Natalia Vázquez

Dr. Natalia Vázquez

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2017 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
NVNatalia Vázquez
Natalia Vázquez
CRCarlos A. Rodríguez-Barrientos
Carlos A. Rodríguez-Barrientos
SASalvador D. Aznar-Cervantes
Salvador D. Aznar-Cervantes
MCManuel Chacón
Manuel Chacón
JCJosé L. Cenis
José L. Cenis
JMJesús Merayo-Lloves
Jesús Merayo-Lloves
Purpose: Develop a silk fibroin (SF)-based artificial endothelial graft for its use in a rabbit Descemet membrane endothelial keratoplasty (DMEK). Methods: Human and rabbit artificial corneal endothelial grafts were developed through the culture of human and rabbit corneal endothelial cells (CECs) on SF films. Rabbit artificial SF endothelial grafts were transplanted in a DMEK surgery into a rabbit in vivo model. Results: SF artificial endothelial grafts showed the characteristic endothelial markers: zonula occludens (ZO-1) and Na+/K+ ATPase. In a rabbit model of DMEK surgery, SF artificial endothelial graft restored the corneal transparency and thickness at 6 week of follow-up. Anterior segment optical coherence tomography revealed the SF graft as a fully integrated component in the corneal tissue, displaying a similar corneal thickness and endothelial cell count when compared with its healthy contralateral cornea. Histologic analysis showed that the SF artificial endothelial graft was attached and integrated on the surface of the corneal stroma without a significant inflammatory reaction, and rabbit CECs consisted in a monolayer that showed their characteristic markers ZO-1 and Na+/K+ ATPase, suggesting proper intercellular junctions and cellular pump function. Conclusions: We have developed SF films with biological properties that supported the growth of rabbit and human CECs, which showed normal morphology and characteristic markers; and with mechanical properties that allowed its use in a DMEK surgery, proving its in vivo functionality in a rabbit model of endothelial dysfunction.

1 December 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
NVNatalia Vázquez
Natalia Vázquez
MCManuel Chacón
Manuel Chacón
CRCarlos A Rodríguez-Barrientos
Carlos A Rodríguez-Barrientos
JMJesús Merayo-Lloves
Jesús Merayo-Lloves
MNMiguel Naveiras
Miguel Naveiras
ÁMÁlvaro Meana
Álvaro Meana
Corneal keratoplasty (penetrating or lamellar) using cadaveric human tissue, is nowadays the main treatment for corneal endotelial dysfunctions. However, there is a worldwide shortage of donor corneas available for transplantation and about 53% of the world’s population have no access to corneal transplantation. Generating a complete cornea by tissue engineering is still a tough goal, but an endothelial lamellar graft might be an easier task. In this study, we developed a tissue engineered corneal endothelium by culturing human corneal endothelial cells on a human purified type I collagen membrane. Human corneal endothelial cells were cultured from corneal rims after corneal penetrating keratoplasty and type I collagen was isolated from remnant cancellous bone chips. Isolated type I collagen was analyzed by western blot, liquid chromatography -mass spectrometry and quantified using the exponentially modified protein abundance index. Later on, collagen solution was casted at room temperature obtaining an optically transparent and mechanically manageable membrane that supports the growth of human and rabbit corneal endothelial cells which expressed characteristic markers of corneal endothelium: zonula ocluddens-1 and Na+/K+ ATPase. To evaluate the therapeutic efficiency of our artificial endothelial grafts, human purified type I collagen membranes cultured with rabbit corneal endothelial cells were transplanted in New Zealand white rabbits that were kept under a minimal immunosuppression regimen. Transplanted corneas maintained transparency for as long as 6 weeks without obvious edema or immune rejection and maintaining the same endothelial markers that in a healthy cornea. In conclusion, it is possible to develop an artificial human corneal endothelial graft using remnant tissues that are not employed in transplant procedures. This artificial endothelial graft can restore the integrality of corneal endothelium in an experimental model of endothelial dysfunction. This strategy could supply extra endothelial tissue and compensate the deficit of cadaveric grafts for corneal endothelial transplantation.

Verified
Journal Article
Open access
PDF file
MPMairobi Persinal-Medina
Mairobi Persinal-Medina
SLSara Llames
Sara Llames
MCManuel Chacón
Manuel Chacón
NVNatalia Vázquez
Natalia Vázquez
MLMarta Pevida López
Marta Pevida López
ÁMÁlvaro Meana
Álvaro Meana
The skin is the largest organ in the human body, comprising the main barrier against the environment. When the skin loses its integrity, it is critical to replace it to prevent water loss and the proliferation of opportunistic infections. For more than 40 years, tissue-engineered skin grafts have been based on the in vitro culture of keratinocytes over different scaffolds, requiring between 3 to 4 weeks of tissue culture before being used clinically. In this study, we describe the development of a polymerizable skin hydrogel consisting of keratinocytes and fibroblast entrapped within a fibrin scaffold. We histologically characterized the construct and evaluated its use on an in vivo wound healing model of skin damage. Our results indicate that the proposed methodology can be used to effectively regenerate skin wounds, avoiding the secondary in vitro culture steps and thus, shortening the time needed until transplantation in comparison with other bilayer skin models. This is achievable due to the instant polymerization of the keratinocytes and fibroblast combination that allows a direct application on the wound. We suggest that the polymerizable skin hydrogel is an inexpensive, easy and rapid treatment that could be transferred into clinical practice in order to improve the treatment of skin wounds.

28 October 2022 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
LFLuis Fernández-Vega-Cueto
Luis Fernández-Vega-Cueto
MPMairobi Persinal-Medina
Mairobi Persinal-Medina
NVNatalia Vázquez
Natalia Vázquez
MCManuel Chacón
Manuel Chacón
BABelén Alfonso-Bartolozzi
Belén Alfonso-Bartolozzi
ÁMÁlvaro Meana
Álvaro Meana
This study proposes a method to prepare autologous bio-based fibrin glue (FG) for use in ophthalmic surgery. FGs containing three fibrinogen concentrations and a thrombin concentrate were prepared using human blood from five donors (FG1: physiological fibrinogen concentration; FG2 and FG3: concentrated fibrinogen). The adhesion strength was tested, and the clinical safety and efficacy were studied in rabbit eyes in conjunctival surgery. A commercial FG was used as a control. From each donor, 2 mL of FG was prepared, containing 1 mL of 3.49 ± 0.78 (FG1), 17.74 ± 4.66 (FG2), or 47.46 ± 9.36 mg/mL (FG3) of fibrinogen and 1 mL of 2248.12 ± 604.20 UI/mL of thrombin. The average adhesion strength increased with the fibrinogen concentration, from 1.49 ± 0.39 kPa (FG1) to 3.14 ± 1.09 kPa (FG3). FG1 showed poor results when used for autograft adhesion. In contrast, the conjunctival autografts were successfully grafted using FG2 and FG3, revealing equivalent adhesion properties compared with commercial FG, but with less inflammation. In conclusion, FGs could be prepared on demand within minutes from small volumes of human blood, using a method that results in FGs which exhibit good adhesion capacity and are also safe and effective in a preclinical study.

9 November 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SAS. Alonso-Alonso
S. Alonso-Alonso
NVNatalia Vázquez
Natalia Vázquez
MCM. Chacón
M. Chacón
NCN. Caballero-Sánchez
N. Caballero-Sánchez
SOS. Del Olmo-Aguado
S. Del Olmo-Aguado
AMA. Meana
A. Meana
Endothelial dysfunction is a leading cause of corneal blindness in developed countries and the only available treatment is the endothelial transplantation. However, the limited availability of suitable donors remains a significant challenge, driving the exploration of alternative regenerative therapies. Advanced Therapy Medicinal Products show promise but must adhere to strict regulations that prohibit the use of animal-derived substances. This study investigates a novel culture methodology using Plasma Rich in Growth Factors (PRGF) as the only source of growth factors for primary cultures of human corneal endothelial cells (CECs). CECs were obtained from discarded corneas or endothelial rings and cultured in two different media: one supplemented with xenogeneic factors and other xenogeneic-free, using PRGF. Comprehensive characterization through immunofluorescence, morphological analyses, trans-endothelial electrical resistance measurements, RNA-seq, and qPCR was conducted on the two groups. Results demonstrate that CECs cultured in the xenogeneic-free medium exhibit comparable gene expression, morphology, and functionality to those cultured in the xenogeneic medium. Notably, PRGF-expanded CECs share 46.9% of the gene expression profile with native endothelium and express all studied endothelial markers. In conclusion, PRGF provides an effective source of xenogeneic-free growth factors for the culture of CECs from discarded corneal tissue. Further studies will be necessary to demonstrate the applicability of these cultures to cell therapies that make clinical translation possible.

20 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
MCManuel Chacón
Manuel Chacón
NVNatalia Vázquez
Natalia Vázquez
SASergio Alonso-Alonso
Sergio Alonso-Alonso
MPMairobi Persinal-Medina
Mairobi Persinal-Medina
SLSara Llames
Sara Llames
ÁMÁlvaro Meana
Álvaro Meana
The rabbit skin irritation test has been the standard for evaluating the irritation potential of chemicals; however, alternative methods that do not use animal testing are actively encouraged. Reconstructed human epidermis (RhE) models mimic the biochemical and physiological properties of the human epidermis and can be used as an alternative method. On RhE methods, the metabolic activity of RhE models is used to predict skin irritation, with a reduction in metabolic activity indicating a reduced number of viable cells and linking cell death to skin irritation processes. However, new challenges have emerged as the use of RhE models increases, including the need for non-invasive and marker-free methodologies to assess cellular states. Electrochemical impedance spectroscopy (EIS) is one such methodology that can meet these requirements. In this study, our results showed that EIS can differentiate between irritant and non-irritant chemicals, with a significant increase in the capacitance values observed in the irritant samples. A ROC curve analysis showed that the prediction method based on EIS met OECD TG 439 requirements at all time points and had 95% within-laboratory reproducibility. Comparison with the MTT viability assay showed that prediction using EIS achieved higher sensitivity, specificity, and accuracy. These results suggest that EIS could potentially replace animal testing in the evaluation of irritation potential and could be a valuable addition to in vitro testing strategies.