Purpose: The purpose of this study was to describe a novel device that may serve as an alternative to Descemet membrane endothelial keratoplasty (DMEK) for the treatment of chronic corneal edema. Methods: The EndoArt (EyeYon Medical, Israel) is a flexible, 50-μm thin artificial endothelial layer that matches the cornea's posterior curvature and functions as a fluid barrier at the posterior stroma, replacing the diseased endothelium. Similar to a DMEK approach, it is implanted into the anterior chamber, carefully positioned on the posterior stroma, and secured using an air–gas mixture. Two patients with chronic corneal edema resulting from endothelial decompensation underwent implantation of the new artificial lamella. Results: In patient 1, the central corneal thickness (CCT) decreased from 730 μm preoperatively to 593 μm at 1 day postoperatively. In patient 2, the CCT decreased from 761 μm preoperatively to 487 μm at 1 day postoperatively. Both patients reported high satisfaction and an overall brighter visual quality. Although dislocation of the lamella occurred in both cases, the CCT was promptly restored after a repositioning procedure and remained stable at the 17-month follow-up (CCT of 526 and 457 μm for patients 1 and 2, respectively). In contrast to DMEK donor tissue, the artificial lamella is sufficiently robust to allow easy intraocular manipulation without the risk of damaging the implant. It is easily removable and does not require any immunosuppressive treatment because of its nonbiological nature. Conclusions: Implantation of the EndoArt led to rapid corneal deturgescence and CCT restoration, presenting a possible option for patients with chronic corneal edema.
29 November 2021 in European Journal of Ophthalmology
Purpose: To analyze the tomographically non-affected second eyes of keratoconus patients using the Corvis ST to detect any biomechanical abnormalities or subclinical keratoconus. Methods: In this retrospective, single-center, consecutive case series 244 eyes of 122 keratoconus patients were analyzed between November 2020 and February 2021. Fourteen fellow eyes fulfilled the inclusion criteria and showed no clinical or tomographic signs of keratoconus. Main outcome measures included best-corrected visual acuity, tomographic and biomechanical analyses using Scheimpflug imaging: Pentacam and Corvis ST (Oculus, Wetzlar, Germany). Tomographic analyses included anterior and posterior simulated keratometry, K-Max, central corneal thickness, thinnest corneal thickness, Belin/Ambrosio Ectasia Display, and the ABCD grading system. For biomechanical analyses, the corneal biomechanical index (CBI) and tomographic biomechanical index were used. Results: The mean best-corrected visual acuity was 0.01 ± 0.10 logMAR. Mean K-Max was 43.79 ± 1.12 D, mean central corneal thickness 529 ± 25 µm, mean thinnest corneal thickness 524 ± 23 µm, and mean Belin/Ambrosio Ectasia Display 1.0 ± 0.32. The mean CBI was 0.30 ± 0.21. Regular CBI values were found in six of 14 patients. The mean tomographic biomechanical index was 0.47 ± 0.22 with regular values observed in only two of 14 patients. No signs of tomographic or biomechanical abnormalities were shown in only one of 14 keratoconus fellow eyes, with regular ABCD, Belin/Ambrosio Ectasia Display, CBI and tomographic biomechanical index values. Conclusions: Tomographically normal fellow eyes of keratoconus patients are rare. In these cases, a biomechanical analysis of the cornea may help detect a subclinical keratoconus. The tomographic biomechanical index was the most sensitive index to verify a mild ectasia.
1 September 2023 in Journal of Cataract & Refractive Surgery
In this meta-analysis and systematic literature review of refractive outcomes after Descemet membrane endothelial keratoplasty (DMEK), the extent of the refractive shift and an overview of reasons for refractive shift after DMEK are provided. The PubMed library was screened for articles containing the terms “Descemet membrane endothelial keratoplasty,” “DMEK,” “Descemet membrane endothelial keratoplasty combined with cataract surgery,” “triple-DMEK” combined with “refractive outcomes,” “refractive shift,” and “hyperopic shift.” The refractive outcomes after DMEK were analyzed and compared using a fixed and random effects model. The overall mean change of the spherical equivalent outcome when compared with the preoperative value in cases of DMEK or when compared with the preoperative target refraction in cases of DMEK combined with cataract surgery was +0.43 diopters (D) (95% CI, 0.31-0.55). When DMEK is combined with cataract surgery, a target refraction of −0.5 D is recommended to achieve emmetropia. Changes in the posterior corneal curvature are identified as the main cause of the refractive hyperopic shift.
Purpose: To develop and test a parameter for early keratoconus screening by quantifying the localized epithelial thickness differences in keratoconic eyes. Methods: The cross-sectional study included 189 eyes of 116 subjects in total: 86 eyes of 54 keratoconus patients with bilateral ectasia and 40 eyes of 20 healthy subjects in the parameter-development dataset and 42 eyes of 21 keratoconus patients with asymmetric ectasia and 21 eyes of 21 healthy subjects in the parameter-validation dataset. Epithelial thickness maps were obtained using anterior segment optical coherence tomography and the inter-zonal epithelial thickness differences were calculated. The developed parameter was tested in keratoconus patients with asymmetric ectasia. Results: Compared to healthy controls, the inferior-temporal and global inter-zonal epithelial thickness differences were higher not only in eyes with tomographically significant keratoconus (median [interquartile range] of 4.42 [3.13] µm vs. 0.78 [0.42] µm, p < 0.001, and 3.05 [1.51] µm vs. 1.07 [0.26] µm, p < 0.001, respectively), but also in tomographically normal keratoconus fellow eyes (1.36 [0.85] µm vs. 0.78 [0.42] µm, p = 0.005, and 1.31 [0.32] µm vs. 1.07 [0.26] µm, p = 0.01, respectively). The inferior-temporal inter-zonal epithelial thickness differences had an area under the receiver operating characteristic curve (95% confidence interval) of 0.991 (0.972–1) for detecting tomographically significant keratoconus and 0.749 (0.598–0.901) for differentiating between tomographically normal keratoconus fellow eyes and healthy controls. Conclusions: The inter-zonal epithelial thickness differences are increased in keratoconus fellow eyes which still have a normal Scheimpflug corneal tomography, and therefore may serve as a useful parameter to detect early ectatic changes.
Purpose: The purpose of this research was to compare the ability of Scheimpflug and anterior segment optical coherence tomography (OCT) in detecting subclinical corneal edema in patients with Fuchs endothelial corneal dystrophy (FECD) without clinical corneal edema. Methods: In this single-center, consecutive case series, 47 eyes of 29 patients with FECD were analyzed. The main outcome measures were anterior/posterior keratometry and central/thinnest corneal thickness. The criteria for subclinical corneal edema were loss of regular isopachs, displacement of the thinnest point of the cornea, and presence of posterior surface depression. Tomographic analyses were performed using Scheimpflug imaging (Pentacam HR) and OCT (anterior segment swept-source optical coherence tomography). Results: The measurement of the continuous variables revealed a significant difference between the 2 devices. The anterior curvature was steeper and the posterior curvature was flatter when measured with OCT (P < 0.001). The OCT showed a lower central corneal thickness and thinnest corneal thickness (P < 0.001). The agreement between both devices to detect subclinical corneal edema was high. The interdevice reliability for loss of parallel isopachs as measured by Cohen kappa coefficient was 0.84; for the displacement of the thinnest point of the cornea, it was 0.6, and for the focal posterior corneal surface depression, it was 0.62. Subclinical corneal edema was detected in 72.3% of the patients with both devices. In only 2 cases (4.3%), subclinical corneal edema was detected by one of the devices. Conclusions: Scheimpflug and OCT imaging were both able to detect tomographic patterns of subclinical corneal edema. Therefore, both devices can help decision-making, favoring early endothelial keratoplasty in symptomatic patients with FECD without clinical corneal edema.
17 June 2024 in Graefe's Archive for Clinical and Experimental Ophthalmology
Purpose: To evaluate the biomechanical and tomographic outcomes of keratoconus patients up to four years after corneal crosslinking (CXL). Methods: In this longitudinal retrospective-prospective single-center case series, the preoperative tomographic and biomechanical results from 200 keratoconus eyes of 161 patients undergoing CXL were compared to follow-up examinations at three-months, six-months, one-year, two-years, three-years, and four-years after CXL. Primary outcomes included the Corvis Biomechanical Factor (CBiF) and five biomechanical response parameters obtained from the Corvis ST. Tomographically, the Belin-Ambrósio deviation index (BAD-D) and the maximal keratometry (Kmax) measured by the Pentacam were analyzed. Additionally, Corvis E-staging, the thinnest corneal thickness (TCT), and the best-corrected visual acuity (BCVA) were obtained. Primary outcomes were compared using a paired t-test. Results: The CBiF decreased significantly at the six-month (p < 0.001) and one-year (p < 0.001) follow-ups when compared to preoperative values. E-staging behaved accordingly to the CBiF. Within the two- to four-year follow-ups, the biomechanical outcomes showed no significant differences when compared to preoperative. Tomographically, the BAD-D increased significantly during the first year after CXL with a maximum at six-months (p < 0.001), while Kmax decreased significantly (p < 0.001) and continuously up to four years after CXL. The TCT was lower at all postoperative follow-up visits compared to preoperative, and the BCVA improved. Conclusion: In the first year after CXL, there was a temporary progression in both the biomechanical CBiF and E-staging, as well as in the tomographic analysis. CXL contributes to the stabilization of both the tomographic and biomechanical properties of the cornea up to four years postoperatively.