20 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SBSergio Mingo Barba
Sergio Mingo Barba
FSFrancesco Schillaci
Francesco Schillaci
RCRoberto Catalano
Roberto Catalano
GPGiada Petringa
Giada Petringa
Daniele MargaroneDaniele Margarone
Daniele Margarone
GCGiuseppe Pablo Cirrone
Giuseppe Pablo Cirrone
ELIMED has been developed and installed at ELI beamlines as a part of the ELIMAIA beamline to transport, monitor, and use laser-driven ion beams suitable for multidisciplinary applications, including biomedical ones. This paper aims to investigate the feasibility to perform radiobiological experiments using laser-accelerated proton beams with intermediate energies (up to 30 MeV). To reach this goal, we simulate a proton source based on experimental data like the ones expected to be available in the first phase of ELIMED commissioning by using the G4-ELIMED application (an application based on the Geant4 toolkit that simulates the full ELIMED beamline). This allows the study of transmission efficiency and the final characteristics of the proton beam at the sample irradiation point. The Energy Selector System is used as an active energy modulator to obtain the desired beam features in a relatively short irradiation time (around 6 min). Furthermore, we demonstrate the capability of the beamline to filter out other ion contaminants, typically co-accelerated in a laser-plasma environment. These results can be considered as a detailed feasibility study for the use of ELIMED for various user applications such as radiobiological experiments with ultrahigh dose rate proton beams.

19 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MMMauro Mauro Menichelli
Mauro Mauro Menichelli
SASaba Aziz
Saba Aziz
ABAishah Bashiri
Aishah Bashiri
MBMarco Bizzarri
Marco Bizzarri
CBClarissa Buti
Clarissa Buti
Nicola ZemaNicola Zema
Nicola Zema
Hydrogenated amorphous silicon (a-Si:H) devices on flexible substrates are currently being studied for application in dosimetry and beam flux measurements. The necessity of in vivo dosimetry requires thin devices with maximal transparency and flexibility. For this reason, a thin (<10 µm) a-Si:H device deposited on a thin polyimide sheet is a very valid option for this application. Furthermore, a-Si:H is a material that has an intrinsically high radiation hardness. In order to develop these devices, the HASPIDE (Hydrogenated Amorphous Silicon Pixel Detectors) collaboration has implemented two different device configurations: n-i-p type diodes and charge-selective contact devices.Charge-selective contact-based devices have been studied for solar cell applications and, recently, the above-mentioned collaboration has tested these devices for X-ray dose measurements. In this paper, the HASPIDE collaboration has studied the X-ray and proton response of charge-selective contact devices deposited on Polyimide. The linearity of the photocurrent response to X-ray versus dose-rate has been assessed at various bias voltages. The sensitivity to protons has also been studied at various bias voltages and the wide range linearity has been tested for fluxes in the range from 8.3 × 107 to 2.49 × 1010 p/(cm2 s).

18 March 2026 in Sensors
Verified
Journal Article
Open access
PDF file
GPGiada Petringa
Giada Petringa
LRLuigi Angelo Raffaele
Luigi Angelo Raffaele
GCGiacomo Cuttone
Giacomo Cuttone
MGMariacristina Guarrera
Mariacristina Guarrera
AKAlma Kurmanova
Alma Kurmanova
GCGiuseppe Pablo Cirrone
Giuseppe Pablo Cirrone
Percentage depth–dose (PDD) distributions are fundamental to characterizing radiation beams in radiotherapy. This review provides an overview of both methods and sensor technologies for measuring PDD in photon, electron, proton, and carbon-ion beams. We summarize conventional dosimetry techniques, including water-phantom scanning with ionization chambers (cylindrical and parallel-plate) and radiochromic film, and discuss their strengths (established accuracy, calibration traceability) and limitations (volume averaging, delayed readout). We then examine emerging sensor technologies designed to improve spatial resolution, speed, and radiation hardness: multi-layer ionization chambers and Faraday cups for one-shot PDD acquisition; scintillator-based detectors (liquid, plastic, and fiber-optic) enabling real-time and high-resolution depth–dose measurements; advanced semiconductor detectors including silicon carbide diodes; as well as novel approaches such as ionoacoustic range sensing for proton beams. For each modality and detector type, we emphasize clinical relevance, measurement accuracy, spatial resolution, radiation durability, and suitability for high dose-per-pulse environments (e.g., FLASH radiotherapy). Current challenges, such as detector response in regions of steep dose gradient, saturation or recombination at ultra-high dose rates, and energy-dependent sensitivity in mixed radiation fields, are analyzed in detail. We also highlight the limitations of each technique and discuss ongoing improvements and prospects for clinical implementation. In summary, no single detector technology fully satisfies all requirements for fast, high-accuracy, high-resolution, radiation-hard PDD measurement, but the integration of emerging sensor innovations into clinical dosimetry promises to enhance the precision and efficiency of radiotherapy quality assurance.