Joonmyeong Choi

Dr. Joonmyeong Choi

Samsung Electronics

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2020 in Clinical Endoscopy
Verified
Journal Article
Open access
PDF file
Joonmyeong ChoiJoonmyeong Choi
Joonmyeong Choi
KSKeewon Shin
Keewon Shin
JJJinhoon Jung
Jinhoon Jung
HBHyun-Jin Bae
Hyun-Jin Bae
AKASAN MEDICAL CENTER Kim
ASAN MEDICAL CENTER Kim
Namkug KimNamkug Kim
Namkug Kim
Recently, significant improvements have been made in artificial intelligence. The artificial neural network was introduced in the 1950s. However, because of the low computing power and insufficient datasets available at that time, artificial neural networks suffered from overfitting and vanishing gradient problems for training deep networks. This concept has become more promising owing to the enhanced big data processing capability, improvement in computing power with parallel processing units, and new algorithms for deep neural networks, which are becoming increasingly successful and attracting interest in many domains, including computer vision, speech recognition, and natural language processing. Recent studies in this technology augur well for medical and healthcare applications, especially in endoscopic imaging. This paper provides perspectives on the history, development, applications, and challenges of deep-learning technology.

1 September 2021 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
Joonmyeong ChoiJoonmyeong Choi
Joonmyeong Choi
SCSungman Cho
Sungman Cho
JCJONG WOO CHUNG
JONG WOO CHUNG
Namkug KimNamkug Kim
Namkug Kim

1 August 2018 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
PDF file
Jung-Hoon ParkJung-Hoon Park
Jung-Hoon Park
WKWoo Seok Kang
Woo Seok Kang
KKKun Yung Kim
Kun Yung Kim
BKByung-Chul Kang
Byung-Chul Kang
JPJun Woo Park
Jun Woo Park
HSHo-Young Song
Ho-Young Song

1 February 2020 in Lymphatic Research and Biology
Verified
Journal Article
Closed access
ZWZhe Wang
Zhe Wang
KKKun Yung Kim
Kun Yung Kim
SYSung Hwan Yoon
Sung Hwan Yoon
JPJung-Hoon Park
Jung-Hoon Park
Joonmyeong ChoiJoonmyeong Choi
Joonmyeong Choi
JJJae Yong Jeon
Jae Yong Jeon
Background: Radiation therapy has been applied to prolong the duration of lymphedema. This study aimed to evaluate the effect of radiation on the development of lymphedema in a mouse hindlimb model. Methods and Results: A total of 24 Balb/c mice underwent the right popliteal lymph node excision and the afferent and efferent lymphatics blockage. The radiation group (n = 12) received a single 20 Gy radiation 1 day before surgery in the right hindlimb of each mouse, whereas the control group (n = 12) only received surgery without radiation. The right hindpaw thickness of each mouse was measured twice a week for 4 weeks. Fluorescence microscopy images using fluorescein isothiocyanate–dextran tracer were obtained once weekly. Immunohistochemical (IHC) staining images using anti-lymphatic vessel endothelial hyaluronan receptor-1 (anti-LYVE-1) were obtained at 4 weeks after surgery. The radiation group showed significant increase in the thickness of the right hind paws from 0.5 to 2 weeks compared with the control group. As for fluorescence lymphography, the radiation group showed a lower number of regenerated lymphatics and more congestion of tracers in the operated limb at the surgery sites at 1, 2, 3, and 4 weeks after surgery. For the IHC analysis, the radiation group showed a lower number of regenerated lymphatics per high-power field at the surgery site than the control group. Conclusion: Radiation therapy transiently aggravated the extent of lymphedema by inhibiting regenerated lymphatics in a mouse hindlimb model. However, it did not prolong the duration of lymphedema because the cutaneous interstitial flow contributes to the lymphatic fluid clearance.

1 June 2019
Verified
Conference Paper
Closed access
HYHye Ju Yoo
Hye Ju Yoo
WKWoongbae Kim
Woongbae Kim
SLSang-Yoep Lee
Sang-Yoep Lee
Joonmyeong ChoiJoonmyeong Choi
Joonmyeong Choi
YKYoun Joo Kim
Youn Joo Kim
KCKyu-Jin Cho
Kyu-Jin Cho
Lymphedema is a non-curative chronic swelling caused by impairment of the lymphatic system, affecting up to 250 million patients worldwide. The patients suffer from low quality of life because of discomfort and reduced range of motion due to the swelling. Severe swellings can be immediately mediated with special massaging technique known as the Manual Lymphatic Drainage (MLD). Limitations of MLD involves long travel distances, the cost of regular treatment sessions, and the lack of lymphedema specialists. Since MLD is performed very gently, described as caressing a baby's head, soft wearable robotics with its inherent compliance and safety is the perfect solution to creating a light and safe wearable lymphedema massaging device. In this paper, origami-inspired soft fabric pneumatic actuator is developed that creates not only normal force, but also shear force which is essential in the performance of MLD. The shear is created by the unfolding of the Z-shaped fold-lines as the actuator is inflated. One Z-folded actuator module of 30 x 60 mm dimension with a single fold of 15 mm fold height creates maximum shear force of about 1.5 N and stroke displacement of about 30 mm when subjected to compression loading of 5 N. The range of forces exerted can be tuned by varying the tension of the compressive clothing covering the actuators, and the stroke displacement can be varied by changing the parameter of the actuator module itself, such as the fold height and the number of the folds. The modules can also be repeatedly actuated under compressive clothing, and therefore, the developed actuator modules have high potential as a wearable massaging device.

5 July 2011 in International Journal of Automation Technology
Verified
Journal Article
Closed access
JLJun Li
Jun Li
Joonmyeong ChoiJoonmyeong Choi
Joonmyeong Choi
KKKenji Kawashima
Kenji Kawashima
TFToshinori Fujita
Toshinori Fujita
TKToshiharu Kagawa
Toshiharu Kagawa
In this paper, integrated control design for the pneumatic servo table system considering the dynamics of pipelines and servo valve is studied. The table is mainly composed by a pneumatic actuator, a highperformance pneumatic servo valve and pipelines. The pneumatic actuator utilizes a pneumatic cylinder with air bearings. The servo valve has high dynamics up to 300 Hz and is connected to the pneumatic actuator by pipelines. The system is pneumatically driven, providing the advantages of low heat generation and non-magnetic, nature suited to precise positioning. To simulate the system, we designed a linear model considering pipelines and servo valve dynamics. Comparison results showed that with a 7thorder linear model, the discrepancy between experiment and simulation results was much smaller than when using a 3rdorder model. The model’s complexity made it necessary to reduce the model’s order. Two poles are much further from the imaginary axis compared with other five poles in the pole loci of the 7thorder model, so the model is reduced to a 5thorder. A comparison of simulation and experiment results showed that the 5thorder model matches the real system well.