A Bayesian method is described for reconstruction of high-resolution 3D images from the microPET small-animal scanner. Resolution recovery is achieved by explicitly modelling the depth dependent geometric sensitivity for each voxel in combination with an accurate detector response model that includes factors due to photon pair non-collinearity and inter-crystal scatter and penetration. To reduce storage and computational costs we use a factored matrix in which the detector response is modelled using a sinogram blurring kernel. Maximum a posteriori (MAP) images are reconstructed using this model in combination with a Poisson likelihood function and a Gibbs prior on the image. Reconstructions obtained from point source data using the accurate system model demonstrate a potential for near-isotropic FWHM resolution of approximately 1.2 mm at the center of the field of view compared with approximately 2 mm when using an analytic 3D reprojection (3DRP) method with a ramp filter. These results also show the ability of the accurate system model to compensate for resolution loss due to crystal penetration producing nearly constant radial FWHM resolution of 1 mm out to a 4 mm radius. Studies with a point source in a uniform cylinder indicate that as the resolution of the image is reduced to control noise propagation the resolution obtained using the accurate system model is superior to that obtained using 3DRP at matched background noise levels. Additional studies using pie phantoms with hot and cold cylinders of diameter 1-2.5 mm and 18FDG animal studies appear to confirm this observation.
In emission tomography statistically based iterative methods can improve image quality relative to analytic image reconstruction through more accurate physical and statistical modelling of high-energy photon production and detection processes. Continued exponential improvements in computing power, coupled with the development of fast algorithms, have made routine use of iterative techniques practical, resulting in their increasing popularity in both clinical and research environments. Here we review recent progress in developing statistically based iterative techniques for emission computed tomography. We describe the different formulations of the emission image reconstruction problem and their properties. We then describe the numerical algorithms that are used for optimizing these functions and illustrate their behaviour using small scale simulations.
19 December 2018 in IEEE Transactions on Medical Imaging
Recently, deep neural networks have been widely and successfully applied in computer vision tasks and have attracted growing interest in medical imaging. One barrier for the application of deep neural networks to medical imaging is the need for large amounts of prior training pairs, which is not always feasible in clinical practice. This is especially true for medical image reconstruction problems, where raw data are needed. Inspired by the deep image prior framework, in this paper, we proposed a personalized network training method where no prior training pairs are needed, but only the patient’s own prior information. The network is updated during the iterative reconstruction process using the patient-specific prior information and measured data. We formulated the maximum-likelihood estimation as a constrained optimization problem and solved it using the alternating direction method of multipliers algorithm. Magnetic resonance imaging guided positron emission tomography reconstruction was employed as an example to demonstrate the effectiveness of the proposed framework. Quantification results based on simulation and real data show that the proposed reconstruction framework can outperform Gaussian post-smoothing and anatomically guided reconstructions using the kernel method or the neural-network penalty.
In this paper, the authors review the field of resolution modeling in positron emission tomography (PET) image reconstruction, also referred to as point‐spread‐function modeling. The review includes theoretical analysis of the resolution modeling framework as well as an overview of various approaches in the literature. It also discusses potential advantages gained via this approach, as discussed with reference to various metrics and tasks, including lesion detection observer studies. Furthermore, attention is paid to issues arising from this approach including the pervasive problem of edge artifacts, as well as explanation and potential remedies for this phenomenon. Furthermore, the authors emphasize limitations encountered in the context of quantitative PET imaging, wherein increased intervoxel correlations due to resolution modeling can lead to significant loss of precision (reproducibility) for small regions of interest, which can be a considerable pitfall depending on the task of interest.
24 September 2018 in IEEE Transactions on Medical Imaging
PET image reconstruction is challenging due to the ill-poseness of the inverse problem and limited number of detected photons. Recently deep neural networks have been widely and successfully used in computer vision tasks and attracted growing interests in medical imaging. In this work, we trained a deep residual convolutional neural network to improve PET image quality by using the existing inter-patient information. An innovative feature of the proposed method is that we embed the neural network in the iterative reconstruction framework for image representation, rather than using it as a post-processing tool. We formulate the objective function as a constrained optimization problem and solve it using the alternating direction method of multipliers (ADMM) algorithm. Both simulation data and hybrid real data are used to evaluate the proposed method. Quantification results show that our proposed iterative neural network method can outperform the neural network denoising and conventional penalized maximum likelihood methods.
30 July 2014 in IEEE Transactions on Medical Imaging
Image reconstruction from low-count positron emission tomography (PET) projection data is challenging because the inverse problem is ill-posed. Prior information can be used to improve image quality. Inspired by the kernel methods in machine learning, this paper proposes a kernel based method that models PET image intensity in each pixel as a function of a set of features obtained from prior information. The kernel-based image model is incorporated into the forward model of PET projection data and the coefficients can be readily estimated by the maximum likelihood (ML) or penalized likelihood image reconstruction. A kernelized expectation-maximization algorithm is presented to obtain the ML estimate. Computer simulations show that the proposed approach can achieve better bias versus variance trade-off and higher contrast recovery for dynamic PET image reconstruction than the conventional maximum likelihood method with and without post-reconstruction denoising. Compared with other regularization-based methods, the kernel method is easier to implement and provides better image quality for low-count data. Application of the proposed kernel method to a 4-D dynamic PET patient dataset showed promising results.