Julián García-Feijóo

Dr. Julián García-Feijóo


Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2008 in Artificial Intelligence in Medicine
Verified
Journal Article
Closed access
Enrique J. CarmonaEnrique J. Carmona
Enrique J. Carmona
MRMariano Rincon
Mariano Rincon
JGJulián García-Feijóo
Julián García-Feijóo
Jose M Martinez de la CasaJose M Martinez de la Casa
Jose M Martinez de la Casa

1 July 2015 in Ophthalmology
Verified
Journal Article
Closed access
NPNorbert Pfeiffer
Norbert Pfeiffer
JGJulián García-Feijóo
Julián García-Feijóo
Jose M Martinez de la CasaJose M Martinez de la Casa
Jose M Martinez de la Casa
JLJose M. Larrosa
Jose M. Larrosa
AFAntonio Fea
Antonio Fea
TSThomas W. Samuelson
Thomas W. Samuelson

23 January 2014 in Advances in Therapy
Verified
Journal Article
Open access
PDF file
LVLilit Voskanyan
Lilit Voskanyan
JGJulián García-Feijóo
Julián García-Feijóo
JBJose I. Belda
Jose I. Belda
AFAntonio Fea
Antonio Fea
AJAnselm Jünemann
Anselm Jünemann
CBChristophe Baudouin
Christophe Baudouin
Introduction Micro-invasive glaucoma surgical implantation of trabecular micro-bypass stents, previously shown to be safe and effective for open-angle glaucoma (OAG) subjects during cataract surgery, was considered for evaluation as a sole procedure. The aim of this study was to evaluate the safety and intraocular pressure (IOP)-lowering efficacy after ab interno implantation of two Glaukos Trabecular Micro-Bypass iStent inject second generation devices in subjects with OAG. This study was performed at sites in France, Germany, Italy, Republic of Armenia, and Spain. Methods In this pan-European, multi-center prospective, post-market, unmasked study, 99 patients with OAG on at least two topical ocular hypotensive medications who required additional IOP lowering to control glaucoma disease underwent implantation of two GTS400 stents in a stand-alone procedure. Patients were qualified if they presented with preoperative mean IOP between 22 and 38 mmHg after medication washout. Postoperatively, subjects were assessed at Day 1, Months 1, 3, 6, 7, 9, and 12. IOP, medication use and safety were assessed at each visit. Results Sixty-six percent of subjects achieved IOP ≤18 mmHg at 12 months without medication, and 81% of subjects achieved Month 12 IOP ≤ 18 mmHg with either a single medication or no medication. Mean baseline washout IOP values decreased by 10.2 mmHg or 39.7% from 26.3 (SD 3.5) mmHg to 15.7 (SD 3.7) mmHg at Month 12. Mean IOP at 12 months was 14.7 (SD 3.1) mmHg in subjects not using ocular hypotensive medications. Reduction from preoperative medication burden was achieved in 86.9% of patients, including 15.2% with reduction of one medication and 71.7% with reduction of two or more medications. Postoperative complications occurred at a low rate and resolved without persistent effects. Conclusion In this series, implantation of two trabecular micro-bypass second generation stents in subjects with OAG resulted in IOP and medication reduction and favorable safety outcomes.

1 December 2005 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
Jose M Martinez de la CasaJose M Martinez de la Casa
Jose M Martinez de la Casa
JGJulián García-Feijóo
Julián García-Feijóo
ACAlfredo Castillo
Alfredo Castillo
JGJulian Garcia-Sanchez
Julian Garcia-Sanchez
Purpose. To establish the reproducibility of a rebound tonometer in humans and the effect of corneal thickness on measurements, comparing it with Goldmann applanation tonometer.

1 January 2001 in Ophthalmology
Verified
Journal Article
Closed access
IJIgnacio Jiménez-Alfaro
Ignacio Jiménez-Alfaro
JCJosé M Benı́tez del Castillo
José M Benı́tez del Castillo
JGJulián García-Feijóo
Julián García-Feijóo
JBJavier G Gil de Bernabé
Javier G Gil de Bernabé
JIJosé M Serrano de la Iglesia
José M Serrano de la Iglesia

23 January 2012 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
PVPedro Arriola Villalobos
Pedro Arriola Villalobos
Jose M Martinez de la CasaJose M Martinez de la Casa
Jose M Martinez de la Casa
DVDAVID DIAZ VALLE
DAVID DIAZ VALLE
CPCristina Fernandez Perez
Cristina Fernandez Perez
JGJulián García-Sánchez
Julián García-Sánchez
JGJulián García-Feijóo
Julián García-Feijóo
Aims To evaluate the long-term efficacy and safety of combined cataract surgery and Glaukos iStent implantation for coexistent open-angle glaucoma and cataract. Methods Prospective, non-comparative, uncontrolled, non-randomised, interventional case series study. Subjects older than 18 years with coexistent uncontrolled mild or moderate open-angle glaucoma (including pseudoexfoliative and pigmentary) and cataract underwent phacoemulsification and intraocular lens implantation along with ab-interno gonioscopically guided implantation of one Glaukos iStent. The variables recorded during a minimum of 3 years of follow-up were: intraocular pressure (IOP), number of antiglaucoma medications and best-corrected visual acuity. Results The 19 patients enrolled were 58–88 years old (mean age 74.6±8.44 years). Mean follow-up was 53.68±9.26 months. Mean IOP was reduced from 19.42±1.89 mm Hg to 16.26±4.23 mm Hg (p=0.002) at the end of follow up, indicating a 16.33% decrease in IOP. The mean number of pressure-lowering medications used by the patients fell from 1.32±0.48 to 0.84±0.89 (p=0.046). In 42% of patients, no antiglaucoma medications were used at the end of follow-up. Mean best-corrected visual acuity significantly improved from 0.29±0.13 to 0.62±0.3 (p<0.001). No complications of surgery were observed. Conclusion Combined cataract surgery and Glaukos iStent implantation seems to be an effective and safe procedure to treat coexistent open-angle glaucoma and cataract.