Moonjeong Lee

Ms. Moonjeong Lee


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
HKHyuntae Kim
Hyuntae Kim
JLJungju Lee
Jungju Lee
MYMyungseok Yoon
Myungseok Yoon
MLMoonjeong Lee
Moonjeong Lee
NCNamhun Cho
Namhun Cho
SCSungyun Choi
Sungyun Choi
Recently, the demand for electricity has been increasing worldwide. Thus, more attention has been paid to renewable energy. There are acceptable limits during the integration of renewable energy into distribution systems because there are many effects of integrating renewable energy. Unlike previous studies that have estimated the distributed energy resource (DER) hosting capacity using the standard high voltage and probability approach, in this study, we propose an algorithm to estimate the DER hosting capacity by considering DER outages due to abrupt disturbances or uncertainties based on the generator ramp rate and voltage stability, which involves analysis of the low-voltage aspects. Furthermore, this method does not involve a complicated process or need large amounts of data to estimate the DER hosting capacity because it requires only minimum data for power flow. The proposed algorithm was applied to the IEEE-33 radial distribution system. According to the DER capacity, a voltage stability analysis based on continuation power flow (CPF) was conducted in a case of DER outage to estimate the DER hosting capacity in this case study. Thus, the DER hosting capacity was estimated for the IEEE-33 radial distribution system.

30 June 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
NCNamhun Cho
Namhun Cho
MLMoonjeong Lee
Moonjeong Lee
MYMyungseok Yoon
Myungseok Yoon
SCSungyun Choi
Sungyun Choi
In general, a temporary overvoltage (TOV) on the healthy phases occurs because of the neutral-shift phenomenon during a single line-to-ground (SLG) fault. The TOV can destroy the insulation of electric devices and cause damage to other equipment and customer loads in just a few cycles. In practice, the TOV can be affected by numerous factors: the sequence reactance ratio of the interconnection transformer, the ratio of load to DG, and the distance to the fault. More importantly, inverter-based distributed generations (DGs) have different influences on the TOV from traditional synchronous-machine-based DGs. In this sense, this work performed an efficient and comprehensive investigation on the effect of these various parameter types and their extensive variations, based on steady-state analysis with sequence equivalent circuits and three-dimensional representations. The proposed methodology can facilitate judging the impact of multi-parameter conditions on the TOV readily and comparing the fault characteristics of synchronous-machine-based and inverter-based DGs. Finally, the results can be used for future studies on TOV mitigation techniques.

23 March 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
MLMoonjeong Lee
Moonjeong Lee
MYMyungseok Yoon
Myungseok Yoon
JCJintae Cho
Jintae Cho
SCSungyun Choi
Sungyun Choi
This study proposed a probabilistic methodology based on a confidence interval with the aim of overcoming the limitations of deterministic methods. A stability evaluation technique was required because the output variability of renewable energy can lead to instability of the distribution system. The proposed method can predict the possibility of violating stability in the future. It can also provide a theoretical basis for securing distribution system stability and improving operational efficiency by assessing the in-stability risk and worst-case scenarios. Because of steady-state analysis in the distribution system to which solar power is connected, the probability of violating the standard voltage during the daytime when PV fluctuations are severe was the highest. Moreover, as a result of a simulation of a three-phase short-circuit in the distribution system that is connected to the PV and WT, it was observed that it could violate the allowable capacity of the CB owing to the effects of the power demand pattern and output variability.