This work presents a novel method to assess the condition of Caenorhabditis elegans (C. elegans) through a resistance measurement of its undulatory locomotion speed inside a micro channel. As the worm moves over the electrode inside the micro channel, the length of the electrode changes, consequently behaving like a strain gauge. In this paper, the electrotaxis was applied for controlling the direction of motion of C. elegans as an external stimulus, resulting in the worm moving towards the cathode of the circuit. To confirm the proposed measurement method, a microfluidic device was developed that employs a sinusoidal channel and a thin polydimethylsiloxane (PDMS) layer with an electrode. The PDMS layer maintains a porous structure to enable the flexibility of the electrode. In this study, 6 measurements were performed to obtain the speed of an early adult stage C. elegans, where the measured average speed was 0.35 (±0.05) mm/s. The results of this work demonstrate the application of our method to measure the speed of C. elegans undulatory locomotion. This novel approach can be applied to make such measurements without an imaging system, and more importantly, allows directly to detect the locomotion of C. elegans using an electrical signal (i.e., the change in resistance).
Medical ultrasound is a widely used diagnostic imaging modality that provides real-time imaging at a relatively low cost. However, its widespread application is hindered by the need for expert operation, particularly in remote regional areas where trained sonographers are scarce. This paper presents the development of HaptiScan, a state-of-the-art telerobotic ultrasound system equipped with haptic feedback. The system utilizes a commercially available robotic manipulator, the UR5 robot from Universal Robots, integrated with a force/torque sensor and the Phantom Omni haptic device. This configuration enables skilled sonographers to remotely conduct ultrasound procedures via an internet connection, addressing both the geographic and ergonomic limitations faced in traditional sonography. Key innovative features of the system include real-time force feedback, ensuring that sonographers can precisely control the ultrasound probe from a remote location. The system is further enhanced by safety measures such as over-force sensing, patient discomfort monitoring, and emergency stop mechanisms. Quantitative indicators of the system’s performance include successful teleoperation over long distances with time delays, as demonstrated in simulations. These simulations validate the system’s control methodologies, showing stable performance with force feedback under varying time delays and distances. Additionally, the UR5 manipulator’s precision, kinematic, and dynamic models are mathematically formulated to optimize teleoperation. The results highlight the effectiveness of the proposed system in overcoming the technical challenges of remote ultrasound procedures, offering a viable solution for real-world telemedicine applications.
26 June 2020 in IEEE/ASME Transactions on Mechatronics
The development of High-Gravity Centrifuge Systems (HCSs) for G tolerance training has been justified from both a safety and economic perspective. A low-cost HCS can provide a crucial standpoint towards an accessible simulator saving aircrews' lives and air assets during flight operations; however, there are several challenges associated with the design and development of a low-cost HCS. These challenges are a result of the strength and stability of the structure, capability of the main actuator, durability of the sub-floor footing system and cost of Preventive Maintenance (PM). This paper discusses design and development of an efficient and low-cost HCS, named Cyclone. The system has the capability of generating a maximum sustained acceleration of 9G with an onset rate of 5G/sec. Cyclone has a modular design, a capable rotary main drive, and a self-balanced structure with an effective centrifuge radius of 5m. The design and development steps of the system including the mechanical design, motion analysis, and structural analysis are described. These steps have been implemented to meet the highest level of safety for a human-capable system providing an isolated and repeatable motion and force fields for Air Force aircrews and Aviation Medicine specialists to take greater advantage of the system for the purpose of effective centrifuge training and aerospace medicine research. The experimental results of test scenarios are shown. The system has not been human-rated and this step is currently under investigation.
1 May 2014 in Network Modeling Analysis in Health Informatics and Bioinformatics
High-G Centrifuge Systems provide a safe and controllable environment for G motion fields required for fighters’ pilots training. Lacking an operational Human Centrifuge System in Australia, the Institute for Intelligent Systems Research and Innovation (IISRI) at Deakin University has designed and built a low-cost High-G Centrifuge System, named Cyclone. Cyclone has the capability of generating a maximum sustained acceleration of 9G with an onset rate of 5G/sec. The system has an effective arm length of over 5m, which is actuated by a capable gear-motor. This paper addresses the main characteristics of Cyclone including modular design, self-balanced structure and rotating main drive. Moreover, the design and development of the system are discussed and the experimental results of two test scenarios will be presented. The developed system offers the highest level of operational and occupational safety to be rated as a human-capable system. The human-rating of Cyclone is currently investigated.