Takushi Kawamorita

Dr. Takushi Kawamorita


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2011 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
TKTakushi Kawamorita
Takushi Kawamorita
HUHiroshi Uozato
Hiroshi Uozato
KSKimiya Shimizu
Kimiya Shimizu

1 April 2010 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
TKTakushi Kawamorita
Takushi Kawamorita
HUHiroshi Uozato
Hiroshi Uozato
KKKazutaka Kamiya
Kazutaka Kamiya
KSKimiya Shimizu
Kimiya Shimizu
To evaluate the relationship between the horizontal ciliary sulcus diameter and anterior chamber diameter measured by 35 MHz ultrasound biomicroscopy (UBM) and the horizontal corneal diameter (white to white [WTW]) measured by scanning-slit topography and to assess the repeatability (intraexaminer difference) of the 2 methods. Department of Orthoptics and Visual Science, Kitasato University School, Sagamihara, Japan. The repeatability and agreement of UBM and scanning-slit topography were assessed using the intraclass correlation (ICC) and the Bland and Altman method (ie, mean difference and 95% limits of agreement [LoA]). Thirty-one normal eyes of 31 subjects (mean age 22.6 years +/- 4.8 [SD]) were evaluated. The mean differences between the repeated measurements were as follows: ciliary sulcus diameter, -0.05 mm (95% LoA, -0.38 to 0.28 mm); anterior chamber diameter, 0.02 mm (95% LoA, -0.42 to 0.45 mm); and WTW diameter, -0.02 mm (95% LoA, -0.18 to 0.13 mm). The agreement between ciliary sulcus diameter and WTW diameter was poor (ICC, 0.679). The mean difference was 0.41 mm (95% LoA, -0.46 to 1.28 mm). The agreement between the ciliary sulcus diameter and anterior chamber diameter was high (ICC, 0.918). The mean difference was 0.13 mm (95% LoA, -0.41 to 0.67 mm). Results suggest that direct measurement of the ciliary sulcus by UBM would reduce the percentage of complications related to intraocular lens sizing over the percentage when sizing is based on WTW diameter.

19 February 2016 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
TKTakushi Kawamorita
Takushi Kawamorita
KSKimiya Shimizu
Kimiya Shimizu
NSNobuyuki Shoji
Nobuyuki Shoji

20 January 2017 in Eye
Verified
Journal Article
Open access
PDF file
TKTakushi Kawamorita
Takushi Kawamorita
KSK Shimizu
K Shimizu
NSN Shoji
N Shoji
Purpose Although one of the advantages of the Hole-ICL implantation is that laser iridotomy (LI) is unnecessary, the evidence have not been reported from the viewpoint of aqueous humor circulation. We investigated the effect of laser iridotomy (LI) on the fluid dynamics of aqueous humor in an implantable collamer lens (ICL) with a central hole, that is, a Hole-ICL using computational fluid dynamics. Methods A fluid dynamics simulation was performed using the thermal-hydraulic analysis software FloEFD (Mentor Graphics Corp.). For the simulation, three-dimensional eye models with a conventional ICL (Model ICM, STAAR SURGICAL) and a Hole-ICL were used. The LI diameters were 250 and 500 μm. The flow distribution between the anterior surface of the crystalline lens and the posterior surface of the ICL was also calculated. Results The flow velocity 0.25 mm in front of the center of the crystalline lens in the Hole-ICL without LI, with LI of 250 μm, and with LI of 500 μm was 1.48 × 10−1, 1.20 × 10−1, and 4.52 × 10−2 mm/s, respectively. The flow velocity in the conventional ICL without LI, with LI of 250 μm, and with LI of 500 μm was 1.21 × 10−5, 3.60 × 10−4, and 6.33 × 10−4 mm/s, respectively. Conclusions These results suggest that there is less need for LI in a posterior chamber phakic intraocular lens with a central hole from the viewpoint of aqueous humor circulation, although the results can be considered only in an ideal condition and further studies are needed to clarify the effect of LI in clinical practice.

1 May 2010 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
TKTakushi Kawamorita
Takushi Kawamorita
HUHiroshi Uozato
Hiroshi Uozato
THTomoya Handa
Tomoya Handa
MIMisae Ito
Misae Ito
KSKimiya Shimizu
Kimiya Shimizu
Reports Takushi Kawamorita, CO, PhD; Hiroshi Uozato, PhD; Tomoya Handa, CO, PhD; Misae Ito, CO, MSc; Kimiya Shimizu, MD, PhD To investigate the effect of pupil size on visual acuity in pseudophakic monovision. For the simulation, a modified Liou-Brennan model eye was used. The model eye was designed to include a centered optical system, corneal asphericity, an iris pupil, a Stiles–Crawford effect, an intraocular lens, and chromatic aberration. Calculation of the modulation transfer function (MTF) was performed with ZEMAX software. Visual acuity was estimated from the MTF and the retinal threshold curve. The sizes of the entrance pupil were 2.0, 2.5, 3.0, and 4.0 mm. Decreasing pupil diameter and increasing myopia progressively improved near visual acuity. For an entrance pupil size of 2.5 mm and a refractive error of −1.50 diopters, the logMAR value (Snellen; metric) in the non-dominant eye at 40 cm was 0.06 (20/23; 6/6.9). Knowledge of the patient’s pupil diameter at near fixation can assist surgeons in determining the optimum degree of myopia for successful monovision. From the Department of Orthoptics and Visual Science, Kitasato University School of Allied Health Sciences (Kawamorita, Uozato, Handa, Ito); the Department of Ophthalmology and Visual Science, Kitasato University Graduate School of Medical Sciences (Kawamorita, Uozato, Handa, Shimizu); and the Department of Ophthalmology, Kitasato University School of Medicine (Shimizu), Sagamihara, Japan. Supported in part by a grant from Kitasato University School of Allied Health Sciences (Grant-in-Aid for Research Project, No. 2009–6558) (Kawamorita) and Kitasato University Research Grant for Young Researchers (No. 2009–4012) (Kawamorita). The authors have no proprietary interest in the materials presented herein. Correspondence: Takushi Kawamorita, CO, PhD, Dept of Orthoptics and Visual Science, Kitasato University School of Allied Health Sciences, 1-15-1 Kitasato, Sagamihara, 228-8555, Japan. Tel: 81 42 778 9669; Fax: 81 42 778 9684; E-mail: kawa2008@kitasato-u.ac.jp 10.3928/1081597X-20100212-01 Healio is intended for health care provider use and all comments will be posted at the discretion of the editors. We reserve the right not to post any comments with unsolicited information about medical devices or other products. At no time will Healio be used for medical advice to patients.

1 January 2015 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
YTYoriko Takahashi
Yoriko Takahashi
TKTakushi Kawamorita
Takushi Kawamorita
NMNorihiro Mita
Norihiro Mita
NHNatsuko Hatsusaka
Natsuko Hatsusaka
SSShinsuke Shibata
Shinsuke Shibata
HSHiroshi Sasaki
Hiroshi Sasaki
To determine whether subsurface nanoglistening in hydrophobic acrylic intraocular lenses (IOL) diminishes visual performance. Department of Ophthalmology, Kanazawa Medical University, Uchinada, Ishikawa, Japan. Experimental study. The effect of subsurface nanoglistenings was simulated using optical design software Lighttools and Code V with the Liou-Brenann model eye and an acrylic IOL. Peak irradiance of the retina, forward light scattering, and modulation transfer function (MTF) were evaluated. During optical simulation, particle diameters were set at 100 nm, 150 nm, and 200 nm and volume ratios at 0%, 0.05%, 0.1%, 0.2%, 0.5%, and 1.0%. Peak irradiance decreased as subsurface nanoglistening volume ratio and particle size increased. At a volume ratio of 0.05%, the peak irradiance of subsurface nanoglistening particles 100 nm, 150 nm, and 200 nm in diameter decreased 0.7%, 1.8%, and 2.9%, respectively, compared with those at volume ratio 0% (no subsurface nanoglistenings). At a volume ratio of 0.1%, the peak irradiance of subsurface nanoglistening particles 100 nm, 150 nm, and 200 nm decreased 1.5%, 3.6%, and 5.7%, respectively. Forward light scattering increased with increased size of subsurface nanoglistening particle and volume ratio. The MTF was not altered by changes in subsurface nanoglistening particle size or volume ratio. Subsurface nanoglistenings increased forward scattering slightly and reduced irradiance but significantly diminished retinal image. The effect of subsurface nanoglistenings on visual function in the absence of severe retinal disease was minimal. No author has a financial or proprietary interest in any material or method mentioned.