We evaluated the adhesion, friction characteristics, durability against bodily acids, sterilization, cleaning, and anti-reflection performance of diamond-like carbon (DLC) coatings formed as a surface treatment of intracorporeal medical devices. The major coefficients of friction during intubation in a living body in all environments were lower with DLC coatings than with black chrome plating. DLC demonstrated an adhesion of approximately 24 N, which is eight times stronger than that of black chrome plating. DLC-coated samples also showed significant stability without being damaged during acid immersion and high-pressure steam sterilization, as suggested by the results of durability tests. In addition, the coatings remained unpeeled in a usage environment, and there was no change in the anti-reflection performance of the DLC coatings. In summary, DLC coatings are useful for improving intracorporeal device surfaces and extending the lives of medical devices.
Optical classification methods that distinguish amorphous carbon films into six types based on refractive index and extinction coefficient have garnered increasing attention. In this study, five types of amorphous carbon films were prepared on Si substrates using different plasma processes, including physical and chemical vapor deposition. The refractive index and extinction coefficient of the amorphous carbon films were measured using spectroscopic ellipsometry, and the samples were classified into five amorphous carbon types—amorphous, hydrogenated amorphous, tetrahedral amorphous, polymer-like, and graphite-like carbon—based on optical constants. Each amorphous carbon type was irradiated with 253.7 nm UV treatment; the structure and surface properties of each were investigated before and after UV treatment. No significant changes were observed in film structure nor surface oxidation after UV sterilization progressed at approximately the same level for all amorphous carbon types. Osteoblast proliferation associated with amorphous carbon types was evaluated in vitro. Graphite-like carbon, which has relatively high surface oxidation levels, was associated with higher osteoblast proliferation levels than the other carbon types. Our findings inform the selection of suitable amorphous carbon types based on optical constants for use in specific medical devices related to osteoblasts, such as artificial joints and dental implants.
In this study, correlation of cell proliferation with surface properties of the polymer-like carbon (PLC) films of different thicknesses prepared by radio-frequency plasma CVD are investigated. Four PLC samples were prepared via radio frequency plasma chemical vapor deposition on Si substrates. Each PLC film was analyzed using spectroscopic ellipsometry to determine its thickness, refractive index (n), and extinction coefficient (k); the thickness ranged from 29.0 to 356.5 nm. Based on their n–k plots, all the samples were classified as PLC-type films. The biological response of the PLC films was evaluated in vitro using a cell culture. The samples with relatively thick PLC films (>300 nm) exhibited stronger cell proliferation properties than those with thinner films. Moreover, the results of the surface analysis showed no significant differences in the surface composition of those PLC samples, as analyzed using X-ray photoelectron spectroscopy, but that as the PLC films became thicker, their surfaces became rougher on the nanoscale and their wettability improved. Overall, this study showed that careful control of the film growth of PLC films, which affects their surface properties, is essential for their use in bio-interface applications.
In the deposition of polymer-like carbon (PLC) films on Si substrates via radio-frequency plasma CVD (RF-PCVD), the effect of the Ar/CH4 gas mixture ratio on the bio-interface of the PLC films remains unclear and the effectiveness of introducing Ar gas must be proven. In this study, five types of PLC films are prepared on Si substrates via RF-PCVD with an Ar/CH4 gas mixture. The effects of the Ar/CH4 gas ratio on the structure, surface properties, and osteoblast proliferation of the PLC films are investigated. The PLC film structure is graphitized as the hydrogen content in the PLC film decreases with the increasing Ar gas ratio. Based on in vitro cell culture tests, a PLC film with a higher Ar gas ratio promotes the osteoblast proliferative potential after 72 h compared with a PLC film with a relatively low Ar gas ratio. Moreover, the surface roughness and hydrophilicity of the PLC film increase with the Ar gas ratio. Accordingly, we demonstrate the effectiveness of Ar gas incorporation into the RF-PCVD process to promote the biological responsiveness of PLC films. PLC coatings are expected to be widely applied for surface modification to improve the mechanical characteristics and biological responses of orthopedic implant devices.