Daisuke Kawahara

Dr. Daisuke Kawahara


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2021 in Reports of Practical Oncology and Radiotherapy
Verified
Journal Article
Open access
PDF file
DKDaisuke Kawahara
Daisuke Kawahara
YNYasushi Nagata
Yasushi Nagata
Background: The objective of this study was to propose an optimal input image quality for a conditional generative adversarial network (GAN) in T1-weighted and T2-weighted magnetic resonance imaging (MRI) images. Materials and methods: A total of 2,024 images scanned from 2017 to 2018 in 104 patients were used. The prediction framework of T1-weighted to T2-weighted MRI images and T2-weighted to T1-weighted MRI images were created with GAN. Two image sizes (512 × 512 and 256 × 256) and two grayscale level conversion method (simple and adaptive) were used for the input images. The images were converted from 16-bit to 8-bit by dividing with 256 levels in a simple conversion method. For the adaptive conversion method, the unused levels were eliminated in 16-bit images, which were converted to 8-bit images by dividing with the value obtained after dividing the maximum pixel value with 256. Results: The relative mean absolute error (rMAE) was 0.15 for T1-weighted to T2-weighted MRI images and 0.17 for T2-weighted to T1-weighted MRI images with an adaptive conversion method, which was the smallest. Moreover, the adaptive conversion method has a smallest mean square error (rMSE) and root mean square error (rRMSE), and the largest peak signal-to-noise ratio (PSNR) and mutual information (MI). The computation time depended on the image size. Conclusions: Input resolution and image size affect the accuracy of prediction. The proposed model and approach of prediction framework can help improve the versatility and quality of multi-contrast MRI tests without the need for prolonged examinations. Background: The objective of this study was to propose an optimal input image quality for a conditional generative adversarial network (GAN) in T1-weighted and T2-weighted magnetic resonance imaging (MRI) images. Materials and methods: A total of 2,024 images scanned from 2017 to 2018 in 104 patients were used. The prediction framework of T1-weighted to T2-weighted MRI images and T2-weighted to T1-weighted MRI images were created with GAN. Two image sizes (512 × 512 and 256 × 256) and two grayscale level conversion method (simple and adaptive) were used for the input images. The images were converted from 16-bit to 8-bit by dividing with 256 levels in a simple conversion method. For the adaptive conversion method, the unused levels were eliminated in 16-bit images, which were converted to 8-bit images by dividing with the value obtained after dividing the maximum pixel value with 256. Results: The relative mean absolute error (rMAE) was 0.15 for T1-weighted to T2-weighted MRI images and 0.17 for T2-weighted to T1-weighted MRI images with an adaptive conversion method, which was the smallest. Moreover, the adaptive conversion method has a smallest mean square error (rMSE) and root mean square error (rRMSE), and the largest peak signal-to-noise ratio (PSNR) and mutual information (MI). The computation time depended on the image size. Conclusions: Input resolution and image size affect the accuracy of prediction. The proposed model and approach of prediction framework can help improve the versatility and quality of multi-contrast MRI tests without the need for prolonged examinations.

10 August 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
DKDaisuke Kawahara
Daisuke Kawahara
NINobuki Imano
Nobuki Imano
RNRiku Nishioka
Riku Nishioka
KOKouta Ogawa
Kouta Ogawa
TKTomoki Kimura
Tomoki Kimura
YNYasushi Nagata
Yasushi Nagata
To predict grade ≥ 2 radiation pneumonitis (RP) in patients with locally advanced non-small cell lung cancer (NSCLC) using multi-region radiomics analysis. Data from 77 patients with NSCLC who underwent definitive radiotherapy between 2008 and 2018 were analyzed. Radiomic feature extraction from the whole lung (whole-lung radiomics analysis) and imaging- and dosimetric-based segmentation (multi-region radiomics analysis) were performed. Patients with RP grade ≥ 2 or < 2 were classified. Predictors were selected with least absolute shrinkage and selection operator logistic regression and the model was built with neural network classifiers. A total of 49,383 radiomics features per patient image were extracted from the radiotherapy planning computed tomography. We identified 4 features and 13 radiomics features in the whole-lung and multi-region radiomics analysis for classification, respectively. The accuracy and area under the curve (AUC) without the synthetic minority over-sampling technique (SMOTE) were 60.8%, and 0.62 for whole-lung and 80.1%, and 0.84 for multi-region radiomics analysis. These were improved 1.7% for whole-lung and 2.1% for multi-region radiomics analysis with the SMOTE. The developed multi-region radiomics analysis can help predict grade ≥ 2 RP. The radiomics features in the median- and high-dose regions, and the local intensity roughness and variation were important factors in predicting grade ≥ 2 RP.

18 February 2021 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
DKDaisuke Kawahara
Daisuke Kawahara
SOShuichi Ozawa
Shuichi Ozawa
TKTomoki Kimura
Tomoki Kimura
YNYasushi Nagata
Yasushi Nagata
Purpose: To synthesize a dual‐energy computed tomography (DECT) image from an equivalent kilovoltage computed tomography (kV‐CT) image using a deep convolutional adversarial network.Methods: A total of 18,084 images of 28 patients are categorized into training and test datasets. Monoenergetic CT images at 40, 70, and 140 keV and equivalent kV‐CT images at 120 kVp are reconstructed via DECT and are defined as the reference images. An image prediction framework is created to generate monoenergetic computed tomography (CT) images from kV‐CT images. The accuracy of the images generated by the CNN model is determined by evaluating the mean absolute error (MAE), mean square error (MSE), relative root mean square error (RMSE), peak signal‐to‐noise ratio (PSNR), structural similarity index (SSIM), and mutual information between the synthesized and reference monochromatic CT images. Moreover, the pixel values between the synthetic and reference images are measured and compared using a manually drawn region of interest (ROI).Results: The difference in the monoenergetic CT numbers of the ROIs between the synthetic and reference monoenergetic CT images is within the standard deviation values. The MAE, MSE, RMSE, and SSIM are the smallest for the image conversion of 120 kVp to 140 keV. The PSNR is the smallest and the MI is the largest for the synthetic 70 keV image.Conclusions: The proposed model can act as a suitable alternative to the existing methods for the reconstruction of monoenergetic CT images in DECT from single‐energy CT images.

1 January 2021 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
DKDaisuke Kawahara
Daisuke Kawahara
ASAkito Saito
Akito Saito
SOShuichi Ozawa
Shuichi Ozawa
YNYasushi Nagata
Yasushi Nagata

14 February 2025 in Cancer Genetics
Verified
Journal Article
Closed access
DKDaisuke Kawahara
Daisuke Kawahara
MKMisato Kishi
Misato Kishi
YKYuzuha Kadooka
Yuzuha Kadooka
KHKota Hirose
Kota Hirose
YMYuji Murakami
Yuji Murakami

1 August 2021 in British Journal of Radiology
Verified
Journal Article
Closed access
DKDaisuke Kawahara
Daisuke Kawahara
YMYuji Murakami
Yuji Murakami
STShigeyuki Tani
Shigeyuki Tani
YNYasushi Nagata
Yasushi Nagata
Objective: To propose the prediction model for degree of differentiation for locally advanced esophageal cancer patients from the planning CT image by radiomics analysis with machine learning. Methods: Data of 104 patients with esophagus cancer, who underwent chemoradiotherapy followed by surgery at the Hiroshima University hospital from 2003 to 2016 were analyzed. The treatment outcomes of these tumors were known prior to the study. The data were split into 3 sets: 57/16 tumors for the training/validation and 31 tumors for model testing. The degree of differentiation of squamous cell carcinoma was classified into two groups. The first group (Group I) was a poorly differentiated (POR) patients. The second group (Group II) was well and moderately differentiated patients. The radiomics feature was extracted in the tumor and around the tumor regions. A total number of 3480 radiomics features per patient image were extracted from radiotherapy planning CT scan. Models were built with the least absolute shrinkage and selection operator (LASSO) logistic regression and applied to the set of candidate predictors. The radiomics features were used for the input data in the machine learning. To build predictive models with radiomics features, neural network classifiers was used. The precision, accuracy, sensitivity by generating confusion matrices, the area under the curve (AUC) of receiver operating characteristic curve were evaluated. Results: By the LASSO analysis of the training data, we found 13 radiomics features from CT images for the classification. The accuracy of the prediction model was highest for using only CT radiomics features. The accuracy, specificity, and sensitivity of the predictive model were 85.4%, 88.6%, 80.0%, and the AUC was 0.92. Conclusion: The proposed predictive model showed high accuracy for the classification of the degree of the differentiation of esophagus cancer. Because of the good prediction ability of the method, the method may contribute to reducing the pathological examination by biopsy and predicting the local control. Advances in knowledge: For esophageal cancer, the differentiation of degree is the import indexes reflecting the aggressiveness. The current study proposed the prediction model for the differentiation of degree with radiomics analysis.