Christoph Triska

Dr. Christoph Triska

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Journal of Strength & Conditioning Research
Verified
Journal Article
Closed access
DPDaniel Muniz Pumares
Daniel Muniz Pumares
BKBettina Karsten
Bettina Karsten
CTChristoph Triska
Christoph Triska
MGMark Glaister
Mark Glaister
Muniz-Pumares, D, Karsten, B, Triska, C, and Glaister, M. Methodological approaches and related challenges associated with the determination of critical power and W′. J Strength Cond Res 33(2): 584–596, 2019—The relationship between exercise intensity and time to task failure (P-T relationship) is hyperbolic, and characterized by its asymptote (critical power [CP]) and curvature constant (W′). The determination of these parameters is of interest for researchers and practitioners, but the testing protocol for CP and W′ determination has not yet been standardized. Conventionally, a series of constant work rate (CWR) tests to task failure have been used to construct the P-T relationship. However, the duration, number, and recovery between predictive CWR and the mathematical model (hyperbolic or derived linear models) are known to affect CP and W′. Moreover, repeating CWR may be deemed as a cumbersome and impractical protocol. Recently, CP and W′ have been determined in field and laboratory settings using time trials, but the validity of these methods has raised concerns. Alternatively, a 3-minute all-out test (3MT) has been suggested, as it provides a simpler method for the determination of CP and W′, whereby power output at the end of the test represents CP, and the amount of work performed above this end-test power equates to W′. However, the 3MT still requires an initial incremental test and may overestimate CP. The aim of this review is, therefore, to appraise current methods to estimate CP and W′, providing guidelines and suggestions for future research where appropriate.

1 March 2017 in Journal of Strength & Conditioning Research
Verified
Journal Article
Closed access
ANAlfred Nimmerichter
Alfred Nimmerichter
NNNina Novak
Nina Novak
CTChristoph Triska
Christoph Triska
BPBernhard Prinz
Bernhard Prinz
BBBrynmor C. Breese
Brynmor C. Breese
Nimmerichter, A, Novak, N, Triska, C, Prinz, B, and Breese, BC. Validity of treadmill-derived critical speed on predicting 5,000-meter track-running performance. J Strength Cond Res 31(3): 706–714, 2017—To evaluate 3 models of critical speed (CS) for the prediction of 5,000-m running performance, 16 trained athletes completed an incremental test on a treadmill to determine maximal aerobic speed (MAS) and 3 randomly ordered runs to exhaustion at the ∆70% intensity, at 110% and 98% of MAS. Critical speed and the distance covered above CS (D′) were calculated using the hyperbolic speed-time (HYP), the linear distance-time (LIN), and the linear speed inverse-time model (INV). Five thousand meter performance was determined on a 400-m running track. Individual predictions of 5,000-m running time (t = [5,000−D′]/CS) and speed (s = D’/t + CS) were calculated across the 3 models in addition to multiple regression analyses. Prediction accuracy was assessed with the standard error of estimate (SEE) from linear regression analysis and the mean difference expressed in units of measurement and coefficient of variation (%). Five thousand meter running performance (speed: 4.29 ± 0.39 m·s−1; time: 1,176 ± 117 seconds) was significantly better than the predictions from all 3 models (p < 0.0001). The mean difference was 65–105 seconds (5.7–9.4%) for time and −0.22 to −0.34 m·s−1 (−5.0 to −7.5%) for speed. Predictions from multiple regression analyses with CS and D′ as predictor variables were not significantly different from actual running performance (−1.0 to 1.1%). The SEE across all models and predictions was approximately 65 seconds or 0.20 m·s−1 and is therefore considered as moderate. The results of this study have shown the importance of aerobic and anaerobic energy system contribution to predict 5,000-m running performance. Using estimates of CS and D′ is valuable for predicting performance over race distances of 5,000 m.

3 April 2018 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
RKRadka Klepochová
Radka Klepochová
LVLadislav Valkovič
Ladislav Valkovič
THThomas Hochwartner
Thomas Hochwartner
CTChristoph Triska
Christoph Triska
NBNorbert Bachl
Norbert Bachl
Martin KrssakMartin Krssak
Martin Krssak
Purpose: The influence of endurance training on skeletal muscle metabolism can currently be studied only by invasive sampling or through a few related parameters that are investigated by either proton (1H) or phosphorus (31P) magnetic resonance spectroscopy (MRS). The aim of this study was to compare the metabolic differences between endurance-trained triathletes and healthy volunteers using multi-parametric data acquired by both, 31P- and 1H-MRS, at ultra-high field (7T) in a single experimental protocol. This study also aimed to determine the interrelations between these MRS-derived metabolic parameters. Methods: Thirteen male triathletes and ten active male volunteers participated in the study. Proton MRS data from the vastus lateralis yielded concentrations of acetylcarnitine, carnosine, and intramyocellular lipids (IMCL). For the measurement of phosphodiesters (PDEs), inorganic phosphate (Pi), phosphocreatine (PCr), and maximal oxidative capacity (Qmax) phosphorus MRS data were acquired at rest, during 6 min of submaximal exercise and following immediate recovery. Results: The triathletes exhibited significantly higher IMCL levels, higher initial rate of PCr resynthesis (VPCr) during the recovery period, a shorter PCr recovery time constant (τPCr), and higher Qmax. Multivariate stepwise regression analysis identified PDE as the strongest independent predictor of whole-body maximal oxygen uptake (VO2max). Conclusion: In conclusion, we cannot suggest a single MRS-based parameter as an exclusive biomarker of muscular fitness and training status. There is, rather, a combination of different parameters, assessable during a single multi-nuclear MRS session that could be useful for further cross-sectional and/or focused interventional studies on skeletal muscle fitness and training effects.

10 August 2015 in International Journal of Sports Medicine
Verified
Journal Article
Closed access
PDF file
CTChristoph Triska
Christoph Triska
HTH. Tschan
H. Tschan
GTG. Tazreiter
G. Tazreiter
ANAlfred Nimmerichter
Alfred Nimmerichter
To compare critical power (CP) and the maximum work performed above CP (W′) obtained from a single-visit laboratory test with a single-visit field test, 10 trained cyclists (V˙O2max 63.2±5.5 mL·min−1·kg−1) performed a laboratory and a field test. The laboratory test consisted of 3 trials to exhaustion between 2–15 min and the field test comprised 3 maximal efforts of 2, 6 and 12 min, where power output was measured using a mobile power meter. CP and W′ were estimated using 3 mathematical models (hyperbolic, linear work-time, linear power −1/time). The agreement between laboratory and field conditions was assessed with the 95% limits of agreement (LoA). CP was not significantly different between laboratory (280±33 W) and field conditions (281±28 W) (P=0.950). W′ was significantly higher in laboratory (21.6±7.1 kJ) compared to field conditions (16.3±7.4 kJ) (P=0.013). The bias was −2.8±27 W (95% LoA: −55 to 50 W) and 6.4±5.1 kJ (95% LoA: −3.5 to 16.4 kJ) for CP and W′, respectively. No differences between the mathematical models were found for CP and W′ (P=0.054–1.000). Although CP was not significantly different between conditions, a high random variation does not support its interchangeable use. The mathematical model used has no influence on estimates of CP and W′.

1 July 2021 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
ARAstrid Reif
Astrid Reif
BWBarbara Wessner
Barbara Wessner
PHPatricia Haider
Patricia Haider
HTHarald Tschan
Harald Tschan
CTChristoph Triska
Christoph Triska
Oral contraceptive pills (OCP) are very popular in female athletes not only for contraceptive effects but also due to the possibility of cycle manipulation. Moreover, it is debatable whether the manipulation of the menstrual cycle has a beneficial effect on exercise performance. Therefore, the aim of this study was to investigate potential differences in knee-extensor and flexor strength performance of first division team sport athletes between phases of the oral contraceptive cycle. Sixteen female handball players (age: 23.3 ± 3.1 years; body mass: 67.0 ± 8.52 kg; body stature: 1.68 ± 0.05 m) using a monophasic OCP participated in strength performance tests, once during OCP consumption (CONS) and once during withdrawal (WITH). Tests were performed on a dynamometer to measure knee-extensor and flexor maximal voluntary isokinetic and isometric torque. Prior to each test, body mass was assessed, and venous blood samples were collected. Wilcoxon signed-rank test and magnitude-based inferences have been conducted to analyze differences between WITH and CONS. Significance was accepted at P < 0.05. No significant differences between oral contraceptive cycle phases of knee-extensor and flexor strength parameters and body mass have been indicated (all at P > 0.05). Follicle-stimulating hormone (FSH) (P = 0.001) and luteinizing hormone (P = 0.013) were significantly higher in WITH, whereby estradiol and progesterone showed no significant difference between phases (both at P > 0.05). These results support the notion that knee-extensor and flexor isokinetic and isometric strength performance does not differ between phases of oral contraceptive cycle in well-trained team sport athletes. OCP intake is suggested to cause a stable but downregulated hormone cycle, which has no effect on knee-extensor and flexor strength when comparing oral contraceptive cycle phases. Therefore, manipulation of the female cycle using OCP in order to achieve a higher knee-extensor and flexor strength performance does not seem to be justified; however, it is currently unclear if cycle manipulation might affect other physiological systems.

15 January 2018 in European Journal of Sport Science
Verified
Journal Article
Open access
CTChristoph Triska
Christoph Triska
BKBettina Karsten
Bettina Karsten
CBChris Beedie
Chris Beedie
BKBernhard Koller‐Zeisler
Bernhard Koller‐Zeisler
ANAlfred Nimmerichter
Alfred Nimmerichter
HTHarald Tschan
Harald Tschan
The aim of the study was to determine whether estimates of the speed-duration relationship are affected using different time-trial (TT) field-based testing protocols, where exhaustive times were located within the generally recommended durations of 2-15min. Ten triathletes (mean +/- SD age: 31.0 +/- 5.7years; height: 1.81 +/- 0.05m; body mass: 76.5 +/- 6.8kg) performed two randomly assigned field tests to determine critical speed (CS) and the total distance covered above CS (D'). CS and D' were obtained using two different protocols comprising three TT that were interspersed by 60min passive rest. The TTs were 12, 7, and 3min in Protocol I and 10, 5, and 2min in Protocol II. A linear relationship of speed vs. the inverse of time (s=D'x1/t+CS) was used to determine parameter estimates. Significant differences were found for CS (p=0.026), but not for D' (p=0.123). The effect size for CS (d=0.305) was considered small, while that for D' was considered moderate (d=0.742). CS was significantly correlated between protocols (r=0.934; p<0.001), however, no correlation was found for D' (r=0.053; p=0.884). The 95% limits of agreement were +/- 0.28ms(-1) and +/- 73.9m for CS and D', respectively. These findings demonstrate that the choice of exhaustive times within commonly accepted durations results in different estimates of CS and D', and thus protocols cannot be used interchangeably. The use of a consistent protocol is therefore recommended, when investigating or monitoring the speed-duration relationship estimates in well-trained athletes.