Hoseong Lee

Mr. Hoseong Lee

Thermal Management R&D Center, KATECH, 303 Pungse-ro, Pungse-Myun, Cheonan, 31214, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2014 in Applied Energy
Verified
Journal Article
Closed access
JAJae Hwan Ahn
Jae Hwan Ahn
HKHoon Kang
Hoon Kang
HLHoseong Lee
Hoseong Lee
HJHae Won Jung
Hae Won Jung
CBChanghyun Baek
Changhyun Baek
YKYongchan Kim
Yongchan Kim

8 March 2012 in Energies
Verified
Journal Article
Open access
PDF file
CCChung-Won Cho
Chung-Won Cho
HLHoseong Lee
Hoseong Lee
JWJong-Phil Won
Jong-Phil Won
MLMoo-Yeon Lee
Moo-Yeon Lee
The objective of this study is to investigate heating performance characteristics of a coolant source heat pump using the wasted heat from electric devices for an electric bus. The heat pump, using R-134a, is designed for heating a passengers’ compartment by using discharged energy from the coolant of electric devices, such as motors and inverters of the electric bus. The heating performance of the heat pump was tested by varying the operating parameters, such as outdoor temperature and volume flow rate of the coolant water of the electrical devices. Heating capacity, compressor work, and heating COP were measured; their behaviors with regard to the parameters were observed. Experimental results showed that heating COP increased with decrease of outdoor temperature, from 20.0 °C to 0 °C, and it observed to be 3.0 in the case of 0 °C outdoor temperature. The observed characteristics of the heating COP suggest that the heat pump is applicable as the cabin heater of an electric vehicle, which is limited by short driving range.


8 May 2020 in Symmetry
Verified
Journal Article
Open access
PDF file
Mooyeon LeeMooyeon Lee
Mooyeon Lee
JSJae-Hyeong Seo
Jae-Hyeong Seo
HLHoseong Lee
Hoseong Lee
KGKunal Garud
Kunal Garud
The objective of this study was to investigate the power generation, efficiency, and thermal stress of a thermoelectric module with leg geometry, material, segmentation, and two-stage arrangement. The effects of leg geometry, material, segmentation, and two-stage arrangement on maximum power, maximum efficiency, and maximum stress under various temperature differences and voltage load conditions were investigated. The performance parameters of the thermoelectric module were evaluated based on a numerical approach using ANSYS 19.1 commercial software. An analytical approach based on theoretical equations of the thermoelectric module was used to verify the accuracy and reliability of the numerical approach. The numerically predicted values for maximum power and maximum efficiency of the thermoelectric module were validated as ±5% and those for the maximum thermal stress of the thermoelectric module as ±7% with the corresponding calculated theoretical values. In addition, the predicted values of maximum power and maximum stress of the thermoelectric module were validated as ±2% and ±5%, respectively, with studies reported by Ma et al. and Al-Merbati et al. Of all the combinations, the single stage segmented arrangement with cylindrical leg geometry and SiGe+Bi2Te3 material was suggested as the best combination with maximum power of 0.73 W, maximum efficiency of 13.2%, and maximum thermal stress of 0.694 GPa.

21 February 2014 in Energies
Verified
Journal Article
Open access
PDF file
DLDong Hyun Lim
Dong Hyun Lim
Mooyeon LeeMooyeon Lee
Mooyeon Lee
HLHoseong Lee
Hoseong Lee
SKSung Chul Kim
Sung Chul Kim
High power and miniaturization of motors in an in-wheel drive system, which is installed inside the wheels of a vehicle, are required for directly driving the wheels. In addition, an efficient cooling system is required to ensure high driving performance and durability. This study experimentally evaluated the heat dissipation performance of a 35-kW-class large-capacity in-wheel motor equipped with an internal-circulation-type oil-cooling system that exhibits high cooling performance and can be easily miniaturized to this motor. Temperatures of the coil and stator core of cooling systems with and without a radiator were measured in real time under in-wheel motor driving conditions. It was found that operating the cooling system at a continuous-rating maximum speed without the radiator was difficult. We confirmed that under continuous-rating base speed and continuous-rating maximum speed driving conditions, the cooling system with the radiator showed thermally stable operation. Furthermore, under maximum-rating base speed and maximum-rating maximum speed driving conditions, the cooling system with the radiator provided additional driving times of approximately 22 s and 2 s, respectively.

11 May 2012 in Energies
Verified
Journal Article
Open access
PDF file
Mooyeon LeeMooyeon Lee
Mooyeon Lee
HLHoseong Lee
Hoseong Lee
HWHong-Phil Won
Hong-Phil Won
The objective of this study was to investigate the cooling performance characteristics of an electrical air conditioning system using R744 as an alternative of R-134a for a fuel cell electric vehicle. In order to analyze the cooling performance characteristics of the air conditioning system using R744 for a fuel cell electric vehicle, an electrical air conditioning system using R744 was developed and tested under various operating conditions according to both inlet air conditions of the gas cooler and evaporator and compressor speed. The cooling capacity and coefficient of performance (COP) forcooling of the tested air conditioning system were up to 6.4 kW and 2.5, respectively. In addition, the electrical air conditioning system with R744 using an inverter driven compressor showed better performance than the conventional air conditioning system with R-134a under the same operating conditions. The observed cooling performance of the developed electrical air conditioning system was found to be sufficient for cooling loads under various real driving conditions for a fuel cell electric vehicle.