Effective separation methods for fractionating blood components are needed for numerous diagnostic and research applications. This paper presents the use of acoustophoresis, an ultrasound based microfluidic separation technology, for label-free, gentle and continuous separation of mononuclear cells (MNCs) from diluted whole blood. Red blood cells (RBCs) and MNCs behave similar in an acoustic standing wave field, compromising acoustic separation of MNC from RBC in standard buffer systems. However, by optimizing the buffer conditions and thereby changing the acoustophoretic mobility of the cells, we were able to enrich MNCs relative to RBCs by a factor of 2,800 with MNC recoveries up to 88%. The acoustophoretic microchip can perform cell separation at a processing rate of more than 1 × 105 cells/s, corresponding to 5 µl/min undiluted whole blood equivalent. Thus, acoustophoresis can be easily integrated with further down-stream applications such as flow cytometry, making it a superior alternative to existing MNC isolation techniques.
Multiplex separation of mixed cell samples is required in a variety of clinical and research applications. Herein, we present an acoustic microchip with multiple outlets and integrated pre-alignment channel to enable high performance and label-free separation of three different cell or particle fractions simultaneously at high sample throughput. By implementing a new cooling system for rigorous temperature control and minimal acoustic energy losses, we were able to operate the system isothermally and sort suspensions of 3, 5 and 7 μm beads with high efficiencies (>95.4%) and purities (>96.3%) at flow rates up to 500 μL min−1 corresponding to a throughput of ∼2.5 × 106 beads per min. Also, human viable white blood cells were successfully fractionated into lymphocytes, monocytes and granulocytes with high purities of 96.5 ± 1.6%, 71.8 ± 10.1% and 98.8 ± 0.5%, respectively, as well as high efficiencies (96.8 ± 3.3%, 66.7 ± 3.2% and 99.0 ± 0.7%) at flow rates up to 100 μL min−1 (∼100 000 cells per min). By increasing the flow rate up to 300 μL min−1 (∼300 000 cells per min) both lymphocytes and granulocytes were still recovered with high purities (92.8 ± 1.9%, 98.2 ± 1 .0%), whereas the monocyte purity decreased to 20.9 ± 10.3%. The proposed isothermal multiplex acoustophoresis platform offers efficient fractionation of complex samples in a label-free and continuous manner at thus far unreached high sample throughput rates.
Acoustophoresis is a technique that applies ultrasonic standing wave forces in a microchannel to sort cells depending on their physical properties in relation to the surrounding media. Cell handling and separation for research and clinical applications aims to efficiently separate specific cell populations. Here, we investigated the sorting of CD8 lymphocytes from peripheral blood progenitor cell (PBPC) products by affinity-bead-mediated acoustophoresis. PBPC samples were obtained from healthy donors (n = 4) and patients (n = 18). Mononuclear cells were labeled with anti-CD8-coated magnetic beads and sorted on an acoustophoretic microfluidic device and by standard magnetic cell sorting as a reference method. CD8 lymphocytes were acoustically sorted with a mean purity of 91% ± 8% and a median separation efficiency of 63% (range 15.1%–90.5%) as compared to magnetic sorting (purity 91% ± 14%, recovery 29% (range 5.1%–47.3%)). The viability as well as the proliferation capacity of sorted lymphocytes in the target fraction were unimpaired and, furthermore, hematopoietic progenitor cell assay revealed a preserved clonogenic capacity post-sorting. Bead-mediated acoustophoresis can, therefore, be utilized to efficiently sort less frequent CD8+ lymphocytes from PBPC products in a continuous flow mode while maintaining cell viability and functional capacity of both target and non-target fractions.
We present a new experimental method that measures the compressibility of phenotype-specific cell populations. This is done by performing statistical analysis of the cell counts from the outlets of an acoustophoresis chip as a function of the increasing actuator voltage (i.e. acoustic energy density) during acoustophoretic separation. The theoretical separation performance curve, henceforth, Side-Stream Recovery ( $$\mathrm {SSR}$$ ), vs the piezo-actuator voltage (V) is derived by moment analysis of a one-dimensional model of acoustophoresis separation, accounting for distributions of the cell or microparticle properties and the system parameters (hydrodynamics, radiation force, drag enhancement, and acoustic streaming). The acoustophoretic device is calibrated with polymer microbeads of known properties by fitting the experimental $$\mathrm {SSR}$$ with the theoretical $$\mathrm {SSR}$$ , in which the acoustic energy density is considered proportional to the squared voltage, i.e. $$E_\mathrm {ac}^{}=\alpha \,V^2_{}$$ . The fitting parameter $$\alpha$$ for the calibration procedure is the device effectivity, reflecting the efficiency in performing acoustophoretic microparticle displacement. Once calibrated, the compressibility of unknown cells is estimated by fitting experimental $$\mathrm {SSR}$$ cell data points with the theoretical $$\mathrm {SSR}$$ curve. In this procedure, the microparticle compressibility is the fitting parameter. The method is applied to estimate the compressibility of a variety of cell populations showing its utility in terms of rapid analysis and need for minute sample amounts.