Marco Bertolini

Dr. Marco Bertolini

AUSL IRCCS REGGIO EMILIA, Reggio Emilia, Emilia-Romagna, Italy
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2008 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
GZG. Zuccoli
G. Zuccoli
DCD. Santa Cruz
D. Santa Cruz
MBMarco Bertolini
Marco Bertolini
ARA. Rovira
A. Rovira
MGM. Gallucci
M. Gallucci
NPN. Pipitone
N. Pipitone
BACKGROUND AND PURPOSE: Wernicke encephalopathy (WE) is a severe neurologic disorder resulting from dietary vitamin B1 deficiency. This study was undertaken to analyze and compare MR imaging findings and neurologic manifestations at clinical presentations of patients with WE with and without a history of alcohol abuse.

1 August 2007 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
GZG. Zuccoli
G. Zuccoli
MGM. Gallucci
M. Gallucci
JCJ. Capellades
J. Capellades
LRL. Regnicolo
L. Regnicolo
BTB. Tumiati
B. Tumiati
MBMarco Bertolini
Marco Bertolini
BACKGROUND AND PURPOSE: Wernicke encephalopathy is a severe neurologic disorder that results from a dietary vitamin B1 deficiency. It is characterized by changes in consciousness, ocular abnormalities, and ataxia. This study was undertaken to analyze and compare findings on MR imaging and neurologic symptoms at clinical presentations of patients with Wernicke encephalopathy with and without a history of alcohol abuse.

23 February 2007 in Journal of Digital Imaging
Verified
Journal Article
Open access
PDF file
ANAndrea Nitrosi
Andrea Nitrosi
GBGiovanni Borasi
Giovanni Borasi
FNFranco Nicoli
Franco Nicoli
GMGino Modigliani
Gino Modigliani
ABAndrea Botti
Andrea Botti
PNPietro Notari
Pietro Notari
Reggio Emilia hospital installed Picture Archiving and Communications Systems (PACS) as the final step towards a completely digital clinical environment completing the HIS/EMR and 1,400 web/terminals for patient information access. Financial benefits throughout the hospital were assessed upfront and measured periodically. Key indicators (radiology exam turnaround time, number of radiology procedures performed, inpatients length of stay before and after the PACS implementation, etc.) were analyzed and values were statistically tested to assess workflow and productivity improvements. The hospital went “filmless” in 28 weeks. Between the half of 2004 and the respective period in 2003, overall Radiology Department productivity increased by 12%, TAT improved by more than 60%. Timelier patient care resulted in decreased lengths of stay. Neurology alone experienced a 12% improvement in average patient stay. To quantify the impact of PACS on the average hospital stays and the expected productivity benefits to inpatient productivity were used a “high level” and a “detailed” business model. Annual financial upsides have exceeded $1.9 millions/year. A well-planned PACS deployment simplifies imaging workflow and improves patient care throughout the hospital while delivering substantial financial benefits. Staff buy-in was the key in this process and on-going training and process monitoring are a must.

19 October 2006 in Medical Physics
Verified
Journal Article
Closed access
SRStefano Rivetti
Stefano Rivetti
NLNico Lanconelli
Nico Lanconelli
RCRenato Campanini
Renato Campanini
MBMarco Bertolini
Marco Bertolini
GBGianni Borasi
Gianni Borasi
SMStefania Maggi
Stefania Maggi

26 July 2024 in Cancers
Verified
Journal Article
Open access
PDF file
VTValeria Trojani
Valeria Trojani
MBMaria Chiara Bassi
Maria Chiara Bassi
LVLaura Verzellesi
Laura Verzellesi
MBMarco Bertolini
Marco Bertolini
Background: Lately, radiomic studies featuring the development of a signature to use in prediction models in diagnosis or prognosis outcomes have been increasingly published. While the results are shown to be promising, these studies still have many pitfalls and limitations. One of the main issues of these studies is that radiomic features depend on how the images are preprocessed before their computation. Since, in widely known and used software for radiomic features calculation, it is possible to set these preprocessing parameters before the calculation of the radiomic feature, there are ongoing studies assessing the stability and repeatability of radiomic features to find the most suitable preprocessing parameters for every used imaging modality. Materials and Methods: We performed a comprehensive literature search using four electronic databases: PubMed, Cochrane Library, Embase, and Scopus. Mesh terms and free text were modeled in search strategies for databases. The inclusion criteria were studies where preprocessing parameters’ influence on feature values and model predictions was addressed. Records lacking information on image acquisition parameters were excluded, and any eligible studies with full-text versions were included in the review process, while conference proceedings and monographs were disregarded. We used the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) tool to investigate the risk of bias. We synthesized our data in a table divided by the imaging modalities subgroups. Results: After applying the inclusion and exclusion criteria, we selected 43 works. This review examines the impact of preprocessing parameters on the reproducibility and reliability of radiomic features extracted from multimodality imaging (CT, MRI, CBCT, and PET/CT). Standardized preprocessing is crucial for consistent radiomic feature extraction. Key preprocessing steps include voxel resampling, normalization, and discretization, which influence feature robustness and reproducibility. In total, 44% of the included works studied the effects of an isotropic voxel resampling, and most studies opted to employ a discretization strategy. From 2021, several studies started selecting the best set of preprocessing parameters based on models’ best performance. As for comparison metrics, ICC was the most used in MRI studies in 58% of the screened works. Conclusions: From our work, we highlighted the need to harmonize the use of preprocessing parameters and their values, especially in light of future studies of prospective studies, which are still lacking in the current literature.

15 April 2014 in Medical Physics
Verified
Journal Article
Closed access
BDBruno Donini
Bruno Donini
SRStefano Rivetti
Stefano Rivetti
NLNico Lanconelli
Nico Lanconelli
MBMarco Bertolini
Marco Bertolini