Emilie Bédard

Dr. Emilie Bédard

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2015 in Water Research
Verified
Journal Article
Closed access
EBEmilie Bédard
Emilie Bédard
SFStéphanie Fey
Stéphanie Fey
DCDominique Charron
Dominique Charron
CLCindy Lalancette
Cindy Lalancette
PCPhilippe Cantin
Philippe Cantin
MPMichèle Prévost
Michèle Prévost

21 June 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
EBEmilie Bédard
Emilie Bédard
CLCéline Laferrière
Céline Laferrière
EDEric Déziel
Eric Déziel
MPMichèle Prévost
Michèle Prévost
Microbial drinking water quality can be altered in large buildings, especially after stagnation. In this study, bacterial profiles were generated according to the stagnation time and the volume of water collected at the tap. Successive volumes of cold and hot water were sampled after controlled stagnation periods. Bacterial profiles revealed an important decline (> 2 log) in culturable cells in the first 500 mL sampled from the hot and cold water systems, with a steep decline in the first 15 mL. The strong exponential correlation (R2 ≥ 0.97) between the culturable cell counts in water and the pipe surface-to-volume ratio suggests the biofilm as the main contributor to the rapid increase in suspended culturable cells measured after a short stagnation of one-hour. Results evidence the contribution of the high surface-to-volume ratio at the point of use and the impact of short stagnation times on the increased bacterial load observed. Simple faucets with minimal internal surface area should be preferred to minimize surface area. Sampling protocol, including sampling volume and prior stagnation, was also shown to impact the resulting culturable cell concentration by more than 1000-fold. Sampling a smaller volume on first draw after stagnation will help maximize recovery of bacteria.

9 August 2017 in Pathogens
Verified
Journal Article
Open access
PDF file
CLCindy Lalancette
Cindy Lalancette
DCDominique Charron
Dominique Charron
CLCéline Laferrière
Céline Laferrière
PDPatrick Dolcé
Patrick Dolcé
Eric DézielEric Déziel
Eric Déziel
EBEmilie Bédard
Emilie Bédard
Identifying environmental sources of Pseudomonas aeruginosa (Pa) related to hospital-acquired infections represents a key challenge for public health. Biofilms in water systems offer protection and favorable growth conditions, and are prime reservoirs of microorganisms. A comparative genotyping survey assessing the relationship between Pa strains recovered in hospital sink biofilm and isolated in clinical specimens was conducted. Environmental strains from drain, faucet and sink-surface biofilm were recovered by a culture method after an incubation time ranging from 48 to 240 h. The genotyping of 38 environmental and 32 clinical isolates was performed using a multiple-locus variable-number of tandem repeats analysis (MLVA). More than one-third of Pa isolates were only cultivable following ≥48 h of incubation, and were predominantly from faucet and sink-surface biofilms. In total, 41/70 strains were grouped within eight genotypes (A to H). Genotype B grouped a clinical and an environmental strain isolated in the same ward, 5 months apart, suggesting this genotype could thrive in both contexts. Genotype E grouped environmental isolates that were highly prevalent throughout the hospital and that required a longer incubation time. The results from the multi-hospital follow-up study support the drain as an important reservoir of Pa dissemination to faucets, sink surfaces and patients. Optimizing the recovery of environmental strains will strengthen epidemiological investigations, facilitate pathway identification, and assist in identifying and controlling the reservoirs potentially associated to hospital-acquired infections.

15 April 2016 in Pathogens
Verified
Journal Article
Open access
PDF file
EBEmilie Bédard
Emilie Bédard
IBInès Boppe
Inès Boppe
SKSerge Kouamé
Serge Kouamé
PMPhilippe Martin
Philippe Martin
LPLinda Pinsonneault
Linda Pinsonneault
MPMichele Prevost
Michele Prevost
Following nosocomial cases of Legionella pneumophila, the investigation of a hot water system revealed that 81.5% of sampled taps were positive for L. pneumophila, despite the presence of protective levels of copper in the water. A significant reduction of L. pneumophila counts was observed by culture after heat shock disinfection. The following corrective measures were implemented to control L. pneumophila: increasing the hot water temperature (55 to 60 °C), flushing taps weekly with hot water, removing excess lengths of piping and maintaining a water temperature of 55 °C throughout the system. A gradual reduction in L. pneumophila counts was observed using the culture method and qPCR in the 18 months after implementation of the corrective measures. However, low level contamination was retained in areas with hydraulic deficiencies, highlighting the importance of maintaining a good thermal regime at all points within the system to control the population of L. pneumophila.

26 June 2014 in FEMS Microbiology Letters
Verified
Journal Article
Open access
PDF file
EBEmilie Bédard
Emilie Bédard
DCDominique Charron
Dominique Charron
CLCindy Lalancette
Cindy Lalancette
Eric DézielEric Déziel
Eric Déziel
MPMichèle Prévost
Michèle Prévost
The authors investigated the loss of culturability of Pseudomonas aeruginosa in presence of copper and chlorine concentrations typically found in drinking water

20 July 2015 in Infection Control & Hospital Epidemiology
Verified
Journal Article
Closed access
PDF file
EBEmilie Bédard
Emilie Bédard
CLCéline Laferrière
Céline Laferrière
DCDominique Charron
Dominique Charron
CLCindy Lalancette
Cindy Lalancette
CRChristian Renaud
Christian Renaud
MPMichèle Prévost
Michèle Prévost
OBJECTIVE: To perform a post-outbreak prospective study of the Pseudomonas aeruginosa contamination at the faucets (water, aerator and drain) by culture and quantitative polymerase chain reaction (qPCR) and to assess environmental factors influencing occurrenceSETTING: A 450-bed pediatric university hospital in Montreal, CanadaMETHODS: Water, aerator swab, and drain swab samples were collected from faucets and analyzed by culture and qPCR for the post-outbreak investigation. Water microbial and physicochemical parameters were measured, and a detailed characterization of the sink environmental and design parameters was performed.RESULTS: The outbreak genotyping investigation identified drains and aerators as the source of infection. The implementation of corrective measures was effective, but post-outbreak sampling using qPCR revealed 50% positivity for P. aeruginosa remaining in the water compared with 7% by culture. P. aeruginosa was recovered in the water, the aerator, and the drain in 21% of sinks. Drain alignment vs the faucet and water microbial quality were significant factors associated with water positivity, whereas P. aeruginosa load in the water was an average of 2 log higher for faucets with a positive aerator.CONCLUSIONS: P. aeruginosa contamination in various components of sink environments was still detected several years after the resolution of an outbreak in a pediatric university hospital. Although contamination is often not detectable in water samples by culture, P. aeruginosa is present and can recover its culturability under favorable conditions. The importance of having clear maintenance protocols for water systems, including the drainage components, is highlighted.Infect. Control Hosp. Epidemiol. 2015;36(11):1283–1291