Delivery of drugs and nanomedicines to tumors is often heterogeneous and insufficient and, thus, of limited efficacy. Microbubbles in combination with ultrasound have been found to improve delivery to tumors, enhancing accumulation and penetration. We used a subcutaneous prostate cancer xenograft model in mice to investigate the effect of free and nanoparticle-encapsulated cabazitaxel in combination with ultrasound and microbubbles with a lipid shell or a shell of nanoparticles. Sonopermeation reduced tumor growth and prolonged survival (26%-100%), whether the free drug was co-injected with lipid-shelled microbubbles or the nanoformulation was co-injected with lipid-shelled or nanoparticle-shelled microbubbles. Coherently with the improved therapeutic response, we found enhanced uptake of nanoparticles directly after ultrasound treatment that lasted several weeks (2.3 × -15.8 × increase). Neither cavitation dose nor total accumulation of nanoparticles could explain the variation within treatment groups, emphasizing the need for a better understanding of the tumor biology and mechanisms involved in ultrasound-mediated treatment.
Purpose: Meningiomas are the most common type of primary brain tumor, accounting for ~30% of all brain tumors. A substantial number of these tumors are never surgically removed but rather monitored over time. Automatic and precise meningioma segmentation is, therefore, beneficial to enable reliable growth estimation and patient-specific treatment planning.Methods: In this study, we propose the inclusion of attention mechanisms on top of a U-Net architecture used as backbone: (i) Attention-gated U-Net (AGUNet) and (ii) Dual Attention U-Net (DAUNet), using a three-dimensional (3D) magnetic resonance imaging (MRI) volume as input. Attention has the potential to leverage the global context and identify features' relationships across the entire volume. To limit spatial resolution degradation and loss of detail inherent to encoder–decoder architectures, we studied the impact of multi-scale input and deep supervision components. The proposed architectures are trainable end-to-end and each concept can be seamlessly disabled for ablation studies.Results: The validation studies were performed using a five-fold cross-validation over 600 T1-weighted MRI volumes from St. Olavs Hospital, Trondheim University Hospital, Norway. Models were evaluated based on segmentation, detection, and speed performances, and results are reported patient-wise after averaging across all folds. For the best-performing architecture, an average Dice score of 81.6% was reached for an F1-score of 95.6%. With an almost perfect precision of 98%, meningiomas smaller than 3 ml were occasionally missed hence reaching an overall recall of 93%.Conclusion: Leveraging global context from a 3D MRI volume provided the best performances, even if the native volume resolution could not be processed directly due to current GPU memory limitations. Overall, near-perfect detection was achieved for meningiomas larger than 3 ml, which is relevant for clinical use. In the future, the use of multi-scale designs and refinement networks should be further investigated. A larger number of cases with meningiomas below 3 ml might also be needed to improve the performance for the smallest tumors.
6 March 2022 in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
As lung cancer evolves, the presence of potentially malignant lymph nodes must be assessed to properly estimate disease progression and select the best treatment strategy. A method for accurate and automatic segmentation is hence decisive for quantitatively describing lymph nodes. In this study, the use of 3D convolutional neural networks, either through slab-wise schemes or the leveraging of downsampled entire volumes, is investigated. As lymph nodes have similar attenuation values to nearby anatomical structures, we use the knowledge of other organs as prior information to guide the segmentation. To assess the performances, a 5-fold cross-validation strategy was followed over a dataset of 120 contrast-enhanced CT volumes. For the 1178 lymph nodes with a short-axis diameter mm, our best-performing approach reached a patient-wise recall of 92%, a false positive per patient ratio of 5 and a segmentation overlap of 80.5%. Fusing a slab-wise and a full volume approach within an ensemble scheme generated the best performances. The anatomical priors guiding strategy is promising, yet a larger set than four organs appears needed to generate an optimal benefit. A larger dataset is also mandatory given the wide range of expressions a lymph node can exhibit (i.e. shape, location and attenuation).
Deep convolutional neural networks have quickly become the standard for medical image analysis. Although there are many frameworks focusing on training neural networks, there are few that focus on high performance inference and visualization of medical images. Neural network inference requires an inference engine (IE), and there are currently several IEs available including Intel's OpenVINO, NVIDIA's TensorRT, and Google's TensorFlow which supports multiple backends, including NVIDIA's cuDNN, AMD's ROCm and Intel's MKL-DNN. These IEs only work on specific processors and have completely different application programming interfaces (APIs). In this paper, we presents methods for extending FAST, an open-source high performance framework for medical imaging, to use any IE with a common programming interface. Thereby making it easier for users to deploy and test their neural networks on different processors. This article provides an overview of current IEs and how they can be combined with existing software such as FAST. The methods are demonstrated and evaluated on three performance demanding medical use cases: real-time ultrasound image segmentation, computed tomography (CT) volume segmentation, and patch-wise classification of whole slide microscopy images. Runtime performance was measured on the three use cases with several different IEs and processors. This revealed that the choice of IE and processor can affect performance of medical neural network image analysis considerably. In the most extreme case of processing 171 ultrasound frames, the difference between the fastest and slowest configuration were half a second vs. 24 seconds. For volume processing, using the CPU or the GPU, showed a difference of 2 vs. 53 seconds, and for processing an whole slide microscopy image, the difference was 81 seconds vs. almost 16 minutes. Source code, binary releases and test data can be found online on GitHub at https://github.com/smistad/FAST/.
Application of deep learning on histopathological whole slide images (WSIs) holds promise of improving diagnostic efficiency and reproducibility but is largely dependent on the ability to write computer code or purchase commercial solutions. We present a code-free pipeline utilizing free-to-use, open-source software (QuPath, DeepMIB, and FastPathology) for creating and deploying deep learning-based segmentation models for computational pathology. We demonstrate the pipeline on a use case of separating epithelium from stroma in colonic mucosa. A dataset of 251 annotated WSIs, comprising 140 hematoxylin-eosin (HE)-stained and 111 CD3 immunostained colon biopsy WSIs, were developed through active learning using the pipeline. On a hold-out test set of 36 HE and 21 CD3-stained WSIs a mean intersection over union score of 95.5 and 95.3% was achieved on epithelium segmentation. We demonstrate pathologist-level segmentation accuracy and clinical acceptable runtime performance and show that pathologists without programming experience can create near state-of-the-art segmentation solutions for histopathological WSIs using only free-to-use software. The study further demonstrates the strength of open-source solutions in its ability to create generalizable, open pipelines, of which trained models and predictions can seamlessly be exported in open formats and thereby used in external solutions. All scripts, trained models, a video tutorial, and the full dataset of 251 WSIs with ~31 k epithelium annotations are made openly available at https://github.com/andreped/NoCodeSeg to accelerate research in the field.
Treatment decisions for patients with presumed glioblastoma are based on tumor characteristics available from a preoperative MR scan. Tumor characteristics, including volume, location, and resectability, are often estimated or manually delineated. This process is time consuming and subjective. Hence, comparison across cohorts, trials, or registries are subject to assessment bias. In this study, we propose a standardized Glioblastoma Surgery Imaging Reporting and Data System (GSI-RADS) based on an automated method of tumor segmentation that provides standard reports on tumor features that are potentially relevant for glioblastoma surgery. As clinical validation, we determine the agreement in extracted tumor features between the automated method and the current standard of manual segmentations from routine clinical MR scans before treatment. In an observational consecutive cohort of 1596 adult patients with a first time surgery of a glioblastoma from 13 institutions, we segmented gadolinium-enhanced tumor parts both by a human rater and by an automated algorithm. Tumor features were extracted from segmentations of both methods and compared to assess differences, concordance, and equivalence. The laterality, contralateral infiltration, and the laterality indices were in excellent agreement. The native and normalized tumor volumes had excellent agreement, consistency, and equivalence. Multifocality, but not the number of foci, had good agreement and equivalence. The location profiles of cortical and subcortical structures were in excellent agreement. The expected residual tumor volumes and resectability indices had excellent agreement, consistency, and equivalence. Tumor probability maps were in good agreement. In conclusion, automated segmentations are in excellent agreement with manual segmentations and practically equivalent regarding tumor features that are potentially relevant for neurosurgical purposes. Standard GSI-RADS reports can be generated by open access software.