Mohammad Ali Khayamian

Dr. Mohammad Ali Khayamian


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2017 in Nature Communications
Verified
Journal Article
Open access
PDF file
MNMohammad Saeid Nikshoar
Mohammad Saeid Nikshoar
MKMohammad Ali Khayamian
Mohammad Ali Khayamian
SASaeid Ansaryan
Saeid Ansaryan
HSHassan Sanati
Hassan Sanati
MGMilad Gharooni
Milad Gharooni
MAMohammad Abdolahad
Mohammad Abdolahad
Detecting the micrometastasis is a major challenge in patients’ survival. The small volume of the biopsied tissue results in limited number of histopathological samples and might reduce the rate of accurate diagnosis even by molecular technologies. We introduce a microelectronic biochip (named Metas-Chip) to detect the micrometastasis in unprocessed liquid or solid samples. It works based on the tendency of malignant cells to track single human umbilical vein endothelial cell (HUVEC)-sensing traps. Such cells detach themselves from the biopsied sample and invade the sensing traps by inducing membrane retraction and blebbing, which result in sharp changes in electrical response of the sensing elements. Metas-Chip identified the metastasis in more than 70 breast cancer patients, in less than 5 h. Moreover it detected the metastasis in lymph nodes of nine patients whom were missed by conventional pathological procedure. Multilevel IHC and real-time polymerase chain reaction (RT-PCR) tests confirmed the diagnosis.

6 May 2023 in Nano Energy
Verified
Journal Article
Closed access
MKMohammad Ali Khayamian
Mohammad Ali Khayamian
HAHamed Abadijoo
Hamed Abadijoo
SSShahriar Shalileh
Shahriar Shalileh
MGMohammadreza Ghaderinia
Mohammadreza Ghaderinia
HSHossein Simaee
Hossein Simaee
MAMohammad Abdolahad
Mohammad Abdolahad

2 December 2023 in Nano Energy
Verified
Journal Article
Closed access
HAHamed Abadijoo
Hamed Abadijoo
RSReyhaneh Shakibi
Reyhaneh Shakibi
FPFarshid Rostami Pouria
Farshid Rostami Pouria
NMNavid Manoochehri
Navid Manoochehri
SMShima Moharamipour
Shima Moharamipour
MKMohammad Ali Khayamian
Mohammad Ali Khayamian

25 October 2021 in RSC Advances
Verified
Journal Article
Open access
PDF file
MKMohammad Ali Khayamian
Mohammad Ali Khayamian
Mohammad Salemizadeh PariziMohammad Salemizadeh Parizi
Mohammad Salemizadeh Parizi
MGMohammadreza Ghaderinia
Mohammadreza Ghaderinia
HAHamed Abadijoo
Hamed Abadijoo
SVShohreh Vanaei
Shohreh Vanaei
MAMohammad Abdolahad
Mohammad Abdolahad
Concurrent with the pandemic announcement of SARS-CoV-2 infection by the WHO, a variety of reports were published confirming the cytokine storm as the most mortal effect of the virus on the infected patients. Hence, cytokine storm as an evidenced consequence in most of the COVID-19 patients could offer a promising opportunity to use blood as a disease progression marker. Here, we have developed a rapid electrochemical impedance spectroscopy (EIS) sensor for quantifying the overall immune activity of the patients. Since during the cytokine storm many types of cytokines are elevated in the blood, there is no need for specific detection of a single type of cytokine and the collective behavior is just measured without any electrode functionalization. The sensor includes a monolayer graphene on a copper substrate as the working electrode (WE) which is able to distinguish between the early and severe stage of the infected patients. The charge transfer resistance (RCT) in the moderate and severe cases varies about 65% and 138% compared to the normal groups, respectively and a specificity of 77% and sensitivity of 100% based on ELISA results were achieved. The outcomes demonstrate a significant correlation between the total mass of the three main hypercytokinemia associated cytokines including IL-6, TNF-α and IFN-γ in patients and the RCT values. As an extra application, the biosensor's capability for diagnosis of COVID-19 patients was tested and a sensitivity of 92% and specificity of 50% were obtained compared to the RT-PCR results.

1 March 2018 in Ultrasonics Sonochemistry
Verified
Journal Article
Closed access
MKMohammad Ali Khayamian
Mohammad Ali Khayamian
MBMajid Baniassadi
Majid Baniassadi
MAMohammad Abdolahad
Mohammad Abdolahad

1 January 2019 in Drug Delivery
Verified
Journal Article
Open access
MKMohammad Ali Khayamian
Mohammad Ali Khayamian
SSShahriar Shalileh
Shahriar Shalileh
SVShohreh Vanaei
Shohreh Vanaei
Mohammad Salemizadeh PariziMohammad Salemizadeh Parizi
Mohammad Salemizadeh Parizi
SASaeid Ansaryan
Saeid Ansaryan
MAMohammad Abdolahad
Mohammad Abdolahad
Artificial cavitation as a prerequisite of sonoporation, plays an important role on the ultrasound (US) assisted drug delivery systems. In this study, we have proposed a new method of microbubble (MB) generation by local electrolysis of the medium. An integrated interdigital array of three-electrode system was designed and patterned on a nickel-coated quartz substrate and then, a short DC electrical pulse was applied that consequently resulted in distributed generation of microbubbles at the periphery of the electrodes. Growth of the carbon nanotube (CNT) nanostructures on the surface of the electrodes approximately increased the number of generated microbubbles up to 7-fold and decreased their average size from ∼20 µm for bare to ∼7 µm for CNT electrodes. After optimizing the three-electrode system, biocompatibility assays of the CNT electrodes stimulated by DC electrical micropulses were conducted. Finally, the effect of the proposed method on the sonoporation efficiency and drug uptake of breast cells were assessed using cell cycle and Annexin V/PI flow cytometry analysis. These results show the potential of electrochemical generation of MBs by CNT electrodes as an easy, available and promising technique for artificial cavitation and ultrasound assisted drug delivery.