We analyzed antibody response patterns according to the level of disease severity in patients with novel coronavirus disease 2019 (COVID‐19) in Japan. We analyzed 611 serum specimens from 231 patients with COVID‐19 (mild, 170; severe, 31; critical, 30). Immunoglobulin M (IgM) and IgG antibodies against nucleocapsid protein (N) and spike 1 protein (S1) were detected by enzyme‐linked immunosorbent assays. The peaks of fitting curves for the optical density (OD) values of IgM and IgG antibodies against N appeared simultaneously, while those against S1 were delayed compared with N. The OD values of IgM against N and IgG against both N and S1 were significantly higher in the severe and critical cases than in the mild cases at 11 days after symptom onset. The seroconversion rates of IgG were higher than those of IgM against both N and S1 during the clinical course based on the optimal cut‐off values defined in this study. The seroconversion rates of IgG and IgM against N and S1 were higher in the severe and critical cases than in the mild cases. Our findings show that a stronger antibody response occurred in COVID‐19 patients with greater disease severity and there were low seroconversion rates of antibodies against N and S1 in the mild cases.
Introduction: Whole genome sequencing (WGS) of influenza viruses is important for preparing vaccines and coping with newly emerging viruses. However, WGS is difficult to perform using conventional next-generation sequencers in developing countries, where facilities are often inadequate. In this study, we developed a high-throughput WGS method for influenza viruses in clinical specimens with the MinION portable sequencer. Methods: Whole genomes of influenza A and B viruses were amplified by multiplex RT-PCR from 13 clinical specimens collected in Tokyo, Japan. Barcode tags for multiplex MinION sequencing were added with each multiplex RT-PCR amplicon by nested PCR with custom barcoded primers. All barcoded amplicons were mixed and multiplex sequencing using the MinION sequencer with 1D2 sequencing kit. In addition, multiplex RT-PCR amplicons generated from each clinical specimen were sequenced using the Illumina MiSeq platform to validate the performance of MinION sequencer. The accuracy, recall, and precision rates of MinION sequencing were calculated by comparing the results of variant calling in the Illumina MiSeq platform and MinION sequencer. Results: Whole genomes of influenza A and B viruses were successfully amplified by multiplex RT-PCR from 13 clinical samples. We identified 6 samples as influenza type A virus H3N2 subtype and 7 as influenza B virus Yamagata lineage using the Illumina MiSeq platform. The overall accuracy, recall, and precision rates of the MinION sequencer were, respectively 99.95%, 89.41%, and 97.88% from 1D reads and 99.97%, 93.28%, and 99.86% from 1D2 reads. Conclusion: We developed a novel WGS method for influenza A and B viruses. It is necessary to improve read accuracy and analytical tools in order to better utilize the MinION sequencer for real-time monitoring of genetic rearrangements and for evaluation of newly emerging viruses.
We report a patient with congenital Chagas disease in Japan. This report reemphasizes the role of neglected and emerging tropical diseases in the era of globalization. It also indicates the need for increased vigilance for detecting Chagas disease in non–disease-endemic countries.
A simple and accurate molecular diagnostic method for malaria is urgently needed due to the limitations of conventional microscopic examination. In this study, we demonstrate a new diagnostic procedure for human malaria using loop mediated isothermal amplification (LAMP) and the MinION™ nanopore sequencer. We generated specific LAMP primers targeting the 18S–rRNA gene of all five human Plasmodium species including two P. ovale subspecies (P. falciparum, P. vivax, P. ovale wallikeri, P. ovale curtisi, P. knowlesi and P. malariae) and examined human blood samples collected from 63 malaria patients in Indonesia. Additionally, we performed amplicon sequencing of our LAMP products using MinION™ nanopore sequencer to identify each Plasmodium species. Our LAMP method allowed amplification of all targeted 18S–rRNA genes of the reference plasmids with detection limits of 10–100 copies per reaction. Among the 63 clinical samples, 54 and 55 samples were positive by nested PCR and our LAMP method, respectively. Identification of the Plasmodium species by LAMP amplicon sequencing analysis using the MinION™ was consistent with the reference plasmid sequences and the results of nested PCR. Our diagnostic method combined with LAMP and MinION™ could become a simple and accurate tool for the identification of human Plasmodium species, even in resource-limited situations.