Dominik F. Vollherbst

Dr. Dominik F. Vollherbst

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2025 in New England Journal of Medicine
Verified
Journal Article
Closed access
MGMayank Goyal
Mayank Goyal
JOJohanna M Ospel
Johanna M Ospel
AGAravind Ganesh
Aravind Ganesh
DDDar Dowlatshahi
Dar Dowlatshahi
DVDavid Volders
David Volders
EIESCAPE-MeVO Investigators
ESCAPE-MeVO Investigators
Whether the large effect size of endovascular thrombectomy (EVT) for stroke due to large-vessel occlusion applies to stroke due to medium-vessel occlusion is unclear. In a multicenter, prospective, randomized, open-label trial with blinded outcome evaluation, we assigned patients with acute ischemic stroke due to medium-vessel occlusion who presented within 12 hours from the time that they were last known to be well and who had favorable baseline noninvasive brain imaging to receive EVT plus usual care or usual care alone. The primary outcome was the modified Rankin scale score (range, 0 [no symptoms] to 6 [death]) at 90 days, reported as the percentage of patients with a score of 0 or 1. A total of 530 patients from five countries were enrolled between April 2022 and June 2024, with 255 patients assigned to the EVT group and 275 to the usual-care group. Most patients (84.7%) had primary occlusions in a middle-cerebral-artery branch. A modified Rankin scale score of 0 or 1 at 90 days occurred in 106 of 255 patients (41.6%) in the EVT group and in 118 of 274 (43.1%) in the usual-care group (adjusted rate ratio, 0.95; 95% confidence interval [CI], 0.79 to 1.15; P = 0.61). Mortality at 90 days was 13.3% in the EVT group and 8.4% in the usual-care group (adjusted hazard ratio, 1.82; 95% CI, 1.06 to 3.12). Symptomatic intracranial hemorrhage occurred in 14 of 257 patients (5.4%) in the EVT group and in 6 of 272 (2.2%) in the usual-care group. Endovascular treatment for acute ischemic stroke due to medium-vessel occlusion within 12 hours did not lead to better outcomes at 90 days than usual care. (Funded by the Canadian Institutes for Health Research and Medtronic; ESCAPE-MeVO ClinicalTrials.gov number, NCT05151172.).

29 July 2021 in Clinical Neuroradiology
Verified
Journal Article
Open access
PDF file
DVDominik F. Vollherbst
Dominik F. Vollherbst
RCRené Chapot
René Chapot
MBMartin Bendszus
Martin Bendszus
MMMarkus A. Möhlenbruch
Markus A. Möhlenbruch
Background: Endovascular embolization is an effective treatment option for cerebral arteriovenous malformations (AVMs) and dural arteriovenous fistulas (DAVFs). A variety of liquid embolic agents have been and are currently used for embolization of AVMs and DAVFs. Knowledge of the special properties of the agent which is used is crucial for an effective and safe embolization procedure. Material and Methods: This article describes the properties and indications of the liquid embolic agents which are currently available: cyanoacrylates (also called glues), and the copolymers Onyx, Squid and PHIL, as well as their respective subtypes. Results: Cyanoacrylates were the predominantly used agents in the 1980s and 1990s. They are currently still used in specific situations, for example for the occlusion of macro-shunts, for the pressure cooker technique or in cases in which microcatheters are used that are not compatible with dimethyl-sulfoxide. The first broadly used copolymer-based embolic agent Onyx benefits from a large amount of available experience and data, which demonstrated its safety and efficacy in the treatment of cerebral vascular malformations, while its drawbacks include temporary loss of visibility during longer injections and artifacts in cross-sectional imaging. The more recently introduced agents Squid and PHIL aim to overcome these shortcomings and to improve the success rate of endovascular embolization. Novelties of these newer agents with potential advantages include extra-low viscosity versions, more stable visibility, and a lower degree of imaging artifacts. Conclusion: All the available liquid embolic agents feature specific potential advantages and disadvantages over each other. The choice of the most appropriate embolic agent must be made based on the specific material characteristics of the agent, related to the specific anatomical characteristics of the target pathology.

18 May 2017 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
DVDominik F. Vollherbst
Dominik F. Vollherbst
Christof M SommerChristof M Sommer
Christof M Sommer
CUC. Ulfert
C. Ulfert
JPJohannes Pfaff
Johannes Pfaff
MBM. Bendszus
M. Bendszus
MMMarkus A. Möhlenbruch
Markus A. Möhlenbruch
BACKGROUND AND PURPOSE: Embolization plays a key role in the treatment of arteriovenous malformations. The aim of this study was to evaluate an established (Onyx) and a novel (precipitating hydrophobic injectable liquid [PHIL]) liquid embolic agent in an in vitro AVM model. MATERIALS AND METHODS: An AVM model was integrated into a circuit system. The artificial nidus (subdivided into 28 honeycomb-like sections) was embolized with Onyx 18 (group Onyx; n = 8) or PHIL 25 (group PHIL; n = 8) with different pause times between the injections (30 and 60 seconds, n = 4 per study group) by using a 1.3F microcatheter. Procedure times, number of injections, embolization success (defined as the number of filled sections of the artificial nidus), volume of embolic agent, and frequency and extent of reflux and draining vein embolization were assessed. RESULTS: Embolization success was comparable between Onyx and PHIL. Shorter pause times resulted in a significantly higher embolization success for PHIL (median embolization score, 28 versus 18; P = .011). Compared with Onyx, lower volumes of PHIL were required for the same extent of embolization (median volume per section of the artificial nidus, 15.5 versus 3.6 μL; P < .001). CONCLUSIONS: While the embolization success was comparable for Onyx and PHIL, pause time had a considerable effect on the embolization success in an in vitro AVM model. Compared with Onyx, lower volumes of PHIL were required for the same extent of embolization.

30 March 2023 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
DVDominik F. Vollherbst
Dominik F. Vollherbst
HLH. Lücking
H. Lücking
JDJ. DuPlessis
J. DuPlessis
MSM. Sonnberger
M. Sonnberger
CMC. Maurer
C. Maurer
MMMarkus A. Möhlenbruch
Markus A. Möhlenbruch
BACKGROUND AND PURPOSE: Flow diverters with antithrombotic coatings are increasingly used to improve the safety of flow diverter treatments of intracranial aneurysms. This study aimed to investigate the safety and short-term efficacy of the new FRED X flow diverter. MATERIALS AND METHODS: Medical charts and procedural and imaging data of a consecutive series of patients with intracranial aneurysms who were treated with the FRED X at 9 international neurovascular centers were retrospectively analyzed. RESULTS: One hundred sixty-one patients (77.6% women; mean age, 55 years) with 184 aneurysms (11.2% acutely ruptured) were included in this study. Most aneurysms were located in the anterior circulation (77.0%), most frequently at the ICA (72.7%). The FRED X was successfully implanted in all procedures. Additional coiling was performed in 29.8%. In-stent balloon angioplasty was necessary in 2.5%. The rate of major adverse events was 3.1%. Thrombotic events occurred in 7 patients (4.3%) with 4 intra- and 4 postprocedural in-stent thromboses, respectively (1 patient had both peri- and postprocedural thrombosis). Of these thrombotic events, only 2 (1.2%) led to major adverse events (ischemic strokes). Postinterventional neurologic morbidity and mortality were observed in 1.9% and 1.2%, respectively. The rate of complete aneurysm occlusion after a mean follow-up of 7.0 months was 66.0%. CONCLUSIONS: The new FRED X is a safe and feasible device for aneurysm treatment. In this retrospective multicenter study, the rate of thrombotic complications was low, and the short-term occlusion rates are satisfactory.

4 July 2018 in Interventional Neuroradiology
Verified
Journal Article
Closed access
DVDominik F. Vollherbst
Dominik F. Vollherbst
RORuth Otto
Ruth Otto
TDThuy Do
Thuy Do
HKHans U Kauczor
Hans U Kauczor
MBMartin Bendszus
Martin Bendszus
MMMarkus A. Möhlenbruch
Markus A. Möhlenbruch
A frequently reported drawback of ethylene vinyl alcohol copolymer-based liquid embolic agents is the production of artifacts in diagnostic imaging. New embolic agents, such as Precipitating hydrophobic injectable liquid (PHIL; MicroVention, Tustin, CA, USA), are supposed to induce significantly fewer artifacts. The purpose of this study is to assess the degree of artifacts induced by the liquid embolic agents Onyx (Medtronic Neurovascular, Irvine, CA, USA) and PHIL in conventional computed tomography (CT), cone-beam CT and magnetic resonance imaging (MRI) in an experimental in vivo model. In 10 pigs the rete mirabile was embolized with Onyx (n = 5) or PHIL (n = 5). After embolization, conventional CT, cone-beam CT and MRI were performed. The degree of artifacts was graded qualitatively (five-point scale; for CT and MRI) and quantitatively (HUs of well-defined regions of interest (ROIs); for CT only). Artifacts were significantly more severe for Onyx both in the qualitative (e.g. conventional CT: 2 versus 5 (medians); p = 0.008) and in the quantitative image analysis (e.g. cone-beam CT: standard deviation of a ROI near to the embolic agent cast, 94 HU versus 38 HU (medians); p = 0.008). Neither Onyx nor PHIL produced any apparent artifacts in MRI. PHIL produces fewer artifacts than Onyx in conventional CT and cone-beam CT in an experimental in vivo model.

3 May 2018 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
DVDominik F. Vollherbst
Dominik F. Vollherbst
CUC. Ulfert
C. Ulfert
UNU. Neuberger
U. Neuberger
CHC. Herweh
C. Herweh
MLM. Laible
M. Laible
MMMarkus A. Möhlenbruch
Markus A. Möhlenbruch
BACKGROUND AND PURPOSE: Sinus-preserving endovascular embolization was described as a promising treatment technique for dural arteriovenous fistulas. Our aim was to report our single-center experience in patients with dural arteriovenous fistulas who were treated with transarterial liquid embolization in combination with transvenous balloon-assisted protection of the affected venous sinus. MATERIALS AND METHODS: A retrospective analysis of a prospectively collected data base was performed. Demographic and clinical data, angiographic features of the dural arteriovenous fistulas, procedural parameters, complications, treatment success, follow-up imaging, and clinical outcome were assessed. RESULTS: Twenty-two patients were treated in 25 procedures. All patients were symptomatic, of whom 81.8% presented with tinnitus; 9.1%, with ocular symptoms; and 9.1%, with headache. Most fistulas were located at the transverse and/or sigmoid sinus. The most frequent fistula type was Cognard IIa+b (40.9%), followed by Cognard I (31.8%) and Cognard IIa (27.3%)/Borden I (59.1%), followed by Borden II (40.9%). The affected sinus could be preserved in all except for 1 patient in whom it was sacrificed in a second treatment procedure by coil embolization. The overall complete occlusion rate was 86.4%. The overall complication rate was 20%, with transient and permanent morbidity and mortality of 8%, 0%, and 0%, respectively. After a mean follow-up of 18 months, most patients (68.2%) achieved complete symptom remission, 27.3% showed symptom relief, and 4.6% had stable symptoms. CONCLUSIONS: Transarterial liquid embolization of dural arteriovenous fistulas in combination with transvenous balloon-assisted protection of the venous sinus is feasible and safe and offers high rates of occlusion and of symptom remission.