Unai Ayala

Unai Ayala


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 July 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CFCarlos Figuera
Carlos Figuera
UIUnai Irusta
Unai Irusta
EMEduardo Morgado
Eduardo Morgado
EAElisabete Aramendi
Elisabete Aramendi
UAUnai Ayala
Unai Ayala
FAFelipe Alonso-Atienza
Felipe Alonso-Atienza
Early recognition of ventricular fibrillation (VF) and electrical therapy are key for the survival of out-of-hospital cardiac arrest (OHCA) patients treated with automated external defibrillators (AED). AED algorithms for VF-detection are customarily assessed using Holter recordings from public electrocardiogram (ECG) databases, which may be different from the ECG seen during OHCA events. This study evaluates VF-detection using data from both OHCA patients and public Holter recordings. ECG-segments of 4-s and 8-s duration were analyzed. For each segment 30 features were computed and fed to state of the art machine learning (ML) algorithms. ML-algorithms with built-in feature selection capabilities were used to determine the optimal feature subsets for both databases. Patient-wise bootstrap techniques were used to evaluate algorithm performance in terms of sensitivity (Se), specificity (Sp) and balanced error rate (BER). Performance was significantly better for public data with a mean Se of 96.6%, Sp of 98.8% and BER 2.2% compared to a mean Se of 94.7%, Sp of 96.5% and BER 4.4% for OHCA data. OHCA data required two times more features than the data from public databases for an accurate detection (6 vs 3). No significant differences in performance were found for different segment lengths, the BER differences were below 0.5-points in all cases. Our results show that VF-detection is more challenging for OHCA data than for data from public databases, and that accurate VF-detection is possible with segments as short as 4-s.

20 May 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
APArtzai Picon
Artzai Picon
UIUnai Irusta
Unai Irusta
AÁAitor Álvarez-Gila
Aitor Álvarez-Gila
EAElisabete Aramendi
Elisabete Aramendi
FAFelipe Alonso-Atienza
Felipe Alonso-Atienza
TETrygve Eftestøl
Trygve Eftestøl
Early defibrillation by an automated external defibrillator (AED) is key for the survival of out-of-hospital cardiac arrest (OHCA) patients. ECG feature extraction and machine learning have been successfully used to detect ventricular fibrillation (VF) in AED shock decision algorithms. Recently, deep learning architectures based on 1D Convolutional Neural Networks (CNN) have been proposed for this task. This study introduces a deep learning architecture based on 1D-CNN layers and a Long Short-Term Memory (LSTM) network for the detection of VF. Two datasets were used, one from public repositories of Holter recordings captured at the onset of the arrhythmia, and a second from OHCA patients obtained minutes after the onset of the arrest. Data was partitioned patient-wise into training (80%) to design the classifiers, and test (20%) to report the results. The proposed architecture was compared to 1D-CNN only deep learners, and to a classical approach based on VF-detection features and a support vector machine (SVM) classifier. The algorithms were evaluated in terms of balanced accuracy (BAC), the unweighted mean of the sensitivity (Se) and specificity (Sp). The BAC, Se, and Sp of the architecture for 4-s ECG segments was 99.3%, 99.7%, and 98.9% for the public data, and 98.0%, 99.2%, and 96.7% for OHCA data. The proposed architecture outperformed all other classifiers by at least 0.3-points in BAC in the public data, and by 2.2-points in the OHCA data. The architecture met the 95% Sp and 90% Se requirements of the American Heart Association in both datasets for segment lengths as short as 3-s. This is, to the best of our knowledge, the most accurate VF detection algorithm to date, especially on OHCA data, and it would enable an accurate shock no shock diagnosis in a very short time.

1 July 2014 in Resuscitation
Verified
Journal Article
Closed access
UAUnai Ayala
Unai Ayala
TET. Eftestøl
T. Eftestøl
EAErik Alonso
Erik Alonso
UIUnai Irusta
Unai Irusta
EAElisabete Aramendi
Elisabete Aramendi
JKJ. Kramer-Johansen
J. Kramer-Johansen

1 March 2015 in Resuscitation
Verified
Journal Article
Closed access
EAErik Alonso
Erik Alonso
JRJesús Ruiz
Jesús Ruiz
EAElisabete Aramendi
Elisabete Aramendi
DGDigna González-Otero
Digna González-Otero
SGSofía Ruiz de Gauna
Sofía Ruiz de Gauna
MDMohamud Daya
Mohamud Daya

1 January 2014 in BioMed Research International
Verified
Journal Article
Open access
PDF file
UAUnai Ayala
Unai Ayala
UIUnai Irusta
Unai Irusta
JRJ. Ruiz
J. Ruiz
TET. Eftestøl
T. Eftestøl
JKJ. Kramer-Johansen
J. Kramer-Johansen
DGD. González-Otero
D. González-Otero
Interruptions in cardiopulmonary resuscitation (CPR) compromise defibrillation success. However, CPR must be interrupted to analyze the rhythm because although current methods for rhythm analysis during CPR have high sensitivity for shockable rhythms, the specificity for nonshockable rhythms is still too low. This paper introduces a new approach to rhythm analysis during CPR that combines two strategies: a state-of-the-art CPR artifact suppression filter and a shock advice algorithm (SAA) designed to optimally classify the filtered signal. Emphasis is on designing an algorithm with high specificity. The SAA includes a detector for low electrical activity rhythms to increase the specificity, and a shock/no-shock decision algorithm based on a support vector machine classifier using slope and frequency features. For this study, 1185 shockable and 6482 nonshockable 9-s segments corrupted by CPR artifacts were obtained from 247 patients suffering out-of-hospital cardiac arrest. The segments were split into a training and a test set. For the test set, the sensitivity and specificity for rhythm analysis during CPR were 91.0% and 96.6%, respectively. This new approach shows an important increase in specificity without compromising the sensitivity when compared to previous studies.

1 January 2014 in BioMed Research International
Verified
Journal Article
Open access
PDF file
SGSofia Ruiz de Gauna
Sofia Ruiz de Gauna
UIUnai Irusta
Unai Irusta
JRJesus Ruiz
Jesus Ruiz
UAUnai Ayala
Unai Ayala
EAElisabete Aramendi
Elisabete Aramendi
TETrygve Eftestøl
Trygve Eftestøl
Survival from out-of-hospital cardiac arrest depends largely on two factors: early cardiopulmonary resuscitation (CPR) and early defibrillation. CPR must be interrupted for a reliable automated rhythm analysis because chest compressions induce artifacts in the ECG. Unfortunately, interrupting CPR adversely affects survival. In the last twenty years, research has been focused on designing methods for analysis of ECG during chest compressions. Most approaches are based either on adaptive filters to remove the CPR artifact or on robust algorithms which directly diagnose the corrupted ECG. In general, all the methods report low specificity values when tested on short ECG segments, but how to evaluate the real impact on CPR delivery of continuous rhythm analysis during CPR is still unknown. Recently, researchers have proposed a new methodology to measure this impact. Moreover, new strategies for fast rhythm analysis during ventilation pauses or high-specificity algorithms have been reported. Our objective is to present a thorough review of the field as the starting point for these late developments and to underline the open questions and future lines of research to be explored in the following years.