MANJUNATHA MAHADEVAPPA

Prof. Dr. MANJUNATHA MAHADEVAPPA

IIT Kharagpur
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2010 in IEEE Transactions on Consumer Electronics
Verified
Journal Article
Closed access
DSDebdoot Sheet
Debdoot Sheet
HGHrushikesh Garud
Hrushikesh Garud
ASAmit Suveer
Amit Suveer
MANJUNATHA MAHADEVAPPAMANJUNATHA MAHADEVAPPA
MANJUNATHA MAHADEVAPPA
JCJyotirmoy Chatterjee
Jyotirmoy Chatterjee
This paper proposes a novel modification of the brightness preserving dynamic histogram equalization technique to improve its brightness preserving and contrast enhancement abilities while reducing its computational complexity. The modified technique, called Brightness Preserving Dynamic Fuzzy Histogram Equalization (BPDFHE), uses fuzzy statistics of digital images for their representation and processing. Representation and processing of images in the fuzzy domain enables the technique to handle the inexactness of gray level values in a better way, resulting in improved performance. Execution time is dependent on image size and nature of the histogram, however experimental results show it to be faster as compared to the techniques compared here. The performance analysis of the BPDFHE along with that for BPDHE has been given for comparative evaluation.

1 May 2007 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
DYDouglas Yanai
Douglas Yanai
JWJames Weiland
James Weiland
MANJUNATHA MAHADEVAPPAMANJUNATHA MAHADEVAPPA
MANJUNATHA MAHADEVAPPA
RGRobert J. Greenberg
Robert J. Greenberg
IFIone Fine
Ione Fine
MHMark S. Humayun
Mark S. Humayun

1 June 2008 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
CBChloe´ de Balthasar
Chloe´ de Balthasar
SPSweta Patel
Sweta Patel
ARArup Roy
Arup Roy
RFRicardo Freda
Ricardo Freda
SGScott Greenwald
Scott Greenwald
IFIone Fine
Ione Fine
Purpose. The goal was to evaluate how perceptual thresholds are related to electrode impedance, electrode size, the distance of electrodes from the retinal surface, and retinal thickness in six subjects blind as a result of retinitis pigmentosa, who received epiretinal prostheses implanted monocularly as part of a U.S. Food and Drug Administration (FDA)–approved clinical trial. methods. The implant consisted of an extraocular unit containing electronics for wireless data, power recovery, and generation of stimulus current, and an intraocular unit containing 16 platinum stimulating electrodes (260- or 520-μm diameter) arranged in a 4 × 4 pattern. The electrode array was held onto the retina by a small tack. Stimulation was controlled by a computer-based external system that allowed independent control over each electrode. Perceptual thresholds (the current necessary to see a percept on 79% of trials) and impedance were measured for each electrode on a biweekly basis. The distance of electrodes from the retinal surface and retinal thickness were measured by optical coherence tomography on a less regular basis. results. Stimulation thresholds for detecting phosphenes correlated with the distance of the electrodes from the retinal surface, but not with electrode size, electrode impedance, or retinal thickness. conclusions. Maintaining close proximity between the electrode array and the retinal surface is critical in developing a successful retinal implant. With the development of chronic electrode arrays that are stable and flush on the retinal surface, it is likely that the influence of other factors such as electrode size, retinal degeneration, and subject age will become more apparent. (ClinicalTrials.gov number, NCT00279500.)

13 June 2005 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
MANJUNATHA MAHADEVAPPAMANJUNATHA MAHADEVAPPA
MANJUNATHA MAHADEVAPPA
JWJames Weiland
James Weiland
DYD. Yanai
D. Yanai
IFI. Fine
I. Fine
RGR.J. Greenberg
R.J. Greenberg
MHM.S. Humayun
M.S. Humayun
Three test subjects blind from retinitis pigmentosa were implanted with retinal prostheses as part of a FDA-approved clinical trial. The implant consisted of an extraocular unit that contained electronics for wireless data, power, and generation of stimulus current, and an intraocular unit that consisted of 16 platinum stimulating electrodes arranged in a 4 /spl times/ 4 pattern within a silicone rubber substrate. The array was held to the retina by a small tack. The stimulator was connected to the array by a multiwire cable and was controlled by a computer based external system that allowed precise control over each electrode. Perception thresholds and electrode impedance were obtained on each electrode from the subjects over several months of testing. The electrode distance from the retina was determined from optical coherence tomography imaging of the array and retina. Across all subjects, average thresholds ranged from 24-702 /spl mu/A (1-ms pulse). The data show that proximity to the retina played a role in determining the threshold and impedance, but only for electrodes that were greater than 0.5 mm from the retina.

22 December 2011 in NeuroRehabilitation
Verified
Journal Article
Closed access
PDF file
SSSukanta K. Sabut
Sukanta K. Sabut
CSChhanda Sikdar
Chhanda Sikdar
RKRatnesh Kumar
Ratnesh Kumar
MANJUNATHA MAHADEVAPPAMANJUNATHA MAHADEVAPPA
MANJUNATHA MAHADEVAPPA
Objective: To evaluate the therapeutic effects of Functional Electrical Stimulation (FES) of the tibialis anterior muscle on plantarflexor spasticity, dorsiflexor strength, voluntary ankle dorsiflexion, and lower extremity motor recovery with stroke

1 January 2010 in Disability and Rehabilitation
Verified
Journal Article
Closed access
PDF file
SSSukanta K. Sabut
Sukanta K. Sabut
CSChanda Sikdar
Chanda Sikdar
RMRamkrishna Mondal
Ramkrishna Mondal
RKRatnesh Kumar
Ratnesh Kumar
MANJUNATHA MAHADEVAPPAMANJUNATHA MAHADEVAPPA
MANJUNATHA MAHADEVAPPA
Purpose. To evaluate the clinical efficacy of functional electrical stimulation (FES) therapy of the tibialis anterior (TA) muscle on gait restoration and enhancing motor recovery with stroke patients. Method. Thirty hemiparetic participants with spastic foot-drop impairments who were at least 3 months post-stroke were recruited from a rehabilitation institute and were assigned either to a control group or a FES group. Both the groups participated in a conventional stroke rehabilitation program for 60 min per day, 5 days a week, for 12-weeks. The FES group received the electrical stimulation to the TA muscle for correction of foot-drop. Results. Functional electric stimulation (FES) resulted in a 26.3% (p < 0.001) improvement of walking speed measured with 10-m walkway, whereas the improvement in the control group was only 11.5% (p < 0.01). The FES group also showed significantly greater improvements compared to control group in other gait parameters (e.g. cadence, step length), physiological cost index (PCI), ankle range of motion, spasticity of calf muscle, Fugl–Meyer scores, and the maximum value of the root mean square (RMSmax), which reflects the capacity of the muscle output. Conclusions. These findings suggest that, the FES therapy combined with conventional therapy treatment more effectively improves the walking ability and enhances the motor recovery when compared with conventional therapy alone in stroke survivors.