The diagnostic value of ultrasonography (US) for frozen shoulder (FS) is not well established. This study aimed to assess the diagnostic value of US measurement of inferior joint capsule (IJC) thickness and evaluate changes in the thickness of the IJC by US depending on arm position. A total of 71 patients with clinically diagnosed unilateral FS who underwent bilateral US measurement of the IJC were enrolled in this study. The US measurement of the IJC was performed with a linear transducer positioned around the anterior axillary line with the shoulder 40° abducted and with neutral rotation of the glenohumeral joint (neutral position). We also measured the IJC thickness in the externally rotated and internally rotated positions with the shoulder 40° abducted. In the neutral position, as well as in the internally rotated and externally rotated positions, the thickness of the IJC on US was significantly higher in the affected shoulder than that in the unaffected shoulder (all p < 0.001). On both the affected and unaffected sides, the US thickness of the IJC in the neutral position was significantly higher than that in the externally rotated position (p < 0.001), but lower than that in the internally rotated position (p < 0.001). Regarding IJC thickness in the neutral position, a 3.2-mm cutoff value yielded the highest diagnostic accuracy for FS, with a sensitivity and specificity of 73.2% and 77.5%, respectively. The area under the curve for IJC thickness was 0.824 (95% confidence interval, 0.76–0.89). US measurement of the IJC in the neutral position yielded good diagnostic accuracy for FS. Because IJC thickness is affected by arm rotation, it is important to measure the IJC thickness in a standardized posture to ensure diagnostic value.
31 December 2022 in Journal of Electrodiagnosis and Neuromuscular Diseases
Objective: We investigated the factors affecting electrodiagnostic (EDX) parameters after carpal tunnel release (CTR).Methods: Thirty-nine cases with clinically diagnosed carpal tunnel syndrome who received CTR and EDX studies before and after CTR were enrolled in this study. We analyzed EDX parameters such as distal onset latency and the amplitude of median compound motor action potentials (CMAPs) and sensory nerve action potentials (SNAPs).Results: Among 39 cases, 24 (61.5%) showed improvement of at least 1 grade, based on Bland’s scale, after CTR. Follow-up EDX studies were performed 6 to 36 months after CTR. Improvement on Bland’s scale was shown in 50% of patients who received follow-up EDX studies at 6 and 12 months after CTR and in all patients who received follow-up at 24 and 36 months. The EDX parameters showed significant recovery. Younger patients showed greater recovery of SNAP amplitude (p = 0.021, r = -0.369) after CTR. The preoperative severe group showed greater recovery of CMAP (both amplitude and latency) than the non-severe group (p = 0.011 and p = 0.038, respectively).Conclusion: We confirmed the effectiveness of CTR through EDX studies. Age and preoperative EDX severity can affect the recovery of EDX parameters after CTR.
About Me
Resident of Rehabilitation Medicine, Chung-Ang University Hospital, Seoul, South Korea
Resident of Rehabilitation Medicine, Chung-Ang University Hospital, Seoul, South Korea