Makram Obeid

Dr. Makram Obeid


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2019 in BMC Neuroscience
Verified
Journal Article
Open access
PDF file
YMYasser Medlej
Yasser Medlej
RARita Asdikian
Rita Asdikian
LWLara Wadi
Lara Wadi
HSHoussein Salah
Houssein Salah
LDLaura Dosh
Laura Dosh
MOMakram Obeid
Makram Obeid
The electroencephalogram (EEG) is a widely used laboratory technique in rodent models of epilepsy, traumatic brain injury (TBI), and other neurological diseases accompanied by seizures. Obtaining prolonged continuous EEG tracings over weeks to months is essential to adequately answer research questions related to the chronobiology of seizure emergence, and to the effect of potential novel treatment strategies. Current EEG recording methods include wired and the more recent but very costly wireless technologies. Wired continuous long-term EEG in rodents remains the mainstay approach but is often technically challenging due to the notorious frequent EEG cable disconnections from the rodent’s head, and to poor signal-to-noise ratio especially when simultaneously monitoring multiple animals. Premature EEG cable disconnections and cable movement-related artifacts result from the animal’s natural mobility, and subsequent tension on the EEG wires, as well as from potential vigorous and frequent seizures. These challenges are often accompanied by injuries to the scalp, and result in early terminations of costly experiments. Here we describe an enhanced customized swivel-balance EEG-cage system that allows tension-free rat mobility. The cage setup markedly improves the safety and longevity of current existing wired continuous long-term EEG. Prevention of EEG cable detachments is further enhanced by a special attention to surgical electrode anchoring to the skull. In addition to mechanically preventing premature disconnections, the detailed stepwise approach to the electrical shielding, wiring and grounding required for artifact-free high signal-to-noise ratio recordings is also included. The successful application of our EEG cage system in various rat models of brain insults and epilepsy is described with illustrative high quality tracings of seizures and electrographic patterns obtained during continuous and simultaneous monitoring of multiple rats early and up to 3 months post-brain insult. Our simple-to-implement key modifications to the EEG cage setup allow the safe acquisition of substantial high quality wired EEG data without resorting to the still costly wireless technologies.

1 March 2019 in Epilepsy & Behavior
Verified
Journal Article
Closed access
YMYasser Medlej
Yasser Medlej
HSHoussein Salah
Houssein Salah
LWLara Wadi
Lara Wadi
SSSarah Saad
Sarah Saad
BBBashir Bashir
Bashir Bashir
MOMakram Obeid
Makram Obeid

15 August 2024 in ACS Applied Materials & Interfaces
Verified
Journal Article
Open access
FKFadi Khoury
Fadi Khoury
SSSahera Saleh
Sahera Saleh
HBHeba Badawe
Heba Badawe
MOMakram Obeid
Makram Obeid
MKMassoud Khraiche
Massoud Khraiche
Organic electrochemical transistors (OECTs) have emerged as powerful tools for biosignal amplification, including electrocorticography (ECoG). However, their widespread application has been limited by the complexities associated with existing fabrication techniques, restricting accessibility and scalability. Here, we introduce a novel all-planar, all-printed high-performance OECT device that significantly enhances the accuracy and sensitivity of ECoG recordings. Achieved through an innovative three-step drop-on-demand inkjet printing process on flexible substrates, our device offers a rapid response time of 0.5 ms, a compact channel area of 1950 μm2, and is characterized by a transconductance of 11 mS. This process not only simplifies integration but also reduces costs. Our optimized in-plane gate voltage control facilitates operation at peak transconductance, which elevates the signal-to-noise ratio (SNR) by up to 133%. In vivo evaluations in a rat model of seizure demonstrate the device's performance in recording distinct electrographic phases, surpassing the capabilities of PEDOT:PSS-coated gold-based ultralow impedance passive electrodes, achieving a high SNR of 48 db. Our results underscore the potential of Inkjet-printed OECTs in advancing the accessibility and accuracy of diagnostic tools that could enhance patient care by facilitating timely detection of neurological conditions.

15 September 2007 in Pediatric Radiology
Verified
Journal Article
Closed access
PDF file
MOMakram Obeid
Makram Obeid
JFJeremy Franklin
Jeremy Franklin
SSShraddha Shrestha
Shraddha Shrestha
LJLara Johnson
Lara Johnson
FQFrank Quattromani
Frank Quattromani
DHDaniel Hurst
Daniel Hurst

5 July 2019
Verified
Book Chapter
Closed access
PDF file
YMYasser Medlej
Yasser Medlej
HSHoussein Salah
Houssein Salah
LWLara Wadi
Lara Wadi
SSSarah Saad
Sarah Saad
RARita Asdikian
Rita Asdikian
MOMakram Obeid
Makram Obeid

24 July 2017 in Current Treatment Options in Neurology
Verified
Journal Article
Closed access
PDF file
LALama Assi
Lama Assi
YSYoussef Saklawi
Youssef Saklawi
PKPascale E. Karam
Pascale E. Karam
MOMakram Obeid
Makram Obeid