This review discusses the critical issues and recommended practices from the perspective of myoelectric interfaces. The major benefits and challenges of myoelectric interfaces are evaluated. The article aims to fill gaps left by previous reviews and identify avenues for future research. Recommendations are given, for example, for electrode placement, sampling rate, segmentation, and classifiers. Four groups of applications where myoelectric interfaces have been adopted are identified: assistive technology, rehabilitation technology, input devices, and silent speech interfaces. The state-of-the-art applications in each of these groups are presented.Peer reviewe
Corticokinematic coherence (CKC) reflects coupling between magnetoencephalographic (MEG) signals and hand kinematics, mainly occurring at hand movement frequency (F0) and its first harmonic (F1). Since CKC can be obtained for both active and passive movements, it has been suggested to mainly reflect proprioceptive feedback to the primary sensorimotor (SM1) cortex. However, the directionality of the brain-kinematics coupling has not been previously assessed and was thus quantified in the present study by means of renormalized partial directed coherence (rPDC). MEG data were obtained from 15 subjects who performed right index-finger movements and whose finger was, in another session, passively moved, with or without tactile input. Four additional subjects underwent the same task with slowly varying movement pace, spanning the 1-5 Hz frequency range. The coupling between SM1 activity recorded with MEG and finger kinematics was assessed with coherence and rPDC. In all conditions, the afferent rPDC spectrum, which resembled the coherence spectrum, displayed higher values than the efferent rPDC spectrum. The afferent rPDC was 37% higher when tactile input was present, and it was at highest at F1 of the passive conditions; the efferent rPDC level did not differ between conditions. The apparent latency for the afferent input, estimated within the framework of the rPDC analysis, was 50-100 ms. The higher directional coupling between hand kinematics and SM1 activity in afferent than efferent direction strongly supports the view that CKC mainly reflects movement-related somatosensory proprioceptive afferent input to the contralateral SM1 cortex.
Corticokinematic coherence (CKC) refers to coupling between magnetoencephalographic (MEG) brain activity and hand kinematics. For voluntary hand movements, CKC originates mainly from the primary sensorimotor (SM1) cortex. To learn about the relative motor and sensory contributions to CKC, we recorded CKC from 15 healthy subjects during active and passive right index-finger movements. The fingertip was either touching or not touching table, resulting in active-touch, active-no-touch, passive-touch, and passive-no-touch conditions. The kinematics of the index-finger was measured with a 3-axis accelerometer. Beamformer analysis was used to locate brain activations for the movements; somatosensory-evoked fields (SEFs) elicited by pneumatic tactile stimulation of the index finger served as a functional landmark for cutaneous input. All active and passive movements resulted in statistically significant CKC at the movement frequency (F0) and its first harmonic (F1). The main CKC sources at F0 and F1 were in the contralateral SM1 cortex with no spatial differences between conditions, and distinct from the SEF sources. At F1, the coherence was by two thirds stronger for passive than active movements, with no difference between touch vs. no-touch conditions. Our results suggest that the CKC occurring during repetitive finger movements is mainly driven by somatosensory, primarily proprioceptive, afferent input to the SM1 cortex, with negligible effect of cutaneous input.
Magnetoencephalographic (MEG) signals recorded from the primary sensorimotor (SM1) cortex are coherent with kinematics of both active and passive finger movements. The coherence mainly reflects movement-related proprioceptive afference to the cortex. Here we describe a novel MEG-compatible stimulator to generate computer-controlled passive finger and toe movements that can be used as stimuli in functional brain-imaging experiments. The movements are produced by pneumatic artificial muscle (PAM), elastic actuator that shortens with increasing air pressure. To test the applicability of the stimulator to functional brain-imaging, 4-min trains of passive repetitive 5-mm flexion-extension movements of the right and left index finger and the right hallux were produced at 3Hz while the subject's brain activity was measured with whole-scalp MEG and finger or toe kinematics with an accelerometer. In all ten subjects studied, statistically significant coherence (up to 0.78) occurred between the accelerometer and MEG signals at the movement frequency or its first harmonic. Sources of coherent activity were in the contralateral hand or foot SM1 cortices. Movement-evoked fields elicited with intermittent movements of the right index finger (once every 3.2-4.0s; mean±SD peak response latency 88±25ms) were co-located with the respective coherent sources. We further moved the right index finger at 3, 6, and 12Hz (movement ranges 5, 3, and 2mm, respectively), and analyzed the first 1, 2, and 4-min epochs of data. One minute of data was sufficient to locate the left hand area of the SM1 cortex at all movement frequencies. Sound-induced spurious coherence was reliably ruled out in a control experiment. Our novel movement stimulator thus provides a robust and reliable tool to track proprioceptive afference to the cortex and to locate the SM1 cortex.
Proprioceptive perception is impaired with aging, but little is known about aging-related deterioration of proprioception at the cortical level. Corticokinematic coherence (CKC) between limb kinematic and magnetoencephalographic (MEG) signals reflects cortical processing of proprioceptive afference. We, thus, compared CKC strength to ankle movements between younger and older subjects, and examined whether CKC predicts postural stability. Fifteen younger (range 18–31 years) and eight older (66–73 years) sedentary volunteers were seated in MEG, while their right and left ankle joints were moved separately at 2 Hz (for 4 min each) using a novel MEG-compatible ankle-movement actuator. Coherence was computed between foot acceleration and MEG signals. CKC strength at the movement frequency (F0) and its first harmonic (F1) was quantified. In addition, postural sway was quantified during standing eyes-open and eyes-closed tasks to estimate motor performance. CKC peaked in the gradiometers over the vertex, and was significantly stronger (~76%) at F0 for the older than younger subjects. At F1, only the dominant-leg CKC was significantly stronger (~15%) for the older than younger subjects. In addition, CKC (at F1) was significantly stronger in the non-dominant than dominant leg, but only in the younger subjects. Postural sway was significantly (~64%) higher in the older than younger subjects when standing with eyes closed. Regression models indicated that CKC strength at F1 in the dominant leg and age were the only significant predictors for postural sway. Our results indicated that aging-related cortical-proprioceptive processing is altered by aging. Stronger CKC may reflect poorer cortical proprioceptive processing, and not solely the amount of proprioceptive afference as suggested earlier. In combination with ankle-movement actuator, CKC can be efficiently used to unravel proprioception-related-neuronal mechanisms and the related plastic changes in aging, rehabilitation, motor-skill acquisition, motor disorders etc.
Hand velocity and acceleration are coherent with magnetoencephalographic (MEG) signals recorded from the contralateral primary sensorimotor (SM1) cortex. To learn more of this interaction, we compared the coupling of MEG signals with four hand-action-related peripheral signals: acceleration, pressure, force, and electromyogram (EMG). Fifteen subjects performed self-paced repetitive hand-action tasks for 3.5min at a rate of about 3Hz. Either acceleration, pressure or force signal was acquired with MEG and EMG signals during (1) flexions-extensions of right-hand fingers, with thumb touching the other fingers (acceleration; free), (2) dynamic index-thumb pinches against an elastic rubber ball attached to a pressure sensor (pressure and acceleration; squeeze), and (3) brief fixed-finger-position index-thumb pinches against a rigid load cell (force; fixed-pinch). Significant coherence occurred between MEG and all the four peripheral measures at the fundamental frequency of the hand action (F0) and its first harmonic (F1). In all tasks, the cortical sources contributing to the cross-correlograms were located at the contralateral hand SM1 cortex, with average inter-source distance (mean±SEM) of 9.5±0.3mm. The coherence was stronger with respect to pressure (0.40±0.03 in squeeze) and force (0.38±0.04 in fixed-pinch) than acceleration (0.24±0.03 in free) and EMG (0.25±0.02 in free, and 0.29±0.04 in fixed-pinch). The results imply that the SM1 cortex is strongly coherent at F0 and F1 with hand-action-related pressure and force, in addition to the previously demonstrated EMG, velocity, and acceleration. All these measures, especially force and pressure, are potential tools for functional mapping of the SM1 cortex.