Oduces a higher ACL strain than either moment applied individually, the combined rotational moments at the physiological levels observed could theoretically increase strain in the ACL high enough to rupture the ACL, and the location of the peak contact force was at the posterior-lateral side for combined loading. Methods: The study was conducted by applying in vivo human loading data to a validated simulation model of the three-dimensional dynamic knee joint to predict ACL strains. Results: The peak ACL strain increased nonlinearly when either applied valgus moment or internal rotation moment was increased in the model. When the two rotational moments were applied individually, neither caused ACL strain >0.077. However, when applied in combination, the two rotational moments had a much larger effect, and the predicted peak ACL strain increased up to 0.105. During landing, the peak contact force occurred at the posterior-lateral side of the tibial cartilage in the model when the combined maximum valgus moment and tibial internal rotation moments were applied. Conclusions: Combined knee valgus and internal rotation moments increases ACL strain more than either alone. The combination of a valgus and internal rotational moment at magnitudes that occurs in vivo during landing can cause ACL strains that may be high enough to cause ACL rupture. This predicted high ACL strain and the contact force location suggest that combined valgus and internal tibial rotational moments during single-leg landing are relevant to ACL injuries....
Purpose: To investigate the effect of acute loading on in vivo tibiofemoral contact area changes in both compartments, and to determine whether in vivo tibiofemoral contact area differs between subjects with medial knee osteoarthritis (OA) and healthy controls.Materials and Methods: Ten subjects with medial knee OA (KL3) and 11 control subjects (KL0) were tested. Coronal three‐dimensional spoiled gradient‐recalled (3D‐SPGR) and T2‐weighted fast spin‐echo FSE magnetic resonance imaging (MRI) of the knee were acquired under both unloaded and loaded conditions. Tibiofemoral cartilage contact areas were measured using image‐based 3D models.Results: Tibiofemoral contact areas in both compartments significantly increased under loading (P < 0.001) and the increased contact area in the medial compartment was significantly larger than in the lateral compartment (P < 0.05). Medial compartment contact area was significantly larger in KL3 subjects than KL0 subjects, both at unloaded and loaded conditions (P < 0.05). Contact areas measured from 3D‐SPGR and T2‐weighted FSE images were strongly correlated (r = 0.904).Conclusion: Females with medial OA increased tibiofemoral contact area in the medial compartment compared to healthy subjects under both unloaded and loaded conditions. The contact area data presented in this study may provide a quantitative reference for further cartilage contact biomechanics such as contact stress analysis and cartilage biomechanical function difference between osteoarthritic and healthy knees. J. Magn. Reson. Imaging 2011;.