There is scarce and conflicting evidence on the comparison between endoscopic ultrasound (EUS) and percutaneous (PC)-guided liver biopsy (LB). The aim of this study was to compare the two approaches in a series of patients with parenchymal and focal liver lesions. Fifty-four patients undergoing EUS-LB in two high-volume centers between 2017 and 2021 were compared to 62 patients who underwent PC-LB. The primary outcome was diagnostic adequacy rate. The secondary outcomes were diagnostic accuracy, total sample length (TSL), number of complete portal tracts (CPTs), procedural duration, and adverse events. Variables were compared using the Chi-square and Mann–Whitney test. Median age was 56 years (interquartile range 48–69) in the EUS-LB group and 54 years (45–67) in the PC-LB group with most patients being male. Indication for LB was due to parenchymal disease in 50% of patients, whereas the other patients underwent LB due to focal liver lesions. Diagnostic adequacy was 100% in PC-LB and 94.4% in the EUS-LB group (p = 0.74), whereas diagnostic accuracy was 88.8% in the EUS-LB group and 100% in the PC-LB group (p = 0.82). Median TSL was significantly greater in the PC-LB group (27.4 mm, IQR 21–29) when compared to the EUS-LB group (18.5 mm, 10.1–22.4; p = 0.02). The number of complete portal tracts was 21 (11–24) in the PC-LB group and 18.5 (10–23.2) in EUS-LB group (p = 0.09). EUS-LB was a significantly longer procedure (7 min, 5–11 versus 1 min, 1–3 of PC-LB; p < 0.001) and no evidence of adverse events was observed in any of the study groups. These results were confirmed in the subgroup analysis performed according to an indication for LB (parenchymal disease versus focal lesion). Although PC-LB yielded specimens with greater TSL, diagnostic adequacy and accuracy were similar between the two procedures.
Gastrointestinal Stromal Tumors (GISTs) are subepithelial lesions (SELs) that commonly develop in the gastrointestinal tract. GISTs, unlike other SELs, can exhibit malignant behavior, so differential diagnosis is critical to the decision-making process. Endoscopic ultrasound (EUS) is considered the most accurate imaging method for diagnosing and differentiating SELs in the gastrointestinal tract by assessing the lesions precisely and evaluating their malignant risk. Due to their overlapping imaging characteristics, endosonographers may have difficulty distinguishing GISTs from other SELs using conventional EUS alone, and the collection of tissue samples from these lesions may be technically challenging. Even though it appears to be less effective in the case of smaller lesions, histology is now the gold standard for achieving a final diagnosis and avoiding unnecessary and invasive treatment for benign SELs. The use of enhanced EUS modalities and elastography has improved the diagnostic ability of EUS. Furthermore, recent advancements in artificial intelligence systems that use EUS images have allowed them to distinguish GISTs from other SELs, thereby improving their diagnostic accuracy.
Background: Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) using lumen apposing metal stent has emerged as a minimally invasive treatment for the management of malignant gastric outlet obstruction (mGOO). We aimed to compare EUS-GE with enteral stenting (ES) for the treatment of mGOO. Methods: Patients who underwent EUS-GE or ES for mGOO between June 2017 and June 2023 at two Italian centers were retrospectively identified. The primary outcome was stent dysfunction. Secondary outcomes included technical success, clinical failure, safety, and hospital length of stay. A propensity score-matching analysis was performed using multiple covariates. Results: Overall, 198 patients were included (66 EUS-GE and 132 ES). The stent dysfunction rate was 3.1% and 16.9% following EUS-GE and ES, respectively (p = 0.004). Using propensity score-matching, 45 patients were allocated to each group. The technical success rate was 100% for both groups. Stent dysfunction was higher in the ES group compared with the EUS-GE group (20% versus 4.4%, respectively; p = 0.022) without differences in clinical efficacy (p = 0.266) and safety (p = 0.085). A significantly shorter hospital stay was associated with EUS-GE compared with ES (7.5 ± 4.9 days vs. 12.5 ± 13.0 days, respectively; p = 0.018). Kaplan–Meier analyses confirmed a higher stent dysfunction-free survival rate after EUS-GE compared with ES (log-rank test; p = 0.05). Conclusion: EUS-GE offers lower rates of stent dysfunction, longer stent patency, and shorter hospital stay compared with ES.
Endoscopic ultrasound (EUS)-guided tissue sampling includes the techniques of fine needle aspiration (FNA) and fine needle biopsy (FNB), and both procedures have revolutionized specimen collection from the gastrointestinal tract, especially from remote/inaccessible organs. EUS-FNB has replaced FNA as the procedure of choice for tissue acquisition in solid pancreatic lesions (SPLs) across various society guidelines. FNB specimens provide a larger histological tissue core (preserving tissue architecture) with fewer needle passes, and this is extremely relevant in today’s era of precision and personalized molecular medicine. Innovations in needle tip design are constantly under development to maximize diagnostic accuracy by enhancing histological sampling capabilities. But, apart from the basic framework of the needle, various other factors play a role that influence diagnostic outcomes, namely, sampling techniques (fanning, aspiration or suction, and number of passes), collection methods, on-site evaluation (rapid, macroscopic, or visual), and specimen processing. The choice taken depends strongly on the endoscopist’s preference, available resources at the disposal, and procedure objectives. Hence, in this review, we explicate in detail the concepts and available literature at our disposal on the topic of EUS-guided pancreatic tissue sampling to best guide any practicing gastroenterologist/endoscopist in a not-to-ideal set-up, which EUS-guided tissue acquisition technique is the “best” for their case to augment their diagnostic outcomes.
12 January 2024 in United European Gastroenterology Journal
Objectives: Type 2 is a rare form of autoimmune pancreatitis (AIP). Despite being considered a benign disease, only few studies with limited sample size and short follow‐up have been published on type 2 AIP. The aim of this observational study was to evaluate long‐term outcomes, such as the risk of relapse, pancreatic insufficiency and cancer in a large type 2 AIP cohort with long follow‐up.Methods: Patients with definitive or probable diagnosis of type 2 AIP by International Consensus Diagnostic Criteria (ICDC) present in our prospectively maintained database since 1995 at 31.12.2021 were identified. All patients were clinically evaluated during the year 2022. Clinical, radiological, serological, and pathological data were evaluated.Results: Eighty‐eight out of 420 patients present in the database (21%) were diagnosed with type 2 AIP (mean age 33.5 ± 13.5 years). According to the ICDC, 21 patients (23.8%) had a definitive and 67 (76.2%) a probable diagnosis of type 2 AIP. The mean follow‐up was 9.2 ± 7.1 years (range 1–27 years). No differences were observed when comparing patients with definitive and probable type 2 AIP diagnosis. Concomitant IBD was reported in 77 patients (87.5%). The probability of disease relapse was lower in patients treated with steroids versus surgery (at 5 years 13% vs. 33%; p = 0.038) but this difference was not statistically significant at multivariable analysis. The risk of endocrine or severe exocrine insufficiency was low (5% and 25%). Four extra‐pancreatic malignancies (5%) were diagnosed, none pancreatic. One patient died in a car accident.Conclusions: Type 2 AIP has benign long‐term clinical outcomes. Mortality and cancer rates are low and no specific follow‐up is needed after radiological remission.
A small tumor size may impact the diagnostic performance of endoscopic ultrasound-guided tissue acquisition (EUS-TA) for diagnosing solid pancreatic lesions (SPLs). We aimed to compare the diagnostic yield of EUS-guided fine-needle aspiration (FNA) and biopsy (FNB) in SPLs with a diameter ≤ 15 mm. Consecutive patients who underwent EUS-TA for SPLs ≤ 15 mm between January 2015 and December 2022 in a tertiary referral center were retrospectively evaluated. The primary endpoint was diagnostic accuracy. The final diagnosis was based on surgical pathology or disease evolution after a minimum follow-up of 6 months. Inadequate samples were all considered false negatives for the study. Secondary outcomes included sample adequacy, factors impacting accuracy, and safety. We included 368 patients (52.4% male; mean age: 60.2 years) who underwent FNA in 72 cases and FNB in 296. The mean size of SPLs was 11.9 ± 2.6 mm. More than three passes were performed in 5.7% and 61.5% of patients in the FNB and FNA groups, respectively (p < 0.0001). FNB outperformed FNA in terms of diagnostic accuracy (89.8% vs. 79.1%, p = 0.013) and sample adequacy (95.9% vs. 86.1%, p < 0.001). On multivariate analysis, using FNA (OR: 2.10, 95% CI: 1.07–4.48) and a final diagnosis (OR: 3.56, 95% CI: 1.82–6.94) of benign conditions negatively impacted accuracy. Overall, the adverse event rate was 0.8%, including one pancreatitis in the FNA group and one pancreatitis and one bleeding in the FNB group, all mild and conservatively managed. EUS-TA for SPLs ≤ 15 mm has a high diagnostic yield and safety. This study suggests the superiority of FNB over FNA, with better performance even with fewer passes performed.