Pasqualino Sirignano

Prof. Pasqualino Sirignano

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2013 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
Gianmarco de DonatoGianmarco de Donato
Gianmarco de Donato
FSF. Setacci
F. Setacci
Pasqualino SirignanoPasqualino Sirignano
Pasqualino Sirignano
GGG. Galzerano
G. Galzerano
ACA. Cappelli
A. Cappelli
CSC. Setacci
C. Setacci

1 March 2014 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
Gianmarco de DonatoGianmarco de Donato
Gianmarco de Donato
FSFrancesco Setacci
Francesco Setacci
Pasqualino SirignanoPasqualino Sirignano
Pasqualino Sirignano
GGGiuseppe Galzerano
Giuseppe Galzerano
RMRosaria Massaroni
Rosaria Massaroni
CSCarlo Setacci
Carlo Setacci

17 August 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AMAdam Mazurek
Adam Mazurek
KMKrzysztof Piotr Malinowski
Krzysztof Piotr Malinowski
KRKenneth Rosenfield
Kenneth Rosenfield
LCLaura Capoccia
Laura Capoccia
FSFrancesco Speziale
Francesco Speziale
PMPiotr Musiałek
Piotr Musiałek
Background: Single-cohort studies suggest that second-generation stents (SGS; “mesh stents”) may improve carotid artery stenting (CAS) outcomes by limiting peri- and postprocedural cerebral embolism. SGS differ in the stent frame construction, mesh material, and design, as well as in mesh-to-frame position (inside/outside). Objectives: To compare clinical outcomes of SGS in relation to first-generation stents (FGSs; single-layer) in CAS. Methods: We performed a systematic review and meta-analysis of clinical studies with FGSs and SGS (PRISMA methodology, 3302 records). Endpoints were 30-day death, stroke, myocardial infarction (DSM), and 12-month ipsilateral stroke (IS) and restenosis (ISR). A random-effect model was applied. Results: Data of 68,422 patients from 112 eligible studies (68.2% men, 44.9% symptomatic) were meta-analyzed. Thirty-day DSM was 1.30% vs. 4.11% (p < 0.01, data for SGS vs. FGS). Among SGS, both Casper/Roadsaver and CGuard reduced 30-day DSM (by 2.78 and 3.03 absolute percent, p = 0.02 and p < 0.001), whereas the Gore stent was neutral. SGSs significantly improved outcomes compared with closed-cell FGS (30-day stroke 0.6% vs. 2.32%, p = 0.014; DSM 1.3% vs. 3.15%, p < 0.01). At 12 months, in relation to FGS, Casper/Roadsaver reduced IS (−3.25%, p < 0.05) but increased ISR (+3.19%, p = 0.04), CGuard showed a reduction in both IS and ISR (−3.13%, −3.63%; p = 0.01, p < 0.01), whereas the Gore stent was neutral. Conclusions: Pooled SGS use was associated with improved short- and long-term clinical results of CAS. Individual SGS types, however, differed significantly in their outcomes, indicating a lack of a “mesh stent” class effect. Findings from this meta-analysis may provide clinically relevant information in anticipation of large-scale randomized trials.

1 January 2016 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
Gianmarco de DonatoGianmarco de Donato
Gianmarco de Donato
FSFrancesco Setacci
Francesco Setacci
LBLuciano Bresadola
Luciano Bresadola
PCPatrizio Castelli
Patrizio Castelli
RCRoberto Chiesa
Roberto Chiesa
GBGaetano La Barbera
Gaetano La Barbera

1 August 2016 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
AKAndrea KAHLBERG
Andrea KAHLBERG
EREnrico Rinaldi
Enrico Rinaldi
GPGabriele Piffaretti
Gabriele Piffaretti
FSFrancesco Speziale
Francesco Speziale
STSanti Trimarchi
Santi Trimarchi
ASAntonio Sarcina
Antonio Sarcina

1 December 2018 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
ESEugenio Stabile
Eugenio Stabile
GDGianmarco de Donato
Gianmarco de Donato
PMPiotr Musialek
Piotr Musialek
KLKoen De Loose
Koen De Loose
RNRoberto Nerla
Roberto Nerla
GEGiovanni Esposito
Giovanni Esposito