
1 October 2012 in Computer Methods and Programs in Biomedicine
In recent years, several convolutional neural network (CNN) methods have been proposed for the automated white matter lesion segmentation of multiple sclerosis (MS) patient images, due to their superior performance compared with those of other state-of-the-art methods. However, the accuracies of CNN methods tend to decrease significantly when evaluated on different image domains compared with those used for training, which demonstrates the lack of adaptability of CNNs to unseen imaging data. In this study, we analyzed the effect of intensity domain adaptation on our recently proposed CNN-based MS lesion segmentation method. Given a source model trained on two public MS datasets, we investigated the transferability of the CNN model when applied to other MRI scanners and protocols, evaluating the minimum number of annotated images needed from the new domain and the minimum number of layers needed to re-train to obtain comparable accuracy. Our analysis comprised MS patient data from both a clinical center and the public ISBI2015 challenge database, which permitted us to compare the domain adaptation capability of our model to that of other state-of-the-art methods. In both datasets, our results showed the effectiveness of the proposed model in adapting previously acquired knowledge to new image domains, even when a reduced number of training samples was available in the target dataset. For the ISBI2015 challenge, our one-shot domain adaptation model trained using only a single case showed a performance similar to that of other CNN methods that were fully trained using the entire available training set, yielding a comparable human expert rater performance. We believe that our experiments will encourage the MS community to incorporate its use in different clinical settings with reduced amounts of annotated data. This approach could be meaningful not only in terms of the accuracy in delineating MS lesions but also in the related reductions in time and economic costs derived from manual lesion labeling.