Deposition of aerosols in the respiratory system depends inter alia on their size and the respiratory tract deposition is appreciable for nanometer-sized particles. This article presents the results of measurements of size distributions of aerosols in the range of several nanometers up to about 20 μm in the underground mine excavations of an active hard coal mine. The study included practically all particles of a respirable fraction. The results showed that a high concentration of fine and ultrafine aerosols occurs in key underground workplaces especially during mining machine operations, although their contribution to total mass concentration is usually negligible.
The equilibrium factor F is one of the parameters that should be considered when assessing the effective dose based on radon activity concentration. Since the equilibrium factor in various environments ranges theoretically from a value close to 0 to 1, it is expected that dose assessment based on one recommended coefficient value may lead to an underestimation or overestimation of the dose. That is why it is essential to measure this quantity if the basis for dose assessment is the radon concentration and not the concentration of radon decay products. The equilibrium factors were determined based on measurements of radon activity concentration and potential alpha energy concentration and varied from 0.15 to 0.94, with an arithmetic mean of 0.55. The average effective dose calculated for the employee taking into account these values was 31 mSv, assuming an annual working time of 1800 h. In turn, the average effective dose calculated for the equilibrium factor of 0.2 as recommended by the International Commission on Radiological Protection (ICRP) was equal to 13 mSv.
The article presents a model for simulating changes in the activity concentration of radon and thoron as well as their progeny in closed or poorly ventilated systems. A system can be considered closed when a stream of radon and thoron flows into a space, but nothing comes out. It was also assumed that there may be devices or installations with a filtering system that would reduce the concentration of radon and thoron decay products. These assumptions may, therefore, correspond to a situation in which, in an isolated chamber, the calibration of radon hazard-monitoring devices is carried out, and nuclides are supplied from an emanation or flow through sources or well-isolated spaces in an environment where the source of nuclides is, for example, radon and thoron exhalation. The differential equations were formulated on the basis of the assumption that the activity concentration of radionuclides of concern in the space is uniform. The equations do not consider possible losses due to diffusion or the inertial or gravitational deposition of aerosols. If these phenomena have a limited impact on changes in the activity concentration of nuclides, the solutions provided may be used to simulate the activity concentration of radon and thoron and their decay products in any confined space assuming different boundary conditions.
1 August 2021 in Journal of Environmental Radioactivity