The implementation and validation of anti-SARS-CoV-2 IgG serological assays are reported in this paper. S1 and RBD proteins were used to coat ELISA plates, and several secondary antibodies served as reporters. The assays were initially validated with 50 RT-PCR positive COVID-19 sera, which showed high IgG titers of mainly IgG1 isotype, followed by IgG3. Low or no IgG2 and IgG4 titers were detected. Then, the RBD/IgG assay was further validated with 887 serum samples from RT-PCR positive COVID-19 individuals collected at different times, including 7, 14, 21, and 40 days after the onset of symptoms. Most of the sera were IgG positive at day 40, with seroconversion happening after 14–21 days. A third party conducted an additional performance test of the RBD/IgG assay with 406 sera, including 149 RT-PCR positive COVID-19 samples, 229 RT-PCR negative COVID-19 individuals, and 28 sera from individuals with other viral infections not related to SARS-CoV-2. The sensitivity of the assay was 99.33%, with a specificity of 97.82%. All the sera collected from individuals with infectious diseases other than COVID-19 were negative. Given the robustness of this RBD/IgG assay, it received approval from the sanitary authority in Mexico (COFEPRIS) for production and commercialization under the name UDISTEST-V2G®.
1 June 2018 in Journal of Pharmaceutical and Biomedical Analysis
Physicochemical and structural properties of proteins used as active pharmaceutical ingredients of biopharmaceuticals are determinant to carry out their biological activity. In this regard, the assays intended to evaluate functionality of biopharmaceuticals provide confirmatory evidence that they contain the appropriate physicochemical properties and structural conformation. The validation of the methodologies used for the assessment of critical quality attributes of biopharmaceuticals is a key requirement for manufacturing under GMP environments. Herein we present the development and validation of a flow cytometry-based methodology for the evaluation of adalimumab's affinity towards membrane-bound TNFα (mTNFα) on recombinant CHO cells. This in vitro methodology measures the interaction between an in-solution antibody and its target molecule onto the cell surface through a fluorescent signal. The characteristics evaluated during the validation exercise showed that this methodology is suitable for its intended purpose. The assay demonstrated to be accurate (r2 = 0.92, slope = 1.20), precise (%CV ≤ 18.31) and specific (curve fitting, r2 = 0.986-0.997) to evaluate binding of adalimumab to mTNFα. The results obtained here provide evidence that detection by flow cytometry is a viable alternative for bioassays used in the pharmaceutical industry. In addition, this methodology could be standardized for the evaluation of other biomolecules acting through the same mechanism of action.
7 November 2014 in Clinical and Experimental Immunology
Technological advances allowed the development of high-throughput instruments such as IntelliCyt iQue Screener PLUS®. Here, we took advantage of this technology to transfer a previously validated cytotoxicity assay. The evaluated parameters were cell permeability, caspase activation and phosphatidyl serine exposure. The assay was accurate (r2 = 0.90), precise (%CV ≤ 18.90) and specific. These results showed that this technology is suitable to be used in control quality environments. In addition, the automation provided a faster acquisition and analysis of data with precise and accurate results. This application could be implemented to evaluate another in vitro mechanism of action of different biotherapeutics.