Many fabrics and clothing ‘systems’ have been designed to enhance heat balance and provide greater thermal comfort for the wearer. However, studies on the effects of socks have largely been ignored in clothing research. It has been suggested that the thermal state of the extremities may alter core temperature and mental stress may be a major determinant of skin blood perfusion on the foot. However, no definite conclusions have been drawn. The aim of this study was to examine the effects of two different sock types on foot skin temperature and to investigate any impact on whole body thermoregulation and energy expenditure. Sixteen subjects carried out two sessions of treadmill running exercise, one session wearing a standard running sock and one session wearing an ergonomic asymmetric fitted sock. The overall mean heart rate, core (aural) temperature, foot skin temperature, weighted mean skin temperature and sweat rate during exercise were not statistically significant between the sock conditions (p > 0.05). There was a consistent trend in all participants for the ergonomic sock to induce a higher core temperature and higher skin temperatures compared to the standard sock. Overall mean ratings of perceived exertion and ratings of thermal perception were similar for both sock conditions. Participant questionnaires highlighted a general perception that the ergonomic socks had superior cushioning but that the standard socks were comfortable to wear. Despite there being no significant physiological or thermal differences between socks, the ergonomic sock was perceived to be cooler and was the preferred sock which suggests that subjective perceptions may be more important than objective measurements when selecting a sock for wear during prolonged exercise.
2 July 2022 in Journal of University Teaching and Learning Practice
This editorial describes some of the current and emerging challenges in peer review for the academic publishing system. Peer review is a fundamental element of academic research and publishing, with a firm reliance on the global scholarly community to perform gatekeeping and filtering processes in pursuing high-quality and high-value scholarly publications: the “gold standard” in academic publishing. We begin with examples of several contemporary challenges the peer review system poses, including impartiality and bias, academic reward structures, fake peer reviews, and reviewer fatigue. To further understand these challenges, we then provide a brief history of the evolution of the peer review system, focusing on the traditional forms of pre-publication peer review so familiar to the communication of scholarly work. Against this backdrop, we consider the benefits of peer review that span the continuum of the academic community – from authors to reviewers to journals and research communities. But many traditional forms of peer review are being challenged by new and innovative processes, systems and platforms. Finally, we look at how others have re-envisioned the peer review process during this phase of rapid evolution in journal publishing, with a strong call for quality and integrity in writing peer reviews. We conclude by suggesting ways forward for embedding sustainability, equity, and respect within the peer review process as an active force for advancing scholarship.
1 March 2014 in Journal of Strength & Conditioning Research
Uring exercise in hot environments. The purpose of this investigation was to assess the interday reliability of intestinal temperature during an exercise-heat challenge. Intestinal temperature was recorded as 12 physically active men (25 ± 4 years, stature 181.7 ± 7.0 cm, body mass 81.1 ± 10.6 kg) performed two 60-minute bouts of recumbent cycling (50% of peak aerobic power [watts]) in an environmental chamber set at 35° C 50% relative humidity 3–10 days apart. A range of statistics were used to calculate the reliability, including a paired t-test, 95% limits of agreement (LOA), coefficient of variation (CV), standard error of measurement (SEM), Pearson's correlation coefficient (r), intraclass correlation coefficient (ICC), and Cohen's d. Statistical significance was set at p ≤ 0.05. The method indicated a good overall reliability (LOA = ±0.61° C, CV = 0.58%, SEM = 0.12° C, Cohen's d = 0.12, r = 0.84, ICC = 0.84). Analysis revealed a statistically significant (p = 0.02) mean systematic bias of −0.07 ± 0.31° C, and the investigation of the Bland–Altman plot suggested the presence of heteroscedasticity. Further analysis revealed the minimum “likely” change in intestinal temperature to be 0.34° C. Although the method demonstrates a good reliability, researchers should be aware of heteroscedasticity. Changes in intestinal temperature >0.34° C as a result of exercise or an intervention in a hot environment are likely changes and less influenced by error associated with the method....
The purpose of this study was to quantify physiological and perceptual responses to hand immersion in water during recumbent cycling in a hot environment. Seven physically active males (body mass 79.8 ± 6.3 kg; stature 182 ± 5 cm; age 23 ± 3 years) immersed their hands in 8, 14 and 34°C water whilst cycling at an intensity (W) equivalent to 50% O2peak for 60 min in an environmental chamber (35°C, 50% relative humidity). 8 and 14°C water attenuated an increase in body temperature, and lowered cardiorespiratory and skin blood flow demands. These effects were considered to be practically beneficial (standardised effect size > 0.20). There was a tendency for 8 and 14°C to extend exercise duration versus 34°C (>7%). Heart rate, intestinal, mean skin and mean body temperature were less in 8°C compared to 14°C; these differences were considered practically beneficial. Augmented heat loss at the palm-water surface might enable cooler blood to return to the body and limit physiological strain. These findings provide a mechanistic basis for continuous hand cooling and indicate that endurance exercise in hot environments could be improved using this method. Future research should investigate its effectiveness during cycling and running performance.
1 February 2011 in Innovations in Education and Teaching International
A level 6 module was developed in order to implement innovative assessment strategies and encourage higher level learning. The module tutor (one of this paper’s authors) was seconded from teaching duties (40%) to the University’s academic development unit to work on the module transformation. The rationale for the redesign of the assessment strategy was to enhance the student learning experience whilst taking an innovative approach to computer aided learning and assessment. Information technology enabled assessment strategies and ways of using computer based assessment in higher level learning were examined. The redesigned module has been delivered two years running, and the students’ experience of the module evaluated following the final taught session each year. This paper outlines the experiences of the learners and the tutor and considers the potential for future development of blended learning and assessment.