Maysa Terada

Dr. Maysa Terada

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Surface and Coatings Technology
Verified
Journal Article
Closed access
MTMaysa Terada
Maysa Terada
FQF.M. Queiroz
F.M. Queiroz
DAD.B.S. Aguiar
D.B.S. Aguiar
VAV.H. Ayusso
V.H. Ayusso
HCH. Costenaro
H. Costenaro
ICI. Costa
I. Costa

15 November 2007 in Journal of Materials Science
Verified
Journal Article
Closed access
PDF file
MTMaysa Terada
Maysa Terada
MHMarcio F. Hupalo
Marcio F. Hupalo
ICIsolda Costa
Isolda Costa
Angelo Fernando PadilhaAngelo Fernando Padilha
Angelo Fernando Padilha

19 June 2021 in Metals
Verified
Journal Article
Open access
PDF file
FMFernanda Martins
Fernanda Martins
MTMaysa Terada
Maysa Terada
ABAline F. Santos Bugarin
Aline F. Santos Bugarin
HMHercilio G. De Melo
Hercilio G. De Melo
ICIsolda Costa
Isolda Costa
The 2XXX Al alloys are characterized by their superior mechanical properties resulting from alloying elements and precipitation hardening treatments. The AA2524-T3 alloy was developed to replace the AA2024-T3 alloy in the aerospace industry. However, both alloys present many intermetallic particles (IMCs) in their microstructure, and this is the main reason for their high susceptibility to localized corrosion (such as pitting and stress corrosion cracking). Despite the similarities between these alloys (e.g., chemical composition and type of intermetallics) the literature comparing their properties is scarce and focuses mainly on their mechanical properties, not their corrosion resistances. In this investigation, the corrosion resistance of the AA2524-T3 alloy was compared to the AA2024-T3 alloy. The microstructure of both alloys was analyzed by Scanning Electron Microscopy before and after immersion in the test electrolyte, and the number and area fraction of intermetallics of each alloy was determined. The corrosion resistance of both alloys was monitored as a function of exposure time by electrochemical impedance spectroscopy and the results were fitted using electrical equivalent circuits. The AA2524-T3 alloy presented not only higher impedance values but also less corroded areas than the AA2024-T3 alloy.

29 May 2011 in Journal of Applied Electrochemistry
Verified
Journal Article
Closed access
PDF file
MTMaysa Terada
Maysa Terada
AZAngelo José de Oliveira Zimmermann
Angelo José de Oliveira Zimmermann
HSHugo Ricardo Zschommler Sandim
Hugo Ricardo Zschommler Sandim
ICIsolda Costa
Isolda Costa
Angelo Fernando PadilhaAngelo Fernando Padilha
Angelo Fernando Padilha

1 September 2006 in Materials Research
Verified
Journal Article
Open access
PDF file
MTMaysa Terada
Maysa Terada
RARenato Altobelli Antunes
Renato Altobelli Antunes
Angelo Fernando PadilhaAngelo Fernando Padilha
Angelo Fernando Padilha
HMHercilio G. De Melo
Hercilio G. De Melo
ICIsolda Costa
Isolda Costa
The resistance to localised corrosion of the full austenitic 15%Cr-15%Ni-1.2%Mo titanium stabilized stainless steel (DIN W. Nr. 1.4970) was investigated by electrochemical methods including electrochemical impedance spectroscopy (EIS), potentiodynamic polarization and potentiostatic polarization measurements in a phosphate-buffered solution (PBS). The low carbon and non-stabilized austenitic stainless steel, AISI 316L (ASTM F-138), widely used for surgical implants, was also tested for comparison. The tests were conducted at room temperature after a stable potential had been reached. After the electrochemical measurements, the surfaces of the specimens were observed using SEM to evaluate the presence of pits. Potentiodynamic polarization results showed that both steels are prone to localized corrosion. Larger pits were found on the surface of AISI 316L specimens after the electrochemical tests. EIS response has indicated the duplex structure of the passive oxides. The results showed that the electrochemical behaviour of the DIN W. Nr. 1.4970 is better than of AISI 316L steel. Therefore, their application as an implant material may be considered.

24 July 2013 in Journal of Materials Engineering and Performance
Verified
Journal Article
Closed access
PDF file
EBEverson Prado Banczek
Everson Prado Banczek
MTMaysa Terada
Maysa Terada
PRP. R. P. Rodrigues
P. R. P. Rodrigues
ICIsolda Costa
Isolda Costa