FRANCOIS PONTANA

Prof. Dr. FRANCOIS PONTANA

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2008 in Academic Radiology
Verified
Journal Article
Closed access
FPFRANCOIS PONTANA
FRANCOIS PONTANA
JFJean-Baptiste Faivre
Jean-Baptiste Faivre
MRMartine Remy-Jardin
Martine Remy-Jardin
TFThomas Flohr
Thomas Flohr
BSBernhard Schmidt
Bernhard Schmidt
JRJacques Remy
Jacques Remy

16 November 2010 in European Radiology
Verified
Journal Article
Closed access
PDF file
FPFRANCOIS PONTANA
FRANCOIS PONTANA
ADAlain Duhamel
Alain Duhamel
JPJulien Pagniez
Julien Pagniez
TFThomas Flohr
Thomas Flohr
JFJean-Baptiste Faivre
Jean-Baptiste Faivre
MRMartine Remy-Jardin
Martine Remy-Jardin

9 March 2021 in Circulation
Verified
Journal Article
Closed access
PDF file
Flavien VincentFlavien Vincent
Flavien Vincent
JTJulien Ternacle
Julien Ternacle
TDTom Denimal
Tom Denimal
MSMylène Shen
Mylène Shen
BRBjorn Redfors
Bjorn Redfors
EBEric Van Belle
Eric Van Belle
After 15 years of successive randomized, controlled trials, indications for transcatheter aortic valve replacement (TAVR) are rapidly expanding. In the coming years, this procedure could become the first line treatment for patients with a symptomatic severe aortic stenosis and a tricuspid aortic valve anatomy. However, randomized, controlled trials have excluded bicuspid aortic valve (BAV), which is the most frequent congenital heart disease occurring in 1% to 2% of the total population and representing at least 25% of patients 80 years of age or older referred for aortic valve replacement. The use of a less invasive transcatheter therapy in this elderly population became rapidly attractive, and approximately 10% of patients currently undergoing TAVR have a BAV. The U.S. Food and Drug Administration and the “European Conformity” have approved TAVR for low-risk patients regardless of the aortic valve anatomy whereas international guidelines recommend surgical replacement in BAV populations. Given this progressive expansion of TAVR toward younger and lower-risk patients, heart teams are encountering BAV patients more frequently, while the ability of this therapy to treat such a challenging anatomy remains uncertain. This review will address the singularity of BAV anatomy and associated technical challenges for the TAVR procedure. We will examine and summarize available clinical evidence and highlight critical knowledge gaps regarding TAVR utilization in BAV patients. We will provide a comprehensive overview of the role of computed tomography scans in the diagnosis, and classification of BAV and TAVR procedure planning. Overall, we will offer an integrated framework for understanding the current role of TAVR in the treatment of bicuspid aortic stenosis and for guiding physicians in clinical decision-making.

5 November 2010 in European Radiology
Verified
Journal Article
Open access
PDF file
FPFRANCOIS PONTANA
FRANCOIS PONTANA
JPJulien Pagniez
Julien Pagniez
TFThomas Flohr
Thomas Flohr
JFJean-Baptiste Faivre
Jean-Baptiste Faivre
ADAlain Duhamel
Alain Duhamel
MRMartine Remy-Jardin
Martine Remy-Jardin
To assess noise reduction achievable with an iterative reconstruction algorithm. 32 consecutive chest CT angiograms were reconstructed with regular filtered back projection (FBP) (Group 1) and an iterative reconstruction technique (IRIS) with 3 (Group 2a) and 5 (Group 2b) iterations. Objective image noise was significantly reduced in Group 2a and Group 2b compared with FBP (p < 0.0001). There was a significant reduction in the level of subjective image noise in Group 2a compared with Group 1 images (p < 0.003), further reinforced on Group 2b images (Group 2b vs Group 1; p < 0.0001) (Group 2b vs Group 2a; p = 0.0006). The overall image quality scores significantly improved on Group 2a images compared with Group 1 images (p = 0.0081) and on Group 2b images compared with Group 2a images (p < 0.0001). Comparative analysis of individual CT features of mild lung infiltration showed improved conspicuity of ground glass attenuation (p < 0.0001), ill-defined micronodules (p = 0.0351) and emphysematous lesions (p < 0.0001) on Group 2a images, further improved on Group 2b images for ground glass attenuation (p < 0.0001), and emphysematous lesions (p = 0.0087). Compared with regular FBP, iterative reconstructions enable significant reduction of image noise without loss of diagnostic information, thus having the potential to decrease radiation dose during chest CT examinations.

1 April 2013 in Radiology
Verified
Journal Article
Closed access
MDMarie-Aurélie Delesalle
Marie-Aurélie Delesalle
FPFRANCOIS PONTANA
FRANCOIS PONTANA
ADAlain Duhamel
Alain Duhamel
JFJean-Baptiste Faivre
Jean-Baptiste Faivre
TFThomas Flohr
Thomas Flohr
MRMartine Remy-Jardin
Martine Remy-Jardin
To determine the energy levels that provide optimal imaging of thoracic circulation at dual-energy computed tomographic (CT) angiography with reduced iodine load in comparison with a standard technique. The institutional review board approved the study with waiver of patient consent. Eighty patients underwent a dual-source, dual-energy CT examination after administration of low-concentration contrast material (170 mg of iodine per milliliter), and eight series of images were reconstructed, including the original polychromatic images at 80 and 140 kV and six series of virtual monochromatic spectral images at 50, 60, 70, 80, 90, and 100 keV. For each vascular compartment, the energy level that provided optimal evaluation on virtual monochromatic spectral images was determined, and these series were compared with the polychromatic dual-energy images and with standard chest CT images that were used as controls. Comparisons between groups were performed by using the paired Student t test for continuous variables and the McNemar test for categorical variables. Comparisons between dual-energy and standard CT images were performed by using the unpaired Student t test for continuous variables and the χ(2) test for categorical variables. For the aorta, pulmonary arteries, and veins, the reconstruction at 60 keV provided adequate attenuation without marked beam-hardening artifacts in 90% of patients, with the highest contrast-to-noise and signal-to-noise ratios, the lowest level of subjective noise, and no significant differences with images at 80 kV (mean energy, 54 keV). For the superior vena cava and brachiocephalic veins, the reconstructions at 100 keV enabled artifact-free analysis of the perivascular anatomic zone without a significant difference with images at 140 kV (mean energy, 92 keV). Compared with standard CT images acquired after administration of a 35% iodinated contrast agent, there was a statistically significant reduction in the frequency of artifacts around systemic veins at 100 keV (P < .001) and similar overall image quality for central vessels at 60 keV (P > .05). An optimal analysis of thoracic circulation can be achieved on virtual monochromatic spectral images at 60 keV and 100 keV and on the original polychromatic images at 80 kV and 140 kV. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120195/-/DC1.

1 May 2020 in Journal of Cardiovascular Computed Tomography
Verified
Journal Article
Open access
RSR. Schofield
R. Schofield
LKL. King
L. King
UTU. Tayal
U. Tayal
ICI. Castellano
I. Castellano
JSJ. Stirrup
J. Stirrup
ENE. Nicol
E. Nicol
Image reconstruction is an increasingly complex field in CT. Iterative Reconstruction (IR) is at present an adjunct to standard Filtered Back Projection (FBP) reconstruction, but could become a replacement for it. Due to its potential for scanning at lower radiation doses, IR has received a lot of attention in the medical literature and all vendors offer commercial solutions. Its use in cardiovascular CT has been driven in part due to concerns about radiation dose and image quality. This paper is the first manuscript of a pair. It aims to review the basic principles of CT scanning, to describe image reconstruction using Filtered Back Projection, and to identify the physical processes that contribute to image noise which IR may be able to compensate for. The aim is to enable cardiovascular imagers to understand what happens to the raw data prior to the reconstruction process so they may have a better appreciation of the strengths and weaknesses of the various reconstruction techniques available. The second manuscript of this pair will discuss the various vendor permutations of IR in more detail, including the most recent machine learning based offerings, and critically appraise the current clinical research available on the various IR techniques used in cardiovascular CT.