Daniela Silva

Dr. Daniela Silva


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2019 in Chemosensors
Verified
Journal Article
Open access
PDF file
MCMalena Karla Lombello Coelho
Malena Karla Lombello Coelho
DSDaniela Silva
Daniela Silva
Arnaldo César PereiraArnaldo César Pereira
Arnaldo César Pereira
This work describes the development of an electrochemical sensor that was used in the determination of ethinyl estradiol (EE) in pharmaceutical formulations, river water, and milk using the square wave voltammetry technique. Studies were carried out using different carbonaceous materials (multiwalled carbon nanotubes, reduced graphene oxide Reduced graphene oxide, graphite) and different metallic phthalocyanines (cobalt, iron and manganese). Based on these studies it was possible to obtain the best system for the construction of the sensor. The device was obtained by the chemical modification of a glassy carbon electrode (GCE) with multiwalled carbon nanotubes (MWCNTs) and cobalt phthalocyanine (CoPc). The materials were characterized by scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FT-IR). Under conditions previously optimized for the proposed method, an analytical curve was constructed, presenting linearity in a range of 2.50–90.0 μmol L−1 (R = 0.990), with detection limit of 2.20 μmol L−1 and quantification of 2.50 μmol L−1. The validation of the methodology for the determination of EE using GCE-MWCNTs-CoPc was performed, being accurate, precise, stable and sensitive. The recovery of ethinyl estradiol in the sample of pharmaceutical formulation was 103.93%, in the samples of river water ranged from 92.75% to 96.47%, and in the milk sample was from 88.00% to 96.20%. Thus, the proposed method presented a viable alternative for the determination of ethinyl estradiol in the quality control of pharmaceutical and food formulations as well as in environmental control.

11 November 2024 in Analytica
Verified
Journal Article
Open access
PDF file
TCThaís Cândido
Thaís Cândido
DSDaniela Silva
Daniela Silva
MBMarcella Matos Cordeiro Borges
Marcella Matos Cordeiro Borges
TBThiago Gabry Barbosa
Thiago Gabry Barbosa
STScarlat Ohanna Dávila da Trindade
Scarlat Ohanna Dávila da Trindade
Arnaldo César PereiraArnaldo César Pereira
Arnaldo César Pereira
Three-dimensional printing technology has emerged as a versatile and cost-effective alternative for the fabrication of electrochemical sensors. To enhance sensor sensitivity and biocompatibility, a diverse range of biocompatible and conductive materials can be employed in these devices. This allows these sensors to be modified to detect a wide range of analytes in various fields. 3D-printed electrochemical sensors have the potential to play a pivotal role in personalized medicine by enabling the real-time monitoring of metabolite and biomarker levels. These data can be used to personalize treatment strategies and optimize patient outcomes. The portability and low-cost nature of 3D-printed electrochemical sensors make them suitable for point-of-care (POC) diagnostics. These tests enable rapid and decentralized analyses, aiding in diagnosis and treatment decisions in resource-limited settings. Among the techniques widely reported in the literature for 3D printing, the fused deposition modeling (FDM) technique is the most commonly used for the development of electrochemical devices due to the easy accessibility of equipment and materials. Focusing on the FDM technique, this review explores the critical factors influencing the fabrication of electrochemical sensors and discusses potential applications in clinical analysis, while acknowledging the challenges that need to be overcome for its effective adoption.

4 December 2023 in Analytica
Verified
Journal Article
Open access
PDF file
TCThaís Cândido
Thaís Cândido
Arnaldo César PereiraArnaldo César Pereira
Arnaldo César Pereira
DSDaniela Silva
Daniela Silva
This work developed a conductive ink composed of carbonaceous material for printing electrochemical sensors. The optimized ink comprises graphite, carbon black, and nail polish, respectively (35.3:11.7:53%), as well as acetone as a solvent. The proportion was optimized with consideration of the binder’s solubilization, the ink’s suitability for the screen-printing process, and lower electrical resistance. The materials used, and the resulting ink, were analyzed by way of Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), Raman spectroscopy, electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). The charge transfer resistance (Rct) obtained was 0.348 kΩ. The conductive ink was used to print an electrode on a PET substrate, and a flexible and disposable electrode was obtained. The electroactive area obtained was 13.7 cm2, which was calculated by the Randles-Sevcik equation. The applicability of the device was demonstrated with a redox probe, providing a sensitivity of 0.02 µ A L mmol−1. The conductive ink has adequate homogeneity for producing electrodes using the screen-printing technique, with a low estimated production cost of $ 0.09 mL−1.

2 March 2022 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
DSDaniela Silva
Daniela Silva
Arnaldo César PereiraArnaldo César Pereira
Arnaldo César Pereira
The purpose of this work was to apply an electrochemical sensor modified with a molecularly imprinted polymer (MIP) and carbon black (CB) for 17β-estradiol (E2) detection in river water samples. The synthesized MIP was characterized by Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM).The modification of the electrode with the MIP and CB contributed to increased sensitivity, an increase of over 173% in relation to that of the bare electrode. The experimental parameters, amount of modifiers, pH and possible interfering species were evaluated. The method showed linearity from 0.10 to 23.0 μmol L−1 and detection and quantification limits of 0.03 and 0.10 μmol L−1, respectively. The application of the developed sensor was considered simple, resulting in a fast, low operating cost method, with recovery values between 103 and 105%.

18 May 2021 in Electrochem
Verified
Journal Article
Open access
PDF file
EAEdna Ferreira Amaral
Edna Ferreira Amaral
DSDaniela Silva
Daniela Silva
Maria SilvaMaria Silva
Maria Silva
Arnaldo César PereiraArnaldo César Pereira
Arnaldo César Pereira
In this work, an electrochemical sensor (GCE/MWCNT/Fe3O4@SiO2) based on a composite of multiwalled carbon nanotubes (MWCNT) and an Fe3O4@SiO2 (MMN) nanocomposite on a glassy carbon electrode (GCE) was developed for the detection of tetracycline (TC). The composite formed promoted an increased electrochemical signal and the stability of the sensor, combining its individual characteristics such as high electrical conductivity and large surface area. The composite material was characterized by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), Mössbauer spectroscopy, and scanning electron microscope (SEM). The adsorptive stripping differential pulse voltammetry (AdSDPV) promoted better performance for the electrochemical sensor and greater sensitivity for TC detection. Under optimized conditions, the currents increased linearly with TC concentrations from 4.0 to 36 µmol L−1 (0.997) and from 40 to 64 µmol L−1 (0.994) with detection and quantification limits of 1.67 µmol L−1 and 4.0 µmol L−1, respectively. The sensor was applied in the analysis of milk and river water samples, obtaining recovery values ranging from 91–117%.

1 June 2024 in Analytica
Verified
Journal Article
Open access
PDF file
SOSthephane Pereira de Oliveira
Sthephane Pereira de Oliveira
TCThaís Cândido
Thaís Cândido
Arnaldo César PereiraArnaldo César Pereira
Arnaldo César Pereira
DSDaniela Silva
Daniela Silva
Catechol (CT) is a phenolic compound widely used in various industrial sectors, but it is toxic; thus, there is a need for methods that aim to identify and quantify the existence of residues of this material in the environment. In this study a disposable printed electrochemical sensor was developed as an effective alternative for determining CT in water samples. The electrode, called SPEC, was manufactured using the screen-printing method using polyethylene terephthalate (PET) as a support, in which a conductive ink based on carbonaceous materials was used to print the working and auxiliary electrodes and a silver/silver chloride of ink on the reference electrode. The optimal ratio for the conductive ink was 6.25% carbon black, 35.42% graphite, and 58.33% nail polish. The ink obtained was characterized by scanning electron microscopy (SEM). The assessment of the effect of pH on the redox process showed Nernstian behavior (0.057 V pH−1), indicating that the process involves the same number of protons and electrons. Under optimized conditions, with 0.2 mol L−1 acetate buffer at pH 5.0, and by square wave voltammetry, the sensor presented sensitivity values of 0.31 μA L μmol−1, a detection limit of 5.96 μmol L−1, and a quantification limit of 19.87 μmol L−1. The sensor was applied to determine CT in tap water samples, and the results showed recoveries between 97.95 and 100.17%.