Joshua Doloff

Dr. Joshua Doloff


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2015 in Nature Materials
Verified
Journal Article
Open access
PDF file
OVOmid Veiseh
Omid Veiseh
JDJoshua Doloff
Joshua Doloff
MMMinglin Ma
Minglin Ma
AVArturo J. Vegas
Arturo J. Vegas
HTHok Hei Tam
Hok Hei Tam
DADaniel G. Anderson
Daniel G. Anderson
The efficacy of implanted biomedical devices is often compromised by host recognition and subsequent foreign body responses. Here, we demonstrate the role of the geometry of implanted materials on their biocompatibility in vivo. In rodent and non-human primate animal models, implanted spheres 1.5 mm and above in diameter across a broad spectrum of materials, including hydrogels, ceramics, metals and plastics, significantly abrogated foreign body reactions and fibrosis when compared with smaller spheres. We also show that for encapsulated rat pancreatic islet cells transplanted into streptozotocin-treated diabetic C57BL/6 mice, islets prepared in 1.5-mm alginate capsules were able to restore blood-glucose control for up to 180 days, a period more than five times longer than for transplanted grafts encapsulated within conventionally sized 0.5-mm alginate capsules. Our findings suggest that the in vivo biocompatibility of biomedical devices can be significantly improved simply by tuning their spherical dimensions.

30 September 2019 in Nature Biotechnology
Verified
Journal Article
Closed access
PDF file
LMLei Miao
Lei Miao
LLLinxian Li
Linxian Li
YHYuxuan Huang
Yuxuan Huang
DDDerfogail Delcassian
Derfogail Delcassian
JCJasdave Chahal
Jasdave Chahal
DADaniel G. Anderson
Daniel G. Anderson

25 January 2016 in Nature Medicine
Verified
Journal Article
Open access
PDF file
AVArturo J Vegas
Arturo J Vegas
OVOmid Veiseh
Omid Veiseh
MGMads Gürtler
Mads Gürtler
JMJeffrey R Millman
Jeffrey R Millman
FPFelicia W Pagliuca
Felicia W Pagliuca
DADaniel G Anderson
Daniel G Anderson
When encapsulated with alginate derivatives that resist the foreign-body response, human embryonic stem cell–derived beta cells restore long-term normoglycemia in immunocompetent mice without the need for immunosuppression. The transplantation of glucose-responsive, insulin-producing cells offers the potential for restoring glycemic control in individuals with diabetes1. Pancreas transplantation and the infusion of cadaveric islets are currently implemented clinically2, but these approaches are limited by the adverse effects of immunosuppressive therapy over the lifetime of the recipient and the limited supply of donor tissue3. The latter concern may be addressed by recently described glucose-responsive mature beta cells that are derived from human embryonic stem cells (referred to as SC-β cells), which may represent an unlimited source of human cells for pancreas replacement therapy4. Strategies to address the immunosuppression concerns include immunoisolation of insulin-producing cells with porous biomaterials that function as an immune barrier5,6. However, clinical implementation has been challenging because of host immune responses to the implant materials7. Here we report the first long-term glycemic correction of a diabetic, immunocompetent animal model using human SC-β cells. SC-β cells were encapsulated with alginate derivatives capable of mitigating foreign-body responses in vivo and implanted into the intraperitoneal space of C57BL/6J mice treated with streptozotocin, which is an animal model for chemically induced type 1 diabetes. These implants induced glycemic correction without any immunosuppression until their removal at 174 d after implantation. Human C-peptide concentrations and in vivo glucose responsiveness demonstrated therapeutically relevant glycemic control. Implants retrieved after 174 d contained viable insulin-producing cells.

25 January 2016 in Nature Biotechnology
Verified
Journal Article
Open access
PDF file
AVArturo J Vegas
Arturo J Vegas
OVOmid Veiseh
Omid Veiseh
JDJoshua Doloff
Joshua Doloff
MMMinglin Ma
Minglin Ma
HTHok Hei Tam
Hok Hei Tam
DADaniel G Anderson
Daniel G Anderson
In vivo screening of a large combinatorial library of alginates identifies materials that elicit a substantially reduced foreign body response. The foreign body response is an immune-mediated reaction that can lead to the failure of implanted medical devices and discomfort for the recipient1,2,3,4,5,6. There is a critical need for biomaterials that overcome this key challenge in the development of medical devices. Here we use a combinatorial approach for covalent chemical modification to generate a large library of variants of one of the most widely used hydrogel biomaterials, alginate. We evaluated the materials in vivo and identified three triazole-containing analogs that substantially reduce foreign body reactions in both rodents and, for at least 6 months, in non-human primates. The distribution of the triazole modification creates a unique hydrogel surface that inhibits recognition by macrophages and fibrous deposition. In addition to the utility of the compounds reported here, our approach may enable the discovery of other materials that mitigate the foreign body response.

21 June 2021 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
JDJoshua Doloff
Joshua Doloff
OVOmid Veiseh
Omid Veiseh
RMRoberto de Mezerville
Roberto de Mezerville
MSMarcos Sforza
Marcos Sforza
TPTracy Ann Perry
Tracy Ann Perry
RLRobert Langer
Robert Langer

20 March 2017 in Nature Materials
Verified
Journal Article
Open access
PDF file
JDJoshua Doloff
Joshua Doloff
OVOmid Veiseh
Omid Veiseh
AVArturo J. Vegas
Arturo J. Vegas
HTHok Hei Tam
Hok Hei Tam
SFShady Farah
Shady Farah
DADaniel G. Anderson
Daniel G. Anderson
Host recognition and immune-mediated foreign body response to biomaterials can compromise the performance of implanted medical devices. To identify key cell and cytokine targets, here we perform in-depth systems analysis of innate and adaptive immune system responses to implanted biomaterials in rodents and non-human primates. While macrophages are indispensable to the fibrotic cascade, surprisingly neutrophils and complement are not. Macrophages, via CXCL13, lead to downstream B cell recruitment, which further potentiated fibrosis, as confirmed by B cell knockout and CXCL13 neutralization. Interestingly, colony stimulating factor-1 receptor (CSF1R) is significantly increased following implantation of multiple biomaterial classes: ceramic, polymer and hydrogel. Its inhibition, like macrophage depletion, leads to complete loss of fibrosis, but spares other macrophage functions such as wound healing, reactive oxygen species production and phagocytosis. Our results indicate that targeting CSF1R may allow for a more selective method of fibrosis inhibition, and improve biomaterial biocompatibility without the need for broad immunosuppression.