Donato Squillaci

Dr. Donato Squillaci

Università degli Studi di Firenze - Dipartimento di Medicina Sperimentale e Clinica
+1
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Journal of Analytical Methods in Chemistry
Verified
Journal Article
Open access
PDF file
Stefano DugheriStefano Dugheri
Stefano Dugheri
Nicola MucciNicola Mucci
Nicola Mucci
GCGiovanni Cappelli
Giovanni Cappelli
LTLucia Trevisani
Lucia Trevisani
ABAlessandro Bonari
Alessandro Bonari
Giulio ArcangeliGiulio Arcangeli
Giulio Arcangeli
The solid‐phase microextraction (SPME), invented by Pawliszyn in 1989, today has a renewed and growing use and interest in the scientific community with fourteen techniques currently available on the market. The miniaturization of traditional sample preparation devices fulfills the new request of an environmental friendly analytical chemistry. The recent upswing of these solid‐phase microextraction technologies has brought new availability and range of robotic automation. The microextraction solutions propose today on the market can cover a wide variety of analytical fields and applications. This review reports on the state‐of‐the‐art innovative solid‐phase microextraction techniques, especially those used for chromatographic separation and mass‐spectrometric detection, given the recent improvements in availability and range of automation techniques. The progressively implemented solid‐phase microextraction techniques and related automated commercially available devices are classified and described to offer a valuable tool to summarize their potential combinations to face all the laboratories requirements in terms of analytical applications, robustness, sensitivity, and throughput.

20 April 2022 in Safety
Verified
Journal Article
Open access
PDF file
Stefano DugheriStefano Dugheri
Stefano Dugheri
GCGiovanni Cappelli
Giovanni Cappelli
LTLucia Trevisani
Lucia Trevisani
SKSimon Kemble
Simon Kemble
FPFabrizio Paone
Fabrizio Paone
Giulio ArcangeliGiulio Arcangeli
Giulio Arcangeli
Metal-additive manufacturing (AM), particularly the powder-bed fusion (PBF) technique, is undergoing a transition from the short-run production of components to higher-volume manufacturing. The industry’s increased production efficiency is paired with a growing awareness of the risks related to the inhalation of very fine metal powders during PBF and AM processes, and there is a pressing need for a ready-to-use approach to assess the risks and the occupational exposure to these very final metal powders. This article presents a study conducted in an AM facility, which was conducted with the aim to propose a solution to monitor incidental airborne particle emissions during metal AM by setting up an analytical network for a tailored approach to risk assessment. Quantitative data about the respirable and inhalable particle and metal content were obtained by gravimetric and ICP-MS analyses. In addition, the concentrations of airborne particles (10–300 nm) were investigated using a direct reading instrument. A qualitative approach for risk assessment was fulfilled using control banding Nanotool v2.0. The results show that the operations in the AM facility are in line with exposure limit levels for both micron-sized and nano-sized particles. The particulate observed in the working area contains metals, such as chromium, cobalt, and nickel; thus, biological monitoring is recommended. To manage the risk level observed for all of the tasks during the AM process, containment and the supervision of an occupational safety expert are recommended to manage the risk. This study represents a useful tool that can be used to carry out a static evaluation of the risk and exposure to potentially harmful very fine metal powders in AM; however, due to the continuous innovations in this field, a dynamic approach could represent an interesting future perspective for occupational safety.

16 July 2023 in Molecules
Verified
Journal Article
Open access
PDF file
Stefano DugheriStefano Dugheri
Stefano Dugheri
GCGiovanni Cappelli
Giovanni Cappelli
NFNiccolò Fanfani
Niccolò Fanfani
JCJacopo Ceccarelli
Jacopo Ceccarelli
Giorgio MarrubiniGiorgio Marrubini
Giorgio Marrubini
Giulio ArcangeliGiulio Arcangeli
Giulio Arcangeli
Formaldehyde (FA) is a toxic compound and a human carcinogen. Regulating FA-releasing substances in commercial goods is a growing and interesting topic: worldwide production sectors, like food industries, textiles, wood manufacture, and cosmetics, are involved. Thus, there is a need for sensitive, economical, and specific FA monitoring tools. Solid-phase microextraction (SPME), with O-(2,3,4,5,6-pentafluorobenzyl)-hydroxylamine (PFBHA) on-sample derivatization and gas chromatography, is proposed for FA monitoring of real-life samples. This study reports the use of polydimethylsiloxane (PDMS) as a sorbent phase combined with innovative commercial methods, such as multiple SPME (MSPME) and cooling-assisted SPME, for FA determination. Critical steps, such as extraction and sampling, were evaluated in method development. The derivatization was performed at 60 °C for 30 min, followed by 15 min sampling at 10 °C, in three cycles (SPME Arrow) or six cycles (SPME). The sensitivity was satisfactory for the method’s purposes (LOD-LOQ at 11-36 ng L−1, and 8-26 ng L−1, for SPME and SPME Arrow, respectively). The method’s linearity ranges from the lower LOQ at trace level (ng L−1) to the upper LOQ at 40 mg L−1. The precision range was 5.7–10.2% and 4.8–9.6% and the accuracy was 97.4% and 96.3% for SPME and SPME Arrow, respectively. The cooling MSPME set-up applied to real commercial goods provided results of quality comparable to previously published data.

18 October 2024 in Molecules
Verified
Journal Article
Open access
PDF file
Stefano DugheriStefano Dugheri
Stefano Dugheri
GCGiovanni Cappelli
Giovanni Cappelli
NFNiccolò Fanfani
Niccolò Fanfani
Donato SquillaciDonato Squillaci
Donato Squillaci
IRIlaria Rapi
Ilaria Rapi
Nicola MucciNicola Mucci
Nicola Mucci
MonoTrapTM was introduced in 2009 as a novel miniaturized configuration for sorptive sampling. The method for the characterization of volatile organic compound (VOC) emission profiles from hot mix asphalt (HMA) consisted of a two-step procedure: the analytes, initially adsorbed into the coating in no vacuum- or vacuum-assistance mode, were then analyzed following an automated thermal desorption (TD) step. We took advantage of the theoretical formulation to reach some conclusions on the relationship between the physical characteristics of the monolithic material and uptake rates. A total of 35 odor-active volatile compounds, determined by gas chromatography-mass spectrometry/olfactometry analysis, contributed as key odor compounds for HMA, consisting mainly of aldehydes, alcohols, and ketones. Chemometric analysis revealed that MonoTrapTM RGC18-TD was the better coating in terms of peak area and equilibrium time. A comparison of performance showed that Vac/no-Vac ratios increased, about an order of magnitude, as the boiling point of target analytes increased. The innovative hybrid adsorbent of silica and graphite carbon monolith technology, having a large surface area bonded with octadecylsilane, showed effective adsorption capability, especially to polar compounds.

20 May 2021 in Separations
Verified
Journal Article
Open access
PDF file
Stefano DugheriStefano Dugheri
Stefano Dugheri
Nicola MucciNicola Mucci
Nicola Mucci
Enrico MiniEnrico Mini
Enrico Mini
Donato SquillaciDonato Squillaci
Donato Squillaci
Giorgio MarrubiniGiorgio Marrubini
Giorgio Marrubini
Giulio ArcangeliGiulio Arcangeli
Giulio Arcangeli
Platinum-based antineoplastic drugs (PtADs) are among the most important and used families of chemotherapy drugs, which, even showing severe side effects and being hindered by drug resistance, are not likely to be replaced clinically any time soon. The growing interest in the occupational health community in antineoplastic drug (AD) surface contamination requires the development of increasingly fast and easy high-throughput monitoring methods, even considering the lack of harmonized legally binding regulation criteria. Thus, a wipe sampling method together with zwitterionic hydrophilic interaction liquid chromatography (HILIC-Z)–tandem mass spectrometry (MS/MS) analysis was developed for the simultaneous evaluation of oxaliplatin, cisplatin, and carboplatin surface contaminations. A design of experiments approach was used to optimize the chromatographic conditions. Limits of quantification ranging from 2 to 5 ng/mL were obtained from interday and intraday repetitions for oxaliplatin and carboplatin, and between 170 and 240 ng/mL for cisplatin. The wipe desorption procedure is equivalent to other AD sampling methods, enabling a fast sample preparation, with an LC-MS/MS analysis time of less than 7 min.

10 September 2021 in Separations
Verified
Journal Article
Open access
PDF file
Stefano DugheriStefano Dugheri
Stefano Dugheri
Nicola MucciNicola Mucci
Nicola Mucci
Donato SquillaciDonato Squillaci
Donato Squillaci
Giorgio MarrubiniGiorgio Marrubini
Giorgio Marrubini
GBGianluca Bartolucci
Gianluca Bartolucci
Giulio ArcangeliGiulio Arcangeli
Giulio Arcangeli
Growing attention on carcinogenicity and mutagenicity of antineoplastic drugs (ADs) from the International Agencies has led to the present strict safe handling and administration regulations. Accordingly, one of the most common ways to assess occupational exposure to these substances is to identify and quantify possible surface contamination inside hospital preparation and administration units. Thus, it is essential to develop a fast and high-throughput monitoring method capable of identifying a significant number of ADs. The present study reports developing a UHPLC–MS/MS analysis to screen 26 ADs surface contamination through wipe test sampling. A Cortecs UPLC T3 50 × 2.1 mm (1.6 µm) column was selected to perform the analysis, using the evaluations of previous studies and the Product Quality Research Institute (PQRI) database. The design of experiments (DoE) methodological approach was used to optimize the chromatographic conditions concerning the best separation between all ADs. The limits of quantification for the analytes were between the pg/mL and ng/mL orders, and the turnaround time was limited to about 15 min. The obtained accuracy was mostly between 90% and 110% for all the analytes, while the precision was under 10% and a low matrix effect was observed for said analytes. Only vindesine and docetaxel presented lower performances.