Jakub Nedbal

Dr. Jakub Nedbal

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2014 in Cytometry Part A
Verified
Journal Article
Open access
PDF file
JNJakub Nedbal
Jakub Nedbal
VVViput Visitkul
Viput Visitkul
EOElena Ortiz‐Zapater
Elena Ortiz‐Zapater
GWGregory Weitsman
Gregory Weitsman
PCPrabhjoat Chana
Prabhjoat Chana
SASimon M. Ameer‐Beg
Simon M. Ameer‐Beg
Sensing ion or ligand concentrations, physico‐chemical conditions, and molecular dimerization or conformation change is possible by assays involving fluorescent lifetime imaging. The inherent low throughput of imaging impedes rigorous statistical data analysis on large cell numbers. We address this limitation by developing a fluorescence lifetime‐measuring flow cytometer for fast fluorescence lifetime quantification in living or fixed cell populations. The instrument combines a time‐correlated single photon counting epifluorescent microscope with microfluidics cell‐handling system. The associated computer software performs burst integrated fluorescence lifetime analysis to assign fluorescence lifetime, intensity, and burst duration to each passing cell. The maximum safe throughput of the instrument reaches 3,000 particles per minute. Living cells expressing spectroscopic rulers of varying peptide lengths were distinguishable by Förster resonant energy transfer measured by donor fluorescence lifetime. An epidermal growth factor (EGF)‐stimulation assay demonstrated the technique's capacity to selectively quantify EGF receptor phosphorylation in cells, which was impossible by measuring sensitized emission on a standard flow cytometer. Dual‐color fluorescence lifetime detection and cell‐specific chemical environment sensing were exemplified using di‐4‐ANEPPDHQ, a lipophilic environmentally sensitive dye that exhibits changes in its fluorescence lifetime as a function of membrane lipid order. To our knowledge, this instrument opens new applications in flow cytometry which were unavailable due to technological limitations of previously reported fluorescent lifetime flow cytometers. The presented technique is sensitive to lifetimes of most popular fluorophores in the 0.5–5 ns range including fluorescent proteins and is capable of detecting multi‐exponential fluorescence lifetime decays. This instrument vastly enhances the throughput of experiments involving fluorescence lifetime measurements, thereby providing statistically significant quantitative data for analysis of large cell populations. © 2014 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of ISAC.

27 March 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JNJakub Nedbal
Jakub Nedbal
FRFrancesco Mattioli Della Rocca
Francesco Mattioli Della Rocca
IIIveta T. Ivanova
Iveta T. Ivanova
AAAndrew Allan
Andrew Allan
JGJeremy Graham
Jeremy Graham
KSKlaus Suhling
Klaus Suhling
A wide-field microscope with epi-fluorescence and selective plane illumination was combined with a single-photon avalanche diode (SPAD) array camera to enable live-cell fluorescence lifetime imaging (FLIM) using time-correlated single-photon counting (TCSPC). The camera sensor comprised of $$\text {192}\times \text {128}$$ 192 × 128 pixels, each integrating a single SPAD and a time-to-digital converter. Jointly, they produced a stream of single-photon images of photon arrival times with $$\approx \text {38 ps}$$ ≈ 38 ps accuracy. The photon arrival times were subject to systematic delays and nonlinearities, which were corrected by a Monte-Carlo algorithm. The SPAD camera was then applied to FLIM where histogramming the resulting photon arrival times in each pixel resulted in decays compatible with common data processing pipelines for fluorescence lifetime analysis. The capabilities of the TCSPC camera-based FLIM microscope were demonstrated by imaging living unicellular photosynthetic algae and artificial lipid vesicles. Epi-fluorescence illumination enabled rapid fluorescence lifetime imaging of living cells and selective-plane illumination enabled 3-dimensional FLIM of stationary samples.

1 October 2020 in HardwareX
Verified
Journal Article
Open access
JNJakub Nedbal
Jakub Nedbal
LGLu Gao
Lu Gao
KSKlaus Suhling
Klaus Suhling
A bottom-illuminated orbital shaker designed for the cultivation of microalgae suspensions is described in this open-source hardware report. The instrument agitates and illuminates microalgae suspensions grown inside flasks. It was optimized for low production cost, simplicity, low power consumption, design flexibility, consistent, and controllable growth light intensity.

14 December 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JNJakub Nedbal
Jakub Nedbal
PHPhilip S. Hobson
Philip S. Hobson
DFDavid J. Fear
David J. Fear
RHRainer Heintzmann
Rainer Heintzmann
HGHannah J Gould
Hannah J Gould
We present a web engine boosted fluorescence in-situ hybridization (webFISH) algorithm using a genome-wide sequence similarity search to design target-specific single-copy and repetitive DNA FISH probes. The webFISH algorithm featuring a user-friendly interface (http://www.webfish2.org/) maximizes the coverage of the examined sequences with FISH probes by considering locally repetitive sequences absent from the remainder of the genome. The highly repetitive human immunoglobulin heavy chain sequence was analyzed using webFISH to design three sets of FISH probes. These allowed direct simultaneous detection of class switch recombination in both immunoglobulin-heavy chain alleles in single cells from a population of cultured primary B cells. It directly demonstrated asynchrony of the class switch recombination in the two alleles in structurally preserved nuclei while permitting parallel readout of protein expression by immunofluorescence staining. This novel technique offers the possibility of gaining unprecedented insight into the molecular mechanisms involved in class switch recombination.

16 June 2023 in Heritage Science
Verified
Journal Article
Open access
PDF file
CWChristine B. Wilda
Christine B. Wilda
ABAviva Burnstock
Aviva Burnstock
KSKlaus Suhling
Klaus Suhling
FRFrancesco Mattioli Della Rocca
Francesco Mattioli Della Rocca
RHRobert K. Henderson
Robert K. Henderson
JNJakub Nedbal
Jakub Nedbal
The removal of varnish from the surface is a key step in painting conservation. Varnish removal is traditionally monitored by examining the painting surface under ultraviolet illumination. We show here that by imaging the fluorescence lifetime instead, much better contrast, sensitivity, and specificity can be achieved. For this purpose, we developed a lightweight (4.8 kg) portable instrument for macroscopic fluorescence lifetime imaging (FLIM). It is based on a time-correlated single-photon avalanche diode (SPAD) camera to acquire the FLIM images and a pulsed 440 nm diode laser to excite the varnish fluorescence. A historical model painting was examined to demonstrate the capabilities of the system. We found that the FLIM images provided information on the distribution of the varnish on the painting surface with greater sensitivity, specificity, and contrast compared to the traditional ultraviolet illumination photography. The distribution of the varnish and other painting materials was assessed using FLIM during and after varnish removal with different solvent application methods. Monitoring of the varnish removal process between successive solvent applications by a swab revealed an evolving image contrast as a function of the cleaning progress. FLIM of dammar and mastic resin varnishes identified characteristic changes to their fluorescence lifetimes depending on their ageing conditions. Thus, FLIM has a potential to become a powerful and versatile tool to visualise varnish removal from paintings. Graphical Abstract

19 February 2020
Verified
Preprint
Open access
PDF file
JNJakub Nedbal
Jakub Nedbal
The cooled LED illuminator is a large heatsink with self-adhesive LED strips, four axial fans, and the LED controller attached to it. This document is part of the Illuminated Orbital Shaker for Microalgae Culture project: Procuring Parts for Algal Shaker Assembling LED Controller Electronics 3D Printing Case for LED Controller Assembling Cooled LED Illuminator (this document) Cutting and Drilling Clear Acrylic Sheet Assembling Algal Shaker