Arrays of radiofrequency coils are widely used in magnetic resonance imaging to achieve high signal-to-noise ratios and flexible volume coverage, to accelerate scans using parallel reception, and to mitigate field non-uniformity using parallel transmission. However, conventional coil arrays require complex decoupling technologies to reduce electromagnetic coupling between coil elements, which would otherwise amplify noise and limit transmitted power. Here we report a novel self-decoupled RF coil design with a simple structure that requires only an intentional redistribution of electrical impedances around the length of the coil loop. We show that self-decoupled coils achieve high inter-coil isolation between adjacent and non-adjacent elements of loop arrays and mixed arrays of loops and dipoles. Self-decoupled coils are also robust to coil separation, making them attractive for size-adjustable and flexible coil arrays.

1 June 2017 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
XYXinqiang Yan
Xinqiang Yan
XZXiaoliang Zhang
Xiaoliang Zhang
JGJohn C. Gore
John C. Gore
WGWilliam A. Grissom
William A. Grissom

9 September 2022 in NMR in Biomedicine
Verified
Journal Article
Closed access
MLMing Lu
Ming Lu
SCShuyang Chai
Shuyang Chai
HZHaoqin Zhu
Haoqin Zhu
XYXinqiang Yan
Xinqiang Yan

6 January 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
YZYue Zhu
Yue Zhu
CSCharlotte R. Sappo
Charlotte R. Sappo
WGWilliam A. Grissom
William A. Grissom
JGJohn C. Gore
John C. Gore
XYXinqiang Yan
Xinqiang Yan
Balun or trap circuits are critical components for suppressing common-mode currents flowing on the outer conductors of coaxial cables in RF coil systems for Magnetic Resonance Imaging (MRI) and Magnetic Resonance Spectroscopy (MRS). Common-mode currents affect coils’ tuning and matching, induce losses, pick up extra noise from the surrounding environment, lead to undesired cross-talk, and cause safety concerns in animal and human imaging. First proposed for microwave antenna applications, the Lattice balun has been widely used in MRI coils. It has a small footprint and can be easily integrated with coil tuning/matching circuits. However, the Lattice balun is typically a single-tuned circuit and cannot be used for multi-nuclear MRI and MRS with two RF frequencies. This work describes a dual-tuned Lattice balun design that is suitable for multi-nuclear MRI/MRS. It was first analyzed theoretically to derive component values. RF circuit simulations were then performed to validate the theoretical analysis and provide guidance for practical construction. Based on the simulation results, a dual-tuned balun circuit was built for 7T 1 H/ 23 Na MRI and bench tested. The fabricated dual-tuned balun exhibits superior performance at the Larmor frequencies of both 1 H and 23 Na, with less than 0.15 dB insertion loss and better than 17 dB common-mode rejection ratio at both frequencies.

23 February 2024 in Journal of Magnetic Resonance
Verified
Journal Article
Open access
HZHaoqin Zhu
Haoqin Zhu
QZQiang Zhang
Qiang Zhang
RLRangsong Li
Rangsong Li
YCYuanyuan Chen
Yuanyuan Chen
GZGong Zhang
Gong Zhang
XYXinqiang Yan
Xinqiang Yan
MRI is essential for evaluating and diagnosing various conditions affecting the temporomandibular joint (TMJ) and surrounding structures, as it provides highly detailed images that enable healthcare professionals to assess the joints and surroundings in great detail. While commercial MRI scanners typically come equipped with basic receive coils, such as the head receive array, RF coils tailored for specialized applications like TMJ MRI must be obtained separately. Consequently, TMJ MRI scans are often conducted using the head receive array, yet this configuration proves suboptimal due to the lack of specialized coils. In this study, we introduce a simple, low-cost, and easy-to-reproduce wireless resonator insert to enhance the quality of TMJ MRI at 1.5 T. The wireless resonator shows a significant improvement in signal-to-noise ratio (SNR) and noticeably better imaging quality than the head array alone configuration in both phantom and in vivo images.

7 April 2016 in Applied Magnetic Resonance
Verified
Journal Article
Closed access
PDF file
XYXinqiang Yan
Xinqiang Yan
LWLong Wei
Long Wei
SCSuoda Chu
Suoda Chu
RXRong Xue
Rong Xue
XZXiaoliang Zhang
Xiaoliang Zhang