Chien-Nan Lin

Prof. Chien-Nan Lin


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2016 in Energies
Verified
Journal Article
Open access
PDF file
CLChien-Nan Lin
Chien-Nan Lin
JJJiin-Yuh Jang
Jiin-Yuh Jang
JLJin-Sheng Leu
Jin-Sheng Leu
Heat dissipation per unit volume has grown rapidly, as the size of modern electronic devices has continued to decrease. The air flow induced by an oscillating cantilever blade enhances the heat transfer performance of high heat density devices. The heat transfer improvement mainly depends on the velocity magnitude and distribution of air streams induced by the vibrating blade. Accordingly, this study numerically and experimentally examines the time-varying flow characteristics of a vibrating cantilever for five blade types. The blades are rectangular or trapezoidal with various widths and actuated at various frequencies. The fluid domain is numerically discretized using a dynamic meshing scheme to model the three-dimensional time-varying vibrating blade. The experiment utilizes nine hot-wire velocity meters to measure the average velocities. The flow structure with streamlines and velocity contours of the induced air flow are determined at various section planes. The results show that a major maximum-velocity region appears around the blade tip and that four minor local-maximum-velocity regions appear at the four corners. In addition, the width and width ratio of the blade significantly affects the velocity distribution of the flow induced by the vibrating cantilever blade.

6 March 2015 in Heat Transfer Engineering
Verified
Journal Article
Closed access
CLChien-Nan Lin
Chien-Nan Lin
JLJin-Sheng Leu
Jin-Sheng Leu
Piezoelectric fans are an effective device for heat transfer enhancement in low convective regions due to their low power consumption, low noise, and operational simplicity. This study performs a numerical and experimental investigation into the effects of a piezoelectric fan on the velocity and temperature fields near a cylindrical heat source with a constant heat flux on the sidewalls and upper flat surface. In performing the investigation, the blade is placed at various locations along the cylindrical axis and is arranged such that it vibrates in either the vertical direction or the horizontal direction. The results show that the airstream induced by the vibrating fan covers a broader area of the heated surface when the blade vibrates in the vertical direction, and therefore yields a better heat transfer performance than that achieved when the fan vibrates in the horizontal direction. In addition, it is found that the maximum heat transfer augmentation ratio is obtained at dimensionless fan positions ranging from 0.6 to 0.75, and has values of 1.94, 1.53, and 1.44 given dimensionless fan tip clearances of 0.5, 1.0, and 1.5, respectively. Finally, it is shown that while the numerical results underestimate the effect of the vibrating piezoelectric fan in enhancing the heat transfer performance by around 1–14%, a good qualitative agreement is observed between the numerical and experimental results.

25 November 2016 in Energies
Verified
Journal Article
Open access
PDF file
CLChien-Nan Lin
Chien-Nan Lin
JJJiin-Yuh Jang
Jiin-Yuh Jang
YLYi-Shiun Lai
Yi-Shiun Lai
Packed bed is widely used for different industries and technologies, such as heat exchangers, heat recovery, thermal energy storage and chemical reactors. In modern steel industry, packed bed regenerator is widely utilized in the reheating furnace to increase the furnace efficiency. This study established a two dimensional numerical model to simulate a packed bed used in regenerative furnaces. The physical properties of fluids and packed stuffing (such as density, thermal conductivity, and specific heat) are considered as functions of temperature to adapt the large temperature variation in operation. The transient temperature profiles of the flue gas, packed bed, and air during the heating and regeneration period are examined for various switching time (30, 60, 120, and 240 s). The results reveal that, during the heating period, the spanwise averaged heat transfer coefficient is decreased along the longitudinal downstream direction, while during the regeneration period, the opposite trend is true. Moreover, the regenerator thermal effectiveness is decreased by increasing the switching time.