Julia Mader

Dr. Julia Mader

Medical University of Graz - Department of Endocrinology and Diabetology
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2015 in New England Journal of Medicine
Verified
Journal Article
Closed access
PDF file
HTHood Thabit
Hood Thabit
MTMartin Tauschmann
Martin Tauschmann
JAJanet M. Allen
Janet M. Allen
LLLalantha H. Leelarathna
Lalantha H. Leelarathna
SHSara Hartnell
Sara Hartnell
RHRoman Hovorka
Roman Hovorka
The feasibility, safety, and efficacy of prolonged use of an artificial beta cell (closed-loop insulin-delivery system) in the home setting have not been established. In two multicenter, crossover, randomized, controlled studies conducted under free-living home conditions, we compared closed-loop insulin delivery with sensor-augmented pump therapy in 58 patients with type 1 diabetes. The closed-loop system was used day and night by 33 adults and overnight by 25 children and adolescents. Participants used the closed-loop system for a 12-week period and sensor-augmented pump therapy (control) for a similar period. The primary end point was the proportion of time that the glucose level was between 70 mg and 180 mg per deciliter for adults and between 70 mg and 145 mg per deciliter for children and adolescents. Among adults, the proportion of time that the glucose level was in the target range was 11.0 percentage points (95% confidence interval [CI], 8.1 to 13.8) greater with the use of the closed-loop system day and night than with control therapy (P<0.001). The mean glucose level was lower during the closed-loop phase than during the control phase (difference, −11 mg per deciliter; 95% CI, −17 to −6; P<0.001), as were the area under the curve for the period when the glucose level was less than 63 mg per deciliter (39% lower; 95% CI, 24 to 51; P<0.001) and the mean glycated hemoglobin level (difference, −0.3%; 95% CI, −0.5 to −0.1; P=0.002). Among children and adolescents, the proportion of time with the nighttime glucose level in the target range was higher during the closed-loop phase than during the control phase (by 24.7 percentage points; 95% CI, 20.6 to 28.7; P<0.001), and the mean nighttime glucose level was lower (difference, −29 mg per deciliter; 95% CI, −39 to −20; P<0.001). The area under the curve for the period in which the day-and-night glucose levels were less than 63 mg per deciliter was lower by 42% (95% CI, 4 to 65; P=0.03). Three severe hypoglycemic episodes occurred during the closed-loop phase when the closed-loop system was not in use. Among patients with type 1 diabetes, 12-week use of a closed-loop system, as compared with sensor-augmented pump therapy, improved glucose control, reduced hypoglycemia, and, in adults, resulted in a lower glycated hemoglobin level. (Funded by the JDRF and others; [email protected] and APCam08 ClinicalTrials.gov numbers, NCT01961622 and NCT01778348.)

29 March 2022 in Journal of Diabetes Science and Technology
Verified
Journal Article
Closed access
DKDavid C. Klonoff
David C. Klonoff
JWJing Wang
Jing Wang
DRDavid Rodbard
David Rodbard
MKMichael A. Kohn
Michael A. Kohn
CLChengdong Li
Chengdong Li
BKBoris Kovatchev
Boris Kovatchev
Background: A composite metric for the quality of glycemia from continuous glucose monitor (CGM) tracings could be useful for assisting with basic clinical interpretation of CGM data. Methods: We assembled a data set of 14-day CGM tracings from 225 insulin-treated adults with diabetes. Using a balanced incomplete block design, 330 clinicians who were highly experienced with CGM analysis and interpretation ranked the CGM tracings from best to worst quality of glycemia. We used principal component analysis and multiple regressions to develop a model to predict the clinician ranking based on seven standard metrics in an Ambulatory Glucose Profile: very low–glucose and low-glucose hypoglycemia; very high–glucose and high-glucose hyperglycemia; time in range; mean glucose; and coefficient of variation. Results: The analysis showed that clinician rankings depend on two components, one related to hypoglycemia that gives more weight to very low-glucose than to low-glucose and the other related to hyperglycemia that likewise gives greater weight to very high-glucose than to high-glucose. These two components should be calculated and displayed separately, but they can also be combined into a single Glycemia Risk Index (GRI) that corresponds closely to the clinician rankings of the overall quality of glycemia (r = 0.95). The GRI can be displayed graphically on a GRI Grid with the hypoglycemia component on the horizontal axis and the hyperglycemia component on the vertical axis. Diagonal lines divide the graph into five zones (quintiles) corresponding to the best (0th to 20th percentile) to worst (81st to 100th percentile) overall quality of glycemia. The GRI Grid enables users to track sequential changes within an individual over time and compare groups of individuals. Conclusion: The GRI is a single-number summary of the quality of glycemia. Its hypoglycemia and hyperglycemia components provide actionable scores and a graphical display (the GRI Grid) that can be used by clinicians and researchers to determine the glycemic effects of prescribed and investigational treatments.

20 January 2022 in New England Journal of Medicine
Verified
Journal Article
Closed access
PDF file
JWJulia Ware
Julia Ware
JAJanet M. Allen
Janet M. Allen
CBCharlotte K. Boughton
Charlotte K. Boughton
MWMalgorzata E. Wilinska
Malgorzata E. Wilinska
SHSara Hartnell
Sara Hartnell
RHRoman Hovorka
Roman Hovorka
The possible advantage of hybrid closed-loop therapy (i.e., artificial pancreas) over sensor-augmented pump therapy in very young children with type 1 diabetes is unclear. In this multicenter, randomized, crossover trial, we recruited children 1 to 7 years of age with type 1 diabetes who were receiving insulin-pump therapy at seven centers across Austria, Germany, Luxembourg, and the United Kingdom. Participants received treatment in two 16-week periods, in random order, in which the closed-loop system was compared with sensor-augmented pump therapy (control). The primary end point was the between-treatment difference in the percentage of time that the sensor glucose measurement was in the target range (70 to 180 mg per deciliter) during each 16-week period. The analysis was conducted according to the intention-to-treat principle. Key secondary end points included the percentage of time spent in a hyperglycemic state (glucose level, >180 mg per deciliter), the glycated hemoglobin level, the mean sensor glucose level, and the percentage of time spent in a hypoglycemic state (glucose level, <70 mg per deciliter). Safety was assessed. A total of 74 participants underwent randomization. The mean (±SD) age of the participants was 5.6±1.6 years, and the baseline glycated hemoglobin level was 7.3±0.7%. The percentage of time with the glucose level in the target range was 8.7 percentage points (95% confidence interval [CI], 7.4 to 9.9) higher during the closed-loop period than during the control period (P<0.001). The mean adjusted difference (closed-loop minus control) in the percentage of time spent in a hyperglycemic state was −8.5 percentage points (95% CI, −9.9 to −7.1), the difference in the glycated hemoglobin level was −0.4 percentage points (95% CI, −0.5 to −0.3), and the difference in the mean sensor glucose level was −12.3 mg per deciliter (95% CI, −14.8 to −9.8) (P<0.001 for all comparisons). The time spent in a hypoglycemic state was similar with the two treatments (P=0.74). The median time spent in the closed-loop mode was 95% (interquartile range, 92 to 97) over the 16-week closed-loop period. One serious adverse event of severe hypoglycemia occurred during the closed-loop period. One serious adverse event that was deemed to be unrelated to treatment occurred. A hybrid closed-loop system significantly improved glycemic control in very young children with type 1 diabetes, without increasing the time spent in hypoglycemia. (Funded by the European Commission and others; ClinicalTrials.gov number, NCT03784027.)

13 October 2020 in Diabetologia
Verified
Journal Article
Open access
PDF file
OMOthmar Moser
Othmar Moser
MRMichael C Riddell
Michael C Riddell
MEMax L Eckstein
Max L Eckstein
PAPeter Adolfsson
Peter Adolfsson
RRRémi Rabasa-Lhoret
Rémi Rabasa-Lhoret
Julia MaderJulia Mader
Julia Mader
Physical exercise is an important component in the management of type 1 diabetes across the lifespan. Yet, acute exercise increases the risk of dysglycaemia, and the direction of glycaemic excursions depends, to some extent, on the intensity and duration of the type of exercise. Understandably, fear of hypoglycaemia is one of the strongest barriers to incorporating exercise into daily life. Risk of hypoglycaemia during and after exercise can be lowered when insulin-dose adjustments are made and/or additional carbohydrates are consumed. Glycaemic management during exercise has been made easier with continuous glucose monitoring (CGM) and intermittently scanned continuous glucose monitoring (isCGM) systems; however, because of the complexity of CGM and isCGM systems, both individuals with type 1 diabetes and their healthcare professionals may struggle with the interpretation of given information to maximise the technological potential for effective use around exercise (i.e. before, during and after). This position statement highlights the recent advancements in CGM and isCGM technology, with a focus on the evidence base for their efficacy to sense glucose around exercise and adaptations in the use of these emerging tools, and updates the guidance for exercise in adults, children and adolescents with type 1 diabetes. Graphical abstract

1 June 2015 in Hypertension
Verified
Journal Article
Open access
PDF file
Stefan PilzStefan Pilz
Stefan Pilz
MGMartin Gaksch
Martin Gaksch
KKKatharina Kienreich
Katharina Kienreich
MGMartin Robert Grübler
Martin Robert Grübler
NVNicolas Verheyen
Nicolas Verheyen
ATAndreas Tomaschitz
Andreas Tomaschitz
Vitamin D deficiency is a risk factor for arterial hypertension, but randomized controlled trials showed mixed effects of vitamin D supplementation on blood pressure (BP). We aimed to evaluate whether vitamin D supplementation affects 24-hour systolic ambulatory BP monitoring values and cardiovascular risk factors. The Styrian Vitamin D Hypertension Trial is a single-center, double-blind, placebo-controlled study conducted from June 2011 to August 2014 at the endocrine outpatient clinic of the Medical University of Graz, Austria. We enrolled 200 study participants with arterial hypertension and 25-hydroxyvitamin D levels below 30 ng/mL. Study participants were randomized to receive either 2800 IU of vitamin D3 per day as oily drops (n=100) or placebo (n=100) for 8 weeks. Primary outcome measure was 24-hour systolic BP. Secondary outcome measures were 24-hour diastolic BP, N-terminal-pro-B-type natriuretic peptide, QTc interval, renin, aldosterone, 24-hour urinary albumin excretion, homeostasis model assessment-insulin resistance, triglycerides, high-density lipoprotein cholesterol, and pulse wave velocity. A total of 188 participants (mean [SD] age, 60.1 [11.3] years; 47% women; 25-hydroxyvitamin D, 21.2 [5.6] ng/mL) completed the trial. The mean treatment effect (95% confidence interval) for 24-hour systolic BP was −0.4 (−2.8 to 1.9) mm Hg ( P =0.712). Triglycerides increased significantly (mean change [95% confidence interval], 17 [1–33] mg/dL; P =0.013), but no further significant effects were observed for secondary outcomes. Vitamin D supplementation in hypertensive patients with low 25-hydroxyvitamin D has no significant effect on BP and several cardiovascular risk factors, but it was associated with a significant increase in triglycerides. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT02136771.

1 April 2017 in The Lancet Diabetes & Endocrinology
Verified
Journal Article
Open access
Lia BallyLia Bally
Lia Bally
HTHood Thabit
Hood Thabit
HKHarald Kojzar
Harald Kojzar
Julia MaderJulia Mader
Julia Mader
JQJehona Qerimi-Hyseni
Jehona Qerimi-Hyseni
RHRoman Hovorka
Roman Hovorka
Tight control of blood glucose concentration in people with type 1 diabetes predisposes to hypoglycaemia. We aimed to investigate whether day-and-night hybrid closed-loop insulin delivery can improve glucose control while alleviating the risk of hypoglycaemia in adults with HbA1c below 7·5% (58 mmol/mol). In this open-label, randomised, crossover study, we recruited adults (aged ≥18 years) with type 1 diabetes and HbA1c below 7·5% from Addenbrooke's Hospital (Cambridge, UK) and Medical University of Graz (Graz, Austria). After a 2-4 week run-in period, participants were randomly assigned (1:1), using web-based randomly permuted blocks of four, to receive insulin via the day-and-night hybrid closed-loop system or usual pump therapy for 4 weeks, followed by a 2-4 week washout period and then the other intervention for 4 weeks. Treatment interventions were unsupervised and done under free-living conditions. During the closed-loop period, a model-predictive control algorithm directed insulin delivery, and prandial insulin delivery was calculated with a standard bolus wizard. The primary outcome was the proportion of time when sensor glucose concentration was in target range (3·9-10·0 mmol/L) over the 4 week study period. Analyses were by intention to treat. This study is registered with ClinicalTrials.gov, number NCT02727231, and is completed. Between March 21 and June 24, 2016, we recruited 31 participants, of whom 29 were randomised. One participant withdrew during the first closed-loop period because of dissatisfaction with study devices and glucose control. The proportion of time when sensor glucose concentration was in target range was 10·5 percentage points higher (95% CI 7·6-13·4; p<0·0001) during closed-loop delivery compared with usual pump therapy (65·6% [SD 8·1] when participants used usual pump therapy vs 76·2% [6·4] when they used closed-loop). Compared with usual pump therapy, closed-loop delivery also reduced the proportion of time spent in hypoglycaemia: the proportion of time with glucose concentration below 3·5 mmol/L was reduced by 65% (53-74, p<0·0001) and below 2·8 mmol/L by 76% (59-86, p<0·0001). No episodes of serious hypoglycaemia or other serious adverse events occurred. Use of day-and-night hybrid closed-loop insulin delivery under unsupervised, free-living conditions for 4 weeks in adults with type 1 diabetes and HbA1c below 7·5% is safe and well tolerated, improves glucose control, and reduces hypoglycaemia burden. Larger and longer studies are warranted. Swiss National Science Foundation (P1BEP3_165297), JDRF, UK National Institute for Health Research Cambridge Biomedical Research Centre, and Wellcome Strategic Award (100574/Z/12/Z).